If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
National Physical Laboratory - NPL Tender
Eprocure
Opening Date21 May 2018
Closing Date28 May 2018
Tender Amount₹ 40,25,005
Costs
EMD
₹ 81,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Renovation of old HRD wing for RASD Division and other rooms at NPL campus
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_CSIR_10701_1Bid Award Id
ViewTender No
04/0142/2018-WSTender Authority
National Physical Laboratory ViewPurchaser Address
-Website
http://https://www.csir.res.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Dismantling/ removing old PVC flooring in sheet or tiles and cleaning the surface by to removing adhesive including stacking of serviceable material and disposal of unserviceable rubbish material to outside NPL campus, including hacking of floor before fixing of tile.
230
-
-
Providing and fixing homogeneous polyvinyl chloride sheet/tile in flooring and skirting in approved pattern on a smooth and damp proof base using rubber based adhesives of approved quality and manufacturer like dunlop S-758, Fevicol SR 998 or equivalent including rolling with light wooden roller weighing about 5 kg. all complete as directed by engineer in charge. in approved colour and shade. 2mm thick.
106
-
-
Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm (Double charge tiles)
610
-
-
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm (Double charge tiles)
53
-
-
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm
663
-
-
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
53
-
-
Providing and Fixing 15 mm thick densified tegular edged (15mm thick on edges & 8mm thick in body) eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm
-
-
-
interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening“for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/ opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity 0.043 w/mK.
317
-
-
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
6
-
-
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.: Cement mortar 1:4 (1 cement :4 coarse sand)
11
-
-
15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand)
42
-
-
12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
42
-
-
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge: With cement mortar 1:4 (1 cement : 4 fine sand)
60
-
-
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
1095
-
-
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
1239
-
-
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
1239
-
-
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. (Final coat to be applied with roller): Two coats
2646
-
-
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work
68
-
-
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
-
-
-
For fixed portion. Powder coated aluminium (minimum thickness of powder coating 50 micron)
516
-
-
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots (heavy weight SS(stainless steel) hinges 125x64x2.5mm in case of door shutter & 100x60x2.5mm in case of window shutter) and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminium (minimum thickness of powder coating 50 micron)
176
-
-
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-in-charge.: Pre-laminated particle board with decorative lamination on both sides
66
-
-
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.50 mm thickness
24
-
-
Deduct for using 5 mm thick glass in place of 5.50 mm thick.
24
-
-
Extra for tinted glass in place of plain float glass. 5mm thick.
24
-
-
Providing and fixing stainless steel tower bolt 250mm, with rod size 10 mm square knob with necessary SS/CP brass screws. (make Harrison/ Hardwyn/ Dorma).
7
-
-
Providing and fixing stainless steel tower bolt 150mm, with rod size 10 mm square knob with necessary SS/CP brass screws. (make Harrison/ Hardwyn/ Dorma).
30
-
-
Providing and fixing chrome finished 250 mm mortice latch & lock complete pack (Rose) of Harrison AURA/ CORAL (code 43562/ 44562) for door shutters with necessary CP brass/SS screws.(equivalent of make Godrej/ Dorma/ Hardwyn may be used).
3
-
-
Providing and fixing aluminium extruded door closer of Harrison make RM-2000. Equivalent door closer of Godrej/Hardwyn make may be used after approval of Engineer-in-charge.
25
-
-
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.:With stainless steel cover plate minimum 1.25 mm thickness. (Suitable for aluminium, wooden, glass doors)
6
-
-
Providing and fixing s.s. pin Cylindrical Dead lock 70mm i/c S.S. Cap for Key & rubber buffers Harrison or equivalent make.
4
-
-
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
12
-
-
French spirit polishing : Two or more coats on new works including a coat of wood filler
333
-
-
Renewing glass panes, with wooden fillets wherever necessary: Float glass panes of thickness 4 mm
14
-
-
Deduct for providing pin headed glass panes instead of ordinary float glass panes weighing 4 mm thick in doors, windows and clerestory windows shutters (Area of opening for glass panes excluding portion inside rebate shall be measured).
14
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size).
1
-
-
Providing and fixing 100mm verticle blind, Vista dust guard or equivalent of make Nova/Mac. Actual fix area shall be mesuared from top of channel to bottom of blinds.
242
-
-
Deduct for disposal/taking out of old dismantled scrap of mild steel like angle, tee, flat, doors/ windows sections, etc. from the location where it has been dismantled.
160
-
-
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately), Including all gaskets to seal the door.
9
-
-
Providing & fixing SS handle set/pair 304 grade, made out of SS pipe of 'D' shape, 22x300mm, including necessary screws (Hardwyn/Dorma/ Hatiz or equivalent)
4
-
-
Providing & fixing glass lock of Hardwyn make, Code no. HEML58B. Equivalent make may be used.
