Netaji Subhas Institute Of Technology Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Netaji Subhas Institute Of Technology - NSIT Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date3 May 2023
Closing Date10 May 2023
Tender Amount₹ 39,66,312 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
4 Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987,Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. With semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles.

297

502063

1690.45

... More
5 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level :Cement mortar 1:4 (1 cement :4 coarse sand)

12

12216

1018.05

... More
6 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand)

50

14742

294.85

... More
7 15 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement: 4 fine sand)

60

20382

339.7

... More
8 Providing and fixing soil, waste and vent pipes :100 mm dia Sand cast iron S&S as per IS - 1729

61

62101

1018.05

... More
9 Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes : 100 mm dia pipe

32

5230

163.45

... More
10 Providing and fixing M.S. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter : For 100 mm dia pipe

6

771

128.65

... More
11 Providing and fixing plain bend of required degree 100 mm dia Sand cast iron S&S as per IS - 1729

8

3303

412.95

... More
12 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :100 mm inlet and 100 mm outlet and cast iron S&S as per IS: 3989

2

3208

1604.1

... More
13 Providing and fixing collar :100 mm Sand cast iron S&S as per IS - 1729

10

3996

399.6

... More
14 Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 100 mm dia

4

2462

615.7

... More
15 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting,of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete

2

26073

13036.55

... More
16 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 250 mm diameter

1

683

683.7

... More
17 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls 25 mm nominal dia Pipes

8

5008

626.05

... More
15 mm nominal dia Pipes

12

5293

441.15

... More
18 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charg

2

598

299.35

... More
19 Providing and fixing toilet paper holder C.P. Brass

2

1361

680.8

... More
20 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

28

19672

702.6

... More
21 Providing and fixing to existing door frames.30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.

12

41961

3496.75

... More
22 Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge. 200 mm

4

612

153.15

... More
23 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete :250x16 mm

2

331

165.9

... More
Providing and fixing ISI marked 85x42 mm oxidised M.S. pull bolt lock conforming to IS : 7534 with necessary screws bolts, nut and washers etc. complete

2

217

108.65

... More
25 Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100x100x100 mm Sand cast iron S&S as per IS - 3989

4

2925

731.4

... More
26 Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge. For door/ window/ clerestory window

4

4187

1046.95

... More
27 Providing and fixing in position Stainless steel Grade 304 plate-1.0 mm thick as per design for expansion joints.300 mm wide.

11

11587

1053.4

... More
28 Providing and laying in floors superior class 20 mm thick v groove Synthetic rubber tiles using good quality reputed make synthetic rubber adhesive @ 150 ml/sqm all complete in required color and sizes as per complete satisfaction of the Engineer-In-chrge. Note: The rubber tile samples will be approved by the Engineer-in-Charge before the start of the work.

50

77423

1548.47

... More
29 Providing and fixing PTMT bib cock of approved quality and colour.15mm nominal bore, 86 mm long, weighing not less than 88 gms

2

219

109.85

... More
30 Providing and fixing PTMT stop cock of approved quality and colour 15 mm nominal bore, 86 mm long, weighing not less than 88 gms

4

412

103.15

... More
31 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore

2

1000

500.35

... More
32 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete

21

17982

856.3

... More
33 Providing and fixing aluminium hanging floor door stopper, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete Twin rubber stopper

25

1556

62.25

... More
34 Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete.

215

89784

417.6

... More
35 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.

334

6963

20.85

... More
36 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer

334

21526

64.45

... More
37 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification.Two or more coats on new work

334

30978

92.75

... More
38 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

334

41365

123.85

... More
Electrical Work (Part-II) SH-01 (WIRING AND ACCESSORIES) 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. a Group A

20

20300

1015

... More
2 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. a Group A

110

63140

574

... More
3 Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin , 5/6 A, 15/16 Amps modular socket outlet and 15/16 Amps modular switch , connection etc. as required .

23

13478

586

... More
4 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel conduit as required a) 3 x 1.5 sq. mm

100

9500

95

... More
b) 3 x 2.5 sq. Mm

50

6850

137

... More
c) 3 x 4 sqmm

80

16480

206

... More
5 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required

70

23380

334

... More
6 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 5/6 A switch

120

12360

103

... More
b) 3 pin 5/6 A socket outlet

20

2440

122

... More
c) 15/16 A switch

5

780

156

... More
d) 6 pin 15/16 A socket outlet

5

985

197

... More
e) 2 way 5/6 A switch

10

1480

148

... More
7 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

40

14760

369

... More
8 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. a) 1 or 2 Module

5

665

133

... More
b) 3 Module

20

3020

151

... More
c) 6 Module

10

1820

182

... More
d) 8 Module

10

2110

211

... More
e) 12 Module

6

1632

272

... More
9 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole

15

3840

256

... More
b) Single pole and neutral

4

2396

599

... More
10 Supplying and fixing TPN MCB 63 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required

4

7997

1999.35

... More
11 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.00, Air delivery minimum 210 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.

