National Security Guard Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 39,224Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_NSG_807563_1Bid Award Id
ViewTender No
20/SC(Engg)/NSG/2024-25Tender Authority
National Security Guard ViewPurchaser Address
-Website
http://https://www.nsg.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Repair/ maintenance and Calibration of 11 KV C.T.’s for Protection and metering of 11 KV H.T. Panel and also checking of tripping system with Primary Injection Test method. as per direction of engineer in charge
4
10140
2535
Repair / maintenance and healthiness testing of H.T. P.T.,including Checking of Insulating Resistance Value of P.T. and also checking of tripping system with Primary Injection Test method (During the shut down period). As per direction of engineer in charge
2
3662
1831
Repair / maintenance and complete Servicing of L.T. A.C.B.’s, of ratings 1600 Amp. or 1250 Amp.or 800 Amp.or 1000 Amp.including cleaning of arcing chutes, arcing contacts, isolated contact,all fixed and moving contacts, auxiliary contacts ,cleaning, lubricating the tripping & closing mechanism and also free movement of guide channels. etc (During the Shut-Down Period) as per direction of engineer in charge
6
25356
4226
Repair / maintenance with Checking, Testing of 200 KVAR Capacitor Bank Panel including checking/ testing of Automatic Power Factor Control Relay Healthiness Testing of Capacitor, Contactors, fuses & control wiring of Capacitor Panel. as per direction of engineer in charge
2
19720
9860
Repair, maintenance , general Servicing and Checking of Transformer 11 KV/415 V, 630 KVA ,complete internal/external cleaning, tightening of all joints, Checking/ Measuring the Insulation Resistance Value of HT & LT winding of Transformer & H.T. Cable with H.T./L.T. Megger.earthing resistance of all earthing connected with the Transformer (During the Shutdown Period) ,complete in all respect as per direction of engineer in charge
2
14086
7043
Repair/ maintenance of H.T. O.C.B. , Checking, Oiling, greasing of the mechanical system , testing the Insulation Resistance Value of Breaker with HT Megger (During the shut down period). Complete in all respect as per direction of engineer in charge
2
8452
4226
Supplying/ Installation / Testing and commissioning Transformer Protection relay having LED display, 90-270 VAC/DC . Make Power Electronic & Control, TR-7570 including dismantling of the old relay and aink required connection with the new relay as per direction of engineer in charge
2
53010
26505
Fabrication, S/I/T/C of powder coated Cubical type, out door double door electrical panel of required size having depth 300 mm made out of 14 SWG CRCA sheet, having 250 Amps, 04 nos. insulated aluminium Bus bars, Providing & fixing angle iron frame of size 1100 mm (L) x 300 mm (W) and having 500 mm long 04 legs, made out of 45 mm x 45 mm & 5 mm thick angle iron grouting the same in suitable cement concrete foundation, arrangement for incoming/outgoing cabling including earthing, locking, interconnection, etc. as required.
4
100692
25173
SITC of 250 A with 3 pole pole, 36 KA breaking capacity,Ics=%Icu 100%, MCCB make L&T to be fixed directly on existing electrical panel this include dismantling of faulty existing fitted MCCB cable etc and after making all good desired modification/fixing/ thimbling etc complete in all respect as per direction of engineer in charge. Make L&T Model DN2-250D (Dismantelled material will be retained by agency )
1
30413
30413
SITC of 160 A with 3 pole pole, 36 KA breaking capacity,Ics=%Icu 100%, MCCB make L&T to be fixed directly on existing electrical panel this include dismantling of faulty existing fitted MCCB cable etc and after making all good desired modification/fixing/thimbling etc complete in all respect as per direction of engineer in charge.(Dismantelled material will be retained by agency ). Make L&T Model DZ1-160D or DN2-250D / havells
2
47252
23626
SITC of 100 A with 3 pole pole, 36 KA breaking capacity,Ics=%Icu 100%, MCCB make L&T to be fixed directly on existing electrical panel this include dismantling of faulty existing fitted MCCB cable etc and after making all good desired modification/fixing/thimbling etc complete in all respect as per direction of engineer in charge.Make L&T Model DZ1-160D or DN2-250D / havells
9
115902
12878
S/I/T/C spreader terminals suitbale for DZ-1- 160 - 3 pole MCCB in the existing cubical panels i/c making electrical connection etc. as required. Make Havells/ L&T Model DZ-1- 160 - 3 pole
10
19720
1972
S/I/T/C spreader terminals suitbale for DN2-250- 3 Pole MCCB in the existing cubical panels i/c making electrical connection etc. as required. Make Havells/ L&T Model DN2-250- 3 Pole
1
2093
2093
SITC of Digital Voltmeter in the existing electrical panel including connection etc as required (Make: Conzerv/AE/L&T)
4
4908
1227
SITC of Digital Ammeter in the existing electrical panel including connection etc as required (Make: Conzerv/AE/L&T)
4
4908
1227
SITC of Voltmeter Selector Switch in the existing electrical panel including connection etc as required (Make: Conzerv/AE/L&T)
4
1156
289
SITC of Ammeterr Selector Switch in the existing electrical panel including connection etc as required (Make: Conzerv/AE/L&T) (Make: Kaycee/Salzer/L&T)
4
1156
289
SITC of 200/5 Amp CT's Cast resin type in the existing electrical panel including connection etc as required (Make: Matrix/AE/L&T)
6
2832
472
SITC LED Indication Light ( R/Y/B clour as required) in the existing electrical panel including connection etc as required (Make: Conzerv/AE/L&T)
60
16500
275
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
8
59776
7472
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
90
21960
244
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
502
35140
70
Painting of exposed portion of electrical panels with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade. One or more coats on old work
200
26000
130
Lettering with black Japan paint of approved brand and manufacture.
