If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
National Physical Laboratory - NPL Tender
Civil And Construction
Eprocure
Opening Date22 Jun 2018
Closing Date2 Jul 2018
Tender Amount₹ 44,49,993
Costs
EMD
₹ 89,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Creation of testing and callibration facility at NPL. Civl and electrical
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_CSIR_12070_1Bid Award Id
ViewTender No
04/0141/2018 WS RETender Authority
National Physical Laboratory ViewPurchaser Address
-Website
http://https://www.csir.res.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Creation of testing and callibration facility for LED and LED lighting at NPL. Civil and electrical.
BOQ for the work Creation of testing and callibration facility for LED and LED lighting at NPL
Complete tender document for the work Creation of testing and callibration facility for LED and LED based lighting at NPL
BOQ Items
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
-
-
-
Of area 3 sq. metres and below
18
-
-
Of area beyond 3 sq. metres
8
-
-
Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm (Double charged tiles)
670
-
-
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm (Double charged tiles)
54
-
-
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm
724
-
-
Extra for using glazed vitrified tiles in matt finish in place of double charged vitrified tiles.
724
-
-
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.:- Granite of any colour and shade, Area of slab over 0.50 sqm
7
-
-
Extra for making edge of 18mm thick granite to 36mm by pasting 70mm wide granite strip with suitable epoxy including cost of granite.
16
-
-
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
7
-
-
15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand)
158
-
-
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
137
-
-
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. With cement mortar 1:4 (1 cement : 4 fine sand)
50
-
-
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
758
-
-
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
758
-
-
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
825
-
-
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats
825
-
-
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
816
-
-
Providing and Fixing 15 mm thick densified tegular edged (15mm thick on edges & 8mm thick in body) eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm
-
-
-
interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening“for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/ opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity 0.043 w/mK. (Ceiling is to be done at about 5-7 mtr height).
579
-
-
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
900
-
-
Extra for using builtup tubular sections (round, square or rectangular hollow sections) in place builtup sections.
900
-
-
Providing and fixing of external wall system on Light gauge steel frame work with . Outer face having 6mm thick heavy duty fiber cement board fixed on 9mm thick heavy duty fiber cement board confirming to IS 14862:2000, category IV type A (High pressure steam cured) as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approved make. A grove of 2 mm to 3mm shall be maintained and groves shall be sealed with silicon based sealant. The board shall be fixed in a staggered pattern.Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45 mm and internal face 12.5mm thick gypsum plaster board fixed on 8mm thick fiber cement board confirming to IS 14862:2000 of category III type B (High pressure steam cured) as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish.(cost of frame work to be paid for separately).
60
-
-
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
-
-
-
For fixed portion, Powder coated aluminium (minimum thickness of powder coating 50 micron)
1235
-
-
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots (heavy weight S.S. hinges 125x64x2.5mm in case of door shutters & 100x60x2.5mm in case of window shutters) and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminium (minimum thickness of powder coating 50 micron)
109
-
-
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides
139
-
-
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.50 mm thickness
60
-
-
Deduct for using 5 mm thick glass in place of 5.50 mm thick.
60
-
-
Providing and fixing stainless steel tower bolt 250mm, with rod size 10 mm square knob with necessary SS/CP brass screws. (make Harrison/ Hardwyn/ Dorma).
10
-
-
Providing and fixing s.s. pin Cylindrical Dead lock 70mm i/c S.S. Cap for Key & rubber buffers Harrison or equivalent make.
1
-
-
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness
5
-
-
Providing and fixing aluminium extruded door closer of Harrison make RM-2000. Equivalent door closer of Godrej/Hardwyn make may be used after approval of Engineer-in-charge.
5
-
-
Deduct for disposal/taking out of old dismantled scrap of aluminium partition from the location where it has been dismantled.
140
-
-
Deduct for disposal/taking out of old dismantled scrap of mild steel like angle, tee, flat, doors/ windows sections, etc. from the location where it has been dismantled.
557
-
-
Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead: Thickness above 10 mm up to 25 mm
98
-
-
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
8.5
-
-
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
1.8
-
-
Extra for tinted glass in place of plain float glass. 5mm thick.
10
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size).
2
-
-
Providing and fixing ISI marked 18mm MDF BOARD both side liaminated, exterior grade in cabinet boxes, shutters, drawer, table tops etc. including necessaary screw etc. The edge of board is to be sealed with 0.8 mm lamination/PVC edge bending tape or epoxy paint as per requirement. Fittings like hinges, channels, shall be paid extra. Actual board fixed shall be measured for payment.
94
-
-
Providing and fixing ISI marked 8mm thick prelaminated MDF BOARD, both side liaminated, exterior grade in cabinet boxes drawer etc, including necessaary screw etc. Actual with choice laminated on one side & balancing lamination on other side board area fixed shall be measured for payment.
22
-
-
Providing and fixing SS cabinet hinges suitable for 18 mm board E-series Ozone Make including necessary screws. Equivalent make may be used after approval of Engineer in-charge.
