National Physical Laboratory Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
National Physical Laboratory - NPL Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date19 Jan 2024
Closing Date1 Feb 2024
Tender Amount₹ 31,56,928
Costs
EMD
₹ 63,500Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Up-gradation Renovation Of Furnace Lab For Creating Museum Facility At Npl Campus
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CSIR_182427_1Bid Award Id
ViewTender No
04/0249/2022-WSTender Authority
National Physical Laboratory ViewPurchaser Address
-Website
http://https://www.csir.res.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
17
-
-
... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
9
-
-
... More
12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
137
-
-
... More
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below
12
-
-
... More
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
1
-
-
... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
0.1
-
-
... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
111
-
-
... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby red Area of slab over 0.50 sqm
10
-
-
... More
Providing and laying 60mm thick faciory made cement concreteinterlocking paver block of M -30 grade made by block makingmachine with strong vibratory compaction, of approved size, design& shape, laid in required colour and pattern over and including 50mmthick compacted bed of coarse sand, filling the joints with line sandetc. all complete as per the direction of Engineer-in-charge.
105
-
-
... More
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying
-
-
-
... More
15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity 0.043 w/mK.
396
-
-
... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
209
-
-
... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
53
-
-
... More
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/ 250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick
554
-
-
... More
Painting with aluminium paint of approved brand and manufacture to give an even shade. Two or more coats on new work
554
-
-
... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface
585
-
-
... More
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats
683
-
-
... More
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
683
-
-
... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
683
-
-
... More
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
683
-
-
... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work
120
-
-
... More
Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
1
-
-
... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
868
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
2
-
-
... More
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
9
-
-
... More
(B) Electrical Work:
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
-
-
-
... More
Group C
5
-
-
... More
Supply, Installation, testing and commissioning of recessed/surface mounting LED flat panel 2`X2`, 36 watt with high efficient LEDs and glare free opal diffuser equivalent to cat no. VENUSNEO2X2PLR36WLED865ST of Havells make including hanging/fixing arrangement complete with all respect as directed by engineer incharge. Make should be Phillips/Crompton greaves/Wipro /Havells. (The contractor shall provide minimum three year warrantee for LED light fittings from manufacturers. Security deposite on LED light fittings amounts shall be released after satisfactory completion of warrantee period.)
60
-
-
... More
Supply, Installation, testing and commissioning of 8 watt LED bollard light equivalent to cat no. CONEBLS8WLED830PSYMTOPC of Havells make, on ground at park area including fixing arrangement like connection box, base plate, neccessary foundation messonary work, making hole arrangement using PVC pipe for incoming and outogoing cable in foundation etc complete with all respect as directed by engineer incharge. Make should be Phillips/Crompton greaves/Wipro /Havells. (The contractor shall provide minimum three year warrantee for LED bollard light fittings from manufacturers. Security deposite on LED light fittings amounts shall be released after satisfactory completion of warrantee period.)
30
-
-
... More
Supply, Installation, testing and commissioning of 60 watt LED flood light equivalent to cat no. JETAALBAFLOODLIGHT60W of havells make, on the surface of wall including fixing arrangement like fastners, nut bots etc complete with all respect as directed by engineer incharge. Make should be Phillips/Crompton greaves/Wipro /Havells. (The contractor shall provide minimum three year warrantee for LED light fittings from manufacturers. Security deposite on LED light fittings amounts shall be released after satisfactory completion of warrantee period.)
12
-
-
... More
Supply, Installation, testing and commissioning of 45 watt LED street light equivalent to cat no. ENDURAOMNIPLUSSL45WLED757SASYTOPCSENSO of havells make, on the existing street light poles including fixing arrangement like reducer, 3 core wiring from the mcb of the pole if required, nut bots etc complete with all respect as directed by engineer incharge. Make should be Phillips/Crompton greaves/ Wipro/Havells. (The contractor shall provide minimum three year warrantee for LED light fittings from manufacturers. Security deposite on LED light fittings amounts shall be released after satisfactory completion of warrantee period.)
15
-
-
... More
Supply and erection of 04 meter, double arm bracket, mild steel, street light pole, in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required as directed by engineer incharge
6
-
-
... More
Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) or making brackets by cuting and welding the GI pole including bending the pipe to the required shape etc complete as required as directed by engineer incharge: 40 mm dia
18
-
-
... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Fan should be Havells/ crompton greaves/Usha/Orient or equivalent make with mentioned technical parameter.
24
-
-
... More
Providing & fixing M.S. hook in ceiling for ceiling fan. The hook consist of M.S. plate of size 125 mmx 125 mm x 5mm welded with suitable M.S. hook. The plate is to be fixed in garder/MS channel by welding as required directed by engineer incharge
8
-
-
... More
Supplying and fixing extra down rod of 10 cm length G.I. pipe,15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
216
-
-
... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
-
-
-
... More
1 or 2 Module (75mm x 75mm)
2
-
-
... More
4 Module (125 mmx75mm)
2
-
-
... More
8 Module (125 mmx125mm)
14
-
-
... More
12 Module (200 mmx150 mm)
34
-
-
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. All the switches, socket etc. should be modular screw type equavalent to North West Make should be North West/ Crabtree/ schiender/ panasonic vision/Havells or equavalent.