4000
20200
5.05
Supplying and laying of 40 MM HDPE pipe ISI marked wall thickness 4 mm along with all accessories like socket, bend, couplers etc. complete with fitting and cutting, jointing etc.direct in ground/ sheddling on wall , complete as required
400
56400
141
Supplying and Laying one number XLPE insulated and PVC sheathed aluminium armoured power cable of 1.1 KV grade of size 2 x 16 sqmm in the existing RCC/ HUME/ METAL/HDPE pipe as required. Make havells/ Polycab
449
131108
292
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal)
250
61750
247
90 mm dia (OD-90 mm & ID-76 mm nominal)
200
58000
290
Supplying and making straight through joint with heat
shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 16 sq. mm or 2 X 25 sq. mm or 2 X 35 sq. mm as required
4
8672
2168
3½ X 25 sq. mm or 3½ X 35 sq. mm
4
9912
2478
3½ X 70 sq. mm
4
13452
3363
3½ X 95 sq. mm
4
14068
3517
3½ X 120 sq. mm or 3½ X 185 sq. mm
4
18152
4538
3½ X 240 sq. mm
2
9838
4919
3½ X 300 sq. mm
2
12214
6107
Supplying and Laying one number XLPE insulated and PVC sheathed aluminium armoured power cable of 1.1 KV grade of size 3.5x35 sqmm in the existing RCC/ HUME/ METAL/HDPE pipe as required
200
126000
630
Supplying and Laying one number XLPE insulated and PVC sheathed aluminium armoured power cable of 1.1 KV grade of size 3.5x70 sqmm in the existing RCC/ HUME/ METAL/HDPE pipe as required
200
223200
1116
S/I/T/C of powder coated Cubical type panel ( Joint Box) made out of 14 SWG CRCA sheet, of size 500 mm x 500 mm x 250 mm deep having 200 Amps, 04 nos. insulated aluminium Bus bars, Providing & fixing angle iron frame of size 500 mm (L) x 250 mm (W) and having 400 mm long 04 legs, made out of 45 mm x 45 mm & 4 mm thick angle iron grouting the same in suitable cement concrete foundation, arrangement for incoming/outgoing cabling including making connection with the incomming and outgoing power supply , earthing, locking, interconnection, etc. as required. ( min Qty of Cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size should be 0.16 Cm M )
2
20022
10011
Tracing/locating and pinpointing of cable faults in the existing underground cable with the help of electrical fault location device including cartage of machine to and fro, tracing fault along with the route of the cable etc. as required.
8
63920
7990
Excavation/digging of earth/CC/pucca flooring up to depth of cable and around the location of fault traced of the underground cable, cutting of cable, meggering and checking of type of fault including refilling the excavated area complete in all respect as required.
8
13024
1628
Moling work under the Road for crossing UG Electrical cable at the depth of 75 cm including getting out the excavated soil/ CC and disposal of excavated soil as directed within a lead of 50 metres.
10
28890
2889
Supplying Installation, Testing and commissioning 100 watt LED street Light with IP65/IP66 Protection made of pressure die cast aluminium housing with toughened glass and high power LED and secondary lances directly on pole / lighting bracket including connection with 1.5 Sq mm FRLS PVC insulated copper conductor single core cable and earthing etc as required. Make Havells/ Phillips/ Crompton / Standard
20
244160
12208
Supplying and fixing of SMC looping box on the street light/ security light pole of standered size including providing and fixing 4 way connector of 10 Amp rating and single pole MCB 6 Amp rating in the PVC Looping Box . Make syntex
20
25660
1283
SITC of 800 A with 4pole pole, 36 KA breaking capacity,Ics=%Icu 100%, MCCB make L&T to be fixed directly on existing electrical panel this include dismantling of faulty existing fitted MCCB cable etc and after making all good desired modification/fixing/ thimbling etc complete in all respect as per direction of engineer in charge. Make GE Model LM800B or equiv in L&T/havells)
1
93781
93781
Add Labour cess@1% on Item (Sr.No 1 to 48) i.e Rs 19,41,769/-
1
19417
19417.69
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements