Netaji Subhas Institute Of Technology Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Netaji Subhas Institute Of Technology - NSIT Tender
Electrical and Electronics
Eprocure
Opening Date13 Aug 2019
Closing Date23 Aug 2019
Tender Amount₹ 56,77,972 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 1,13,559Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_NSIT_178127_1Bid Award Id
ViewTender No
NIT No 21/VC/19-20/NSUTTender Authority
Netaji Subhas Institute Of Technology ViewPurchaser Address
-Website
http://http://www.nsit.ac.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
1.4 14 Hp Outdoor Unit (Cooling Only)
1
-
346920
... More
2 Supply, Installation Testing and commissioning of floor mounted DX Type indoor unit having higher air quantity and higher static with multispeed fan , filter complete in all respects integrable with ODUs etc. of Vertical type having minimum of 3 Row with minimum ESP 80 pascals Static with DX Coil suitable to match with VRF Outdoor Units. The quoted price should be inclusive of Kit and Remote controller. Make:- (Blue star, Daikin, Toshiba, Mitsubishi, O' General, Zeco, Waves, Edgetech).
2.1 15.0 Tr and 6000 CFM Floor mounted indoor unit as per specifications
4
-
141830
... More
2.2 10.0 Tr 4000 CFM Floor mounted indoor unit as per specifications
2
-
105300
... More
3 Refrigerant Piping Supply Installation and Testing of Interconnecting refrigerant copper pipe work of suitable size with 13/19mm insulation of closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the building shall be properly supported on cable tray and all external piping should run in covered cable trays upto the satisfaction of engineer in-charge.
3.1 28.6 mm O.D. (insulation : 19 mm)
72
-
1333
... More
3.2 15.9 mm O.D. (insulation : 19 mm)
48
-
684
... More
3.3 12.7 mm O.D. (insulation : 19 mm)
24
-
496
... More
4 Drain Piping Supply Installation Testing and Commissioning Providing and fixing rigid PVC piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation. 4.1 32 mm
28
-
180
... More
5 Supply Installation Testing and Commissioning of Fire Retardant Canvas Connection.
6
-
2500
... More
6 Control & Transmission Wiring Supply Installation Testing and Commissioning of control cum transmission wiring of 2 core x 0.75 sq mm copper or as recommended by OEM in suitable PVC conduits between indoor and outdoor units.
93
-
150
... More
7 Providing & fixing of weather-Proof Isolator for Indoor & Outdoor near the unit.
7.1 63 Amp 4 Pole or as recommended by OEM
4
-
4000
... More
7.2 32 Amp 4 Pole or as recommended by OEM
2
-
3500
... More
8 Supply, laying, testing and commissioning of power cabling from mcb to indoor and outdoor unit, as per Standard specification. Power Cabling should be PVC insulated and PVC sheathed, armoured, Cooper Conductor of 1.1 KV grade. Power cable shall be properly supported on cable trays up-to the satisfaction of engineer in-charge. 8.1 4C x 10 Sq mm or size as recommended by OEM
67
-
560
... More
8.2 4C x 6 Sq mm or size as recommended by OEM
33
-
390
... More
8.3 4C x 4 Sq mm or size as recommended by OEM
23
-
290
... More
9 Supply Installation Testing and Commissioning of GI Perforated Type Cable Trays covered from top for exposed copper piping and power cabling with GI Sheets of 18 Gauge.
9.1 150 mm
58
-
690
... More
10 Supply, Installation, Testing and commissioning of 2 Tr Tower AC suitable to operate on 1 Phase/ 3Phase power supply, with air-cooled evaporator with coil, fan, and fan motor, air-cooled condenser with hermetically sealed scroll compressor with suitable refrigerant, condenser coil, propeller fans controls, including control wiring, cordless remote. The quoted price shall be inclusive of interconnected insulated refrigerant piping, insulated drain piping, vibration isolation pads / vibration isolators and associated electrical cabling & earthing between indoor & outdoor units and MS powder coated base frame work made of angle iron for mounting of outdoor / indoor units complete in all respects required for proper function of units etc. tothe satisfaction of the engineer in charge. Make:- (Blue star, Daikin, Toshiba, Mitsubishi and O' Genral)
2
-
100000
... More
11 Supply, Installation, testing & commissioning of Window AC of 1.5 TR capacity suitable to operate from 230+10% volt, 50 HZ, with suitable star rating and refrigerant gas 1 phase power supply with cordless remote control, fittings & required cable to connect unit to socket. Installation and commission of unit to be complete in all respect with satisfaction of engineer-in- charge including 5 KVA automatic voltage stabilizer Make:- (Blue star, Daikin, Toshiba, Mitsubishi and O' Genral)
2
-
39000
... More
12 Civil Works Necessary civil works of making opening and finishing them as required. Cutouts for refrigerant pipes of required size, making good the same to the satisfaction of the engineer in charge.
1
-
20000
... More
13 Comprehensive Annual Maintenance of all VRV/VRF Package type AC system, vertical type AC 2 TR and window type AC 1.5 TR provided under this contract, after Defect Liability Period of One Year. i) 20 HP outdoor units (Heating & Cooling) 01Nos.
ii) 14 HP outdoor units (Heating & Cooling) 01Nos.
iii) 20 HP outdoor units (Cooling only) 03 Nos.
iv) 14 HP outdoor units (Cooling only) 01 Nos.
v) 15 TR Floor mounted indoor unit 04 Nos.
vi) 10 TR Floor mounted indoor unit 02 Nos.
vii) Vertical AC unit 2 TR complete with copper piping, electric connection etc. as required 02 Nos.
viii) Window type AC 1.5 TR 02 Nos. Note:- Copper piping, electrical connection, drain piping etc. complete are including in the above work. First Year
1
-
302400
... More
Second Year
1
-
323568
... More
Third Year
1
-
346218
... More
Fourth Year
1
-
370453
... More
Fifth Year
1
-
396385
... More
Deduct - 14 Dismantling & Buyback of existing Blue Star make 15.0 Tr x 4 nos. and 10.0 Tr x 2 nos air cooled package units outdoor and indoor units complete with copper piping, wiring , control panel etc. except the duct which shall not be dismantled and shall be used for new AC plants.
1
-
60000
... More
15 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.
(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) a) 4 way (4 + 12), Double door
4
-
4502
... More
16 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. a 100 A, 16 kA,TPMCCB
4
-
3218
... More
17 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a Triple pole and Neutral
8
-
891
... More
Supplying and fixing following rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
a) 63 A TP
4
-
1334.92
... More
18 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
246
-
23
Evaluation Notes How It Works ?