40

109200

2730

... More
12 Dismantling the existing worn out / defective fittings from the ceiling and SITC of LED surface/wall batten fitting minimum 20 watt with Aluminium housing and integrated electronic driver system efficacy minimum 100 lumen/watt LM79, color temp 6500 deg K as per required.

22

12290

558.64

... More
13 Dismantling the existing worn out / defective fittings from the ceiling and SITC of minimum 36 watt Aluminium slim energy efficient LED Panel light fitting having system efficacy minimum 100 lumen/watt LM79, color temp 6500 deg K, recess mounting suitable for fitting in the 600mm x 600mm square existing space having symmetric glare free illumination in the false ceiling,complete with all standard accessories including drivers etc. complete as required

56

214107

3823.35

... More
14 Suppling and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess inculding cutting the wall and making good the same in case of recessed conduit as required. 25MM PVC Conduit

50

7250

145

... More
AIR CONDITIONING SupplyInstallation,Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume aircooled Outdoor units suitable for cooling and heating,having all hermetically sealed inverter type Scroll Compressor(s),minimum two compressors for above 14HP modules, microprocessor based Controller,top discharge type condensing unit(s),with R410A Refrigerant,vibration isolators,with suitable foundation etc. complete as required.The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping.The unit shall be suitable to work on 400V+/-10%,3Phase,50Hz AC power supply.The unit shall be filled with first charge of the refrigerant and ready for use as required.The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 .(ODU Unit should be anti corrosive coated from factory) 30

30

492450

16415

... More
16 Supply,installation,testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/ dynamically balanced blower, multi speed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cordless remote control, drain pan, necessary accessories etc. suitable for operation on 230V±10%, 50Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. a) 2 TR

10

221000

22100

... More
b) 1.45 TR

2

42630

21315

... More
c) 1 TR

1

19700

19700

... More
17 Supply,Installation,testing & commissioning of Y Joints forIDU's

11

43164

3924

... More
18 Supply,Installation,Testing & commissioning of Central Remote Controller for controlling the all IDU's & ODU's

2

48364

24182

... More
19 Supply,Installation,testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system,complete withfittings,with suitable adjustable ring type hanger supports,jointing/brazing including accessories,insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometricnitrile rubbe rtubular sleeves sections of specified thickness as given below for Suction and Liquid lines,all accessories as per specifications etc. as required : a) 28.58 mm O.D. (Hard drawn)with tube thickness 1.2mm with 19 mm thick insulation

38

42104

1108

... More
b) 25.4mmdia(OD)(Harddrawn)withtubethickness1.2mmwith19mm thick insulation

24

24528

1022

... More
c) 22.2 mm O.D. (Hard drawn)with tube thickness 1.2mm with 19 mm thick insulation

24

20760

865

... More
d) 19 mm O.D. (Hard drawn)with tube thickness 1.2mm with 19 mm thick insulation

21

14847

707

... More
e) 15.86 mm O.D. (Soft drawn)with tube thickness 1.2mm with 19 mm thick insulation

24

14112

588

... More
f) 12.7 mm O.D. (Soft drawn)with tube thickness 1.2mm with 19 mm thick insulation

24

11184

466

... More
g) 9.5 mm O.D. (Soft drawn)with tube thickness 1.2mm with 19 mm thick insulation

27

8937

331

... More
h) 6.4 mm dia(OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation

15

3675

245

... More
20 Supply Installation Testing and Commissioning Providing and fixing rigid PVC piping complete with fittings, supports as per specifications and duly insulated with 9 mm thick closed cell nitrile rubber insulation. a) 25 mm

200

25000

125

... More
21 Cutting holes of required size in brick masonry wall for passing of copper pipes, Drain pipes, cable removing of false ceiling and re-fixing/placing back if required etc. and making good the same etc. complete as per direction of Engineer-in-charge.(The hole shall be made by core cutter)

10

2404

240.4

... More
22 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

220

51260

233

... More
23 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. a) 300 mm width X 50 mm depth X 1.6 mm thickness

22

21186

963

... More
24 Supply of XLPE insulated Copper conductor, armoured 1.1 KV grade cable of following size complete as required. a) 4C x 6sqmm

10

5128

512.86

... More
b) 4C x 10sqmm

10

8164

816.48

... More
c) 4C x 25sqmm

45

83110

1846.91

... More
25 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.