-
-
-
... More
5/6 amp switch
70
-
-
... More
3 pin 5/6 amp socket outlet
16
-
-
... More
15/16 amp switch
98
-
-
... More
6 pin 15/16 amp socket outlet
96
-
-
... More
Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
96
-
-
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. ( All the wires/cables should be multistrand, ISI marked, Fenolex/ KEI/Polycab/ Havells make)
-
-
-
... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
10
-
-
... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
10
-
-
... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
22
-
-
... More
Supply and laying 3 core 2.5 sqmm FRLS PVC insulated copper conductor (flexible) in existing PVC pipe or surface by clipping etc as required (Cables should be multistrand, ISI marked, Havells/Fenolex/ KEI/Polycab/ make)
150
-
-
... More
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts “C” curve DP MCB complete with connections, testing and commissioning etc. as required. (All the MCB's MCCB, MCB DB, should be Legrand/ L&T/ schneider make or equavalent.)
17
-
-
... More
Supplying and fixing metal box of 200 mm X 250 mm X 75 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required:
14
-
-
... More
Supplying and fixing 25 mm steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required:
40
-
-
... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall/making hole in the wall and making good the same in case of recessed conduit as required.
-
-
-
... More
25 mm.
125
-
-
... More
50 mm.
10
-
-
... More
Supplying and fixing 4 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (All the MCB's MCCB, MCB DB, should be Legrand/ L&T/ schneider make or equavalent.):
6
-
-
... More
Supplying and fixing 4 way (4 + 12), Double door, surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) (All the MCB's MCCB, MCB DB, should be Legrand/ L&T/ schneider make or equavalent.):
1
-
-
... More
Providing and fixing 100 A, 16 kA,TP MCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (All the MCB's MCCB, MCB DB, should be Legrand/ L&T/ schneider make only.)
1
-
-
... More
Supplying and fixing of following rating, 240 /415 volts, C series, miniature circuit breaker of following poles in the existing MCB DB/ MCCB in existing cubical panel board including drilling holes in cubical panel making complete with connections, testing and commissioning as required. (All the MCB's MCCB, MCB DB, should be Legrand/ L&T/ schneider make only.)
-
-
-
... More
5 to 32 amp. SP MCB
16
-
-
... More
63 amp. TPN MCB
2
-
-
... More
Supply of 4 x 16 Sq. Mm, XLPE insulated, PVC sheathed , aluminum conductor armoured cable of 1.1 KV grade as required. ( Cables should be multistrand, ISI marked, Havells/Fenolex/ KEI/Polycab/ make)
100
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
-
-
-
... More
Upto 35 sq. mm
100
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
-
-
-
... More
4 X 16 sq. mm (28mm)
4
-
-
... More
Supply installation,testing & commissioning of double door, cubical LT panel, out door type, suitable for 415V, 3 phase, 4 wire 50 Hz AC supply system having front surface area 1.30 Sq.mtr (indicative) fabricated in compartmentalized design from CRCA sheet steel of 1.6 mm thick for frame work and 2 mm thick for double door and Roof slanting with projected 1 meter front side and 50 cm all other sides, and cover, 3 mm thick for gland plates inclusive cleaning and finishing complete with powder coating in approved shade, having 600 Amp. capacity 4 pole copper busbar with equal size of high conductivity, DMC/ SMC bus bar supports, with short circuit with stand capacity of 31 MVA for 1 sec.,bottom base channel of MS section not less than 50 mm x 50 mm x 6 mm thick with 4 lag and appx 0.5 meter long. The connection from main busbar to switch gear and from switch gear to output terminal should be solid connection by required size of copper busbar. inclusive supply and fixing followings switchgears:
-
-
-
... More
1) 4 pole 400 Amp, 50 kA MCCB ---01 nos
2) 4 pole 125 Amp.36k A,MCCB --07 nos
3) 4 pole 600 Amp. Copper busbar of equal size housed in chamber ----------------------------------01 set
4) Analog 96 mm square flush pattern digital type Voltmeter (0-500V) -------------------- 01 set
5) Analog 96 mm square flush pattern digital type Ammeter (0-500A) ----------------------01 set
6) 3 nos. Phase indication LED lamp with 2 Amp. back up HRC fuse --------------------------01 set
1
-
-
... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
2
-
-
... More
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
10
-
-
... More
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
4
-
-
... More
Dismentalling and disconnection of old DB's DB's / small panels, switch board, tube, light fitting, fan, cable, wiring, conduit, etc as required as following.
-
-
-
... More
TL fitting, switch socket board, Db'/small panels etc.
100
-
-
... More
Wiring , cable and Conduit etc.
200
-
-