National Security Guard Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

National Security Guard - NSG Tender

Works
Eprocure

Opening Date

19 Mar 2021

Closing Date

30 Mar 2021

Tender Amount

Refer Documents 
Notes
Download

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Above 185 sq. mm and upto 400 sq. mm

400

-

239

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm

50

-

31

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 35 sq. mm and upto 95 sq. mm

50

-

47

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 95 sq. mm and upto 185 sq. mm

50

-

64

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 185 sq. mm and upto 400 sq. mm

50

-

112

... More
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 35 sq. mm

10

-

1988

... More
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 95 sq. mm

6

-

2349

... More
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 120 sq. mm

5

-

2478

... More
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 185 sq. mm

4

-

3683

... More
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 300 sq. mm

2

-

5507

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal)

500

-

149

... More
Tracing/locating and pinpointing of cable faults in the existing underground cable with the help of electrical fault location device including cartage of machine to and fro, tracing fault along with the route of the cable etc. as required.

20

-

9000

... More
Excavation/digging of earth/CC/pucca flooring up to depth of cable and around the location of fault traced of the underground cable, cutting of cable, meggering and checking of type of fault including refilling the excavated area complete in all respect as required.

20

-

1499

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 35 sq. mm

10

-

300

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 95 sq. mm

6

-

473

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 120 sq. mm

5

-

489

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 185 sq. mm

4

-

702

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 300 sq. mm

2

-

936

... More
Supplying and fixing of bus bar chamber of appx. Size 300 mm x 300 mm x 175 mm (NS) comprising of 4 strip aluminium bus bar of 100 amps. Capacity etc. complete as required.

5

-

1500

... More
Excavation for cable trenches of depth upto 1.2 m in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres.

50

-

333

... More
SITC of 400A with 50 KA breaking capacity,Ics=%Icu at 415V(kA rms),630 A current rating MCCB make Havells/L&T/ABB to be fixed directly on existing electrical panel this include dismantling of faulty existing fitted MCCB/cable etc and after making all good desired modification/fixing/thimbling etc complete in all respect as per direction of engineer in charge

2

-

45852

... More
SITC of 250 A with 4 pole, 36 KA breaking capacity,Ics=%Icu 100%,at 415V(kA rms),630A current rating MCCB make Havells/L&T/ABB to be fixed directly on existing electrical panel this include dismantling of faulty existing fitted MCCB/cable etc and after making all good desired modification/fixing/thimbling etc complete in all respect as per direction of engineer in charge.

2

-

41638

... More
SITC of 125 A with 3 pole pole, 25 KA breaking capacity,Ics=%Icu 75%, MCCB make Havells/L&T/ABB to be fixed directly on existing electrical panel this include dismantling of faulty existing fitted MCCB/cable etc and after making all good desired modification/fixing/thimbling etc complete in all respect as per direction of engineer in charge.

5

-

8900

... More
SITC of 63A TPN,C series MCB suitable to work on 240V/415V,50Hz,10 KA breaking capacity make Havells/Standard/L&T to be fixed directly on existing electrical panel this include dismantling of faulty existing fitted MCCB/cable etc and after making all good desired modification/fixing/thimbling etc complete in all respect as per direction of engineer in charge.

10

-

3235

... More
SITC of 40 A TPN,C series MCB suitable to work on 240V/415V,50Hz,10 KA breaking capacity make Havells/Standard/L&T to be fixed directly on existing electrical panel this include dismantling of faulty existing fitted MCCB/cable etc and after making all good desired modification/fixing/thimbling etc complete in all respect as per direction of engineer in charge.

6

-

3125



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.