4
-
-
Removal of existing polishing on wood work on locations like wooden wall panelling, wooden doors etc with sand paper/paint remover wherever required.
311
-
-
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.: 40 mm thick with 20 mm nominal size stone aggregate. (Concrete to be done in NPL basement. Nothing extra to be paid for any lead or lift).
400
-
-
Providing and fixing glass strips in joints of terrazo/ cement concrete floors.: 40 mm wide and 4 mm thick
533
-
-
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface
300
-
-
(B) ELECTRICAL WORK:
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C.
120
-
-
Supply, Installation, testing and commissioning of recessed/surface mounting LED flat panel 2`X2`, 36 watt with high efficient LEDs and glare free opal diffuser equavalent to cat No. HLFPR22-07-36/HLFPS22-07-36 of Halonix make complete with all respect including hanging/fixing arrangement. Make should be Phillips/Crompton greaves/ Halonix/Havells
90
-
-
Supply Installation, testing and commissioning of surface/wall mounted 20 Watt indoor decoative T5 4 feet LED luminaire with opal diffuser. Make should be Phillips/Halonix/Havells/Bajaj. LED fitting will be installed after removing of old existing fitting as required
10
-
-
Supply of 1200 mm sweep, 230 V, AC, 50 Hz, energy efficient five star rating, ceiling fan complete in all respect including blades, capacitor, standard down road upto 30 cm long etc as required. Fan should be ES 50 premium model of Havells/ High speed plus model of crompton greaves or equivalent. All fan should be 5 star rated energy efficient of respective models.
30
-
-
Installation,testing and commissioning of ceiling fan including wiring the down rods of standard length ( up to 30 cm) with 1.5sq.mm. FRLS PVC insulated, copper conductor,single core cable as required.
30
-
-
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
30
-
-
Supply and fixing of MS plate 4 mm thick, 100x100 mm with fixing on roof by 4 nos fastners including providing and welding ceiling fan hook on MS plate as required as per site condition.
30
-
-
Supplying and fixing extra down rod of 10 cm length G.I. pipe ,15 mm dia, heavy gauge including painting etc. as required. (Note :More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
120
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
-
-
-
1 or 2 Module (75mmX75mm)
40
-
-
12 Module (200mmX150mm)
120
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
-
-
-
15/16 amp switch
360
-
-
6 pin 15/16 amp socket outlet
360
-
-
Telephone socket outlet
20
-
-
Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
360
-
-
Supplying and drawing 2 pair 0.5 sq mm FR PVC insulated copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
200
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required
-
-
-
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
100
-
-
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
400
-
-
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
50
-
-
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
50
-
-
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
200
-
-
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
50
-
-
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
50
-
-
Supplying and fixing AC box 3 way modular including 20A Single pole 240 volts “C” curve DP MCB complete with all respect, connections, testing and commissioning etc. as required. AC box should be equavalent to anchor 98488 AC box 3-way modular UNO 20A SP, White of anchor make.
30
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator): 4 way, Double door SPN DB
6
-
-
Supplying and fixing DP sheet steel enclosure on surface/ recessalong with 25/32amps 240 volts “C” curve DP MCB complete with connections, testing and commissioning etc. as required.
4
-
-
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator); 4 way (4 + 12), Double door
4
-
-
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.):4 way (4 + 12), Double door
1
-
-
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.: 100 A, 16 kA,TPMCCB
1
-
-
Supplying and fixing of following rating, 240 /415 volts, C series, miniature circuit breaker of following poles in the existing MCB DB/ MCCB in existing cubical panel board including drilling holes in cubical panel making complete with connections, testing and commissioning as required.
-
-
-
5 to 32 amp. SP MCB
60
-
-
6 to 32 amp. SPN MCB
2
-
-
32 amp. TPN MCB
4
-
-
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: 25 mm
100
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall/making hole in the wall and making good the same in case of recessed conduit as required.
-
-
-
25 mm.
100
-
-
50 mm
100
-
-
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. (Cable should be D -Link / Digi link make only) (cable should be marrked by ferrule at both ends)
200
-
-
Supply and fixing one no. CAT 6 punch type internet socket with shutter on existing modular box complete in all respect excluding connections as required. (internet socket should be D -Link, Molex,AMP-Netconnect, Panduit make only (connection will be done by department)
20
-
-
Supply of following size of XLPE insulated, PVC sheathed , aluminum conductor armoured cable of 1.1 KV grade as required. 4 x 16 sq.mm.
100
-
-
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
100
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (28mm)
10
-
-
Dismentalling and disconnection of old DB's DB's / small panels, switch board, tube, light fitting, fan, cable, wiring, conduit, etc as required as following.
-
-
-
TL fitting, switch socket board, Db'/small panels etc.
210
-
-
Wiring , cable and Conduit etc.
350
-
-