90

4590

51

... More
26 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. a) Upto 35 sq. mm (clamped with 1mm thick saddle)

85

3825

45

... More
27 Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a) 4 X 10 sq. mm (25mm) or 4 X 6 sq. mm

4

1076

269

... More
b) 4 X 25 sq. mm (28mm)

2

630

315

... More
28 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCBTPDB is normally used where 3 phase outlets are required.) a) 8 Way (4+24),Double door

1

10165

10165

... More
29 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. a) 125 A, 16 KA,TPMCCB (Incomer to Vertical DB)

1

4821

4821

... More
30 SITC of 2.0 Tr capacity Split type air conditioner, 3 star rated Non Inverter type having cooling facility suitable for operation of 215±10% volt, 50 HZ, A.C supply with ecofriendly gas having cordless remote control, fittings & required one copper conductor cable to connect unit to socket out with 3 pin 25 amp plug top. Installation and commission of unit to be complete in all respect with satisfaction of engineer-in- charge.Completed with upto 3 mtr refrigerant pipe and copper conductor cable of suitable size duly insulated with nitrile rubber tubular insulation between each set of indoor & outdoor units including making hole in the wall with the help of core cutter including repairing etc as per specification.(Note: The outdoor unit & indoor unit shall have copper coil for condenser and evaporater. The work shall be completed as per the scope of work, terms & conditions and the Directions of Engineer-in-charge.)

3

167774

55924.73

... More
31 SITC of 1.5 Tr capacity Split type air conditioner, 3 star rated Non Inverter type having cooling facility suitable for operation of 215±10 % volt, 50 HZ, A.C supply with eco friendly gas having cordless remote control, fittings & required one copper conductor cable to connect unit to socket out with 3 pin 25 amp plug top. Installation and commission of unit to be complete in all respect with satisfaction of engineer-in- charge.Completed with upto 3 mtr refrigerant pipe and copper conductor cable of suitable size duly insulated with nitrile rubber tubular insulation between each set of indoor & outdoor units including making hole in the wall with the help of core cutter including repairing etc as per specification..(Note: The outdoor unit & indoor unit shall have copper coil for condenser and evaporater. The work shall be completed as per the scope of work, terms & conditions and the Directions of Engineer-in-charge.)

3

133308

44436.23

... More
32 Supplying, Installation and welding the copper pipe with the existing pipe of 1.5/2 TR refrigerant copper pipe work with fitting duly insulated with 19/13 mm thick closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specification all piping inside the room shall be properly supported with M. S. hanger / angles / clamping arrangement, dash fasteners suitably run on existing cable tray etc. as required.

30

32466

1082.21

... More
33 SITC of 2 TR /1.5 TR AC Outdoor unit powder coated stand with required as per site condition wall mounted / Floor Mounted.

6

5305

884.24

... More
34 Supplying and Laying of one number 3 core 1.5/2.5 sqmm pvc insulated and pvc sheathed round wire on wall/surface/with refrigerant pipe etc for AC.

48

4107

85.58

... More
35 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.

6

4362

727

... More
36 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop arthing as required.

50

21650

433

... More
37 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

2

14944

7472

... More
38 Comprehensive Annual Maintenance of 2/1.5 Tr capacity Inverter type/Non Inverter Type Split AC as per manufacturer recommendation including servicing of the AC ,Refrigerant gas charging , replacement of compressor, motor,wiring,etc complete with all parts required for healthy and proper functioning of the Air Conditioning.(Nothing will be provided by the department during the period) a) Year 1 (after Defect Liability Period of One Year)

6

18000

3000

... More
b) Year 2

6

19440

3240

... More
c) Year 3

6

20994

3499

... More
d) Year 4

6

22674

3779

... More
e) Year 5

6

24486

4081

... More
39 Comprehensive Annual maintenance of VRV/VRF Air conditioning system provided and installed under this contract with all parts/components i.e compressor,gas charging,fan motor etc(one year free defect liability period and thereafter paid) a) For 1st Year (During defect liability period)

30

-

-

... More
b) For 2nd Year

30

84000

2800

... More
c) For 3rd Year

30

88200

2940

... More
d) For 4th Year

30

92610

3087

... More
e) For 5th Year

30

97200

3240

... More
f) For 6th Year

30

102060

3402

... More
40 Dismantling & Buy Back of old & defective following items as per required. a) 4 x 1 Light fitting.

20

-2000

100

... More
b) Ceiling Fans

40

-20000

500

... More
c) Fluorescent Tube light

54

-2700

50

... More
d) 2X2 Recess Fluorescent light

4

-600

150



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.