80
-
-
Providing and fixing pair of 450 mm standard ball bearing side (telescopic) of ozone make. Equivalent make may be used after approval of Engineer in-charge.
10
-
-
Providing and fixing 150 mm SS decorative handles for cabinet of approved make. Equivalent make may be used after approval of Engineer in-charge. (Harrison/ Dorma or equivalent make)
20
-
-
Providing and fixing 65 mm cupboard lock -Harrison Code-021A. Equivalent make may be used after approval of Engineer in-charge.
10
-
-
Extra for moulding to 36 mm thick granite stone in place of 18mm thick including polishing to edge to give high gloss finish.
16
-
-
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
50
-
-
(B) ELECTRICAL WORK:
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C
120
-
-
Supply, Installation, testing and commissioning of recessed/surface mounting LED flat panel 2`X2`, 36 watt ith high efficient LEDs and glare free opal diffuser equavalent to cat No. HLFPR22-07-36/HLFPS22-07-36 of Halonix make complete with all respect including hanging/fixing arrangement. Make should be Phillips/Crompton greaves/ Halonix/Havells
100
-
-
Supply Installation, testing and commissioning of surface/wall mounted 20 Watt indoor decoative T5 4 feet LED luminaire with opal diffuser. Make should be Phillips/Halonix/Havells/Bajaj. LED fitting will be installed after removing of old existing fitting as required
4
-
-
Supply of 1200 mm sweep, 230 V, AC, 50 Hz, energy efficient five star rating, ceiling fan complete in all respect including blades, capacitor, standard down road upto 30 cm long etc as required. Fan should be ES 50 premium model of Havells/ High speed plus model of crompton greaves or equivalent. All fan should be 5 star rated energy efficient of respective models.
10
-
-
Installation,testing and commissioning of ceiling fan including wiring the down rods of standard length (up to 30 cm) with 1.5sq.mm. FRLS PVC insulated, copper conductor,single core cable as required.
10
-
-
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
10
-
-
Supply and fixing of MS plate 4 mm thick, 100x100 mm with fixing on roof by 4 nos fastners including providing and welding ceiling fan hook on MS plate as required as per site condition.
10
-
-
Supplying and fixing extra down rod of 10 cm length G.I. pipe ,15 mm dia, heavy gauge including painting etc. as required. (Note :More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
40
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
-
-
-
1 or 2 Module (75mmX75mm)
4
-
-
6 Module (200mm X 75mm)
10
-
-
12 Module (200mmX150mm)
40
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
-
-
-
15/16 amp switch
140
-
-
6 pin 15/16 amp socket outlet
140
-
-
Telephone socket outlet
2
-
-
Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
120
-
-
Supplying and drawing 2 pair 0.5 sq mm FR PVC insulated copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
200
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required
-
-
-
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
100
-
-
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
100
-
-
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
50
-
-
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
100
-
-
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
150
-
-
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
100
-
-
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
25
-
-
Supplying and fixing AC box 3 way modular including 20A Single pole 240 volts “C” curve DP MCB complete with all respect, connections, testing and commissioning etc. as required. AC box should be equavalent to anchor 98488 AC box 3-way modular UNO 20A SP, White of anchor make.
5
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator); 4 way, Double door SPN DB
6
-
-
Supplying and fixing DP sheet steel enclosure on surface/ recessalong with 25/32amps 240 volts “C” curve DP MCB complete with connections, testing and commissioning etc. as required.
6
-
-
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
-
-
-
4 way (4 + 12), Double door
2
-
-
8 way (4 + 24), Double door
2
-
-
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A, 16 kA,TPMCCB
4
-
-
Supplying and fixing of following rating, 240 /415 volts, C series, miniature circuit breaker of following poles in the existing MCB DB/ MCCB in existing cubical panel board including drilling holes in cubical panel making complete with connections, testing and commissioning as required.
-
-
-
5 to 32 amp. SP MCB
60
-
-
32 amp. TP MCB
4
-
-
32 amp. TPN MCB
4
-
-
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: 25 mm
70
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall/making hole in the wall and making good the same in case of recessed conduit as required.
-
-
-
20 mm.
100
-
-
50 mm
60
-
-
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. (Cable should be D -Link / Digi link make only) (cable should be marrked by ferrule at both ends)
200
-
-
Supply and fixing one no. wall mounting CAT 6 I/O connection box punch type internet socket with shutter on existing modular box complete in all respect excluding connections as required. (I/O box should be D -Link, Molex,AMP-Netconnect, Panduit make only (connection will be done by department)
5
-
-
Supply of following size of XLPE insulated, PVC sheathed , aluminum conductor armoured cable of 1.1 KV grade as required. 4 x 50 sq.mm.
150
-
-
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
150
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 50 sq. mm (35 mm)
10
-
-
Dismentalling and disconnection of old DB's DB's / small panels, switch board, tube, light fitting, fan, cable, wiring, conduit, etc as required as following.
-
-
-
TL fitting, switch socket board, Db'/small panels etc.
250
-
-
Wiring , cable and Conduit etc.