National Institute Of Plant Genome Research Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

National Institute Of Plant Genome Research - NIPGR Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date18 Jul 2024
Closing Date14 Aug 2024
Tender Amount₹ 23,70,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply Instalaltion, testing & commissioning of Outdoor Unit

-

-

-

... More
COP of system 3.7 at 100% load & 7.50 at 50% at AHRI condition.The unit shall also have feature to automatically modulate the evaporative temperature between 6 deg C to 10 deg C with respect to load for better comfort and energy efficiency.

-

-

-

... More
Operating range Outdoor Unit shall be capable of maintaining continuous compressor operation under all of the following operating ambient air conditions. a) Operating ambient air conditions - Cooling: -5°C DB to 53°C DB

-

-

-

... More
No derating of cooling capacity at 39 deg C ambient

-

-

-

... More
Inverter PCB cooling: Cooling of the inverter PCB shall be conducted by way of high pressure, sub-cooled liquid refrigerant via heat exchanger attached to rear side of inverter PCB. The full capacity flow of refrigerant shall pass through the heat exchangers to maximize the cooling effect of the PCBs and to aid in the evaporation process and capacity of the outdoor coil during the heating mode. The recovered heat of the PCBs must be used to enhance the overall heating process, other uses or dissipation of heat to ambient shall not be permitted.

-

-

-

... More
10 HP capacity

3

-

-

... More
6 HP capacity

1

-

-

... More
INDOOR UNIT-DUCTABLE TYPE

-

-

-

... More
Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, cordless remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiveing signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.

-

-

-

... More
Mid Static Ductable units (minimum 45 pascal external static pressure)

-

-

-

... More
2.0 TR

1

-

-

... More
High Static Ductable units (minimum 110 pascal external static pressure)

-

-

-

... More
8.0 TR

2

-

-

... More
4.5 TR

1

-

-

... More
Note:- Backdraft dampers shall be provided at the outlet of each 8.0 TR ductable unit.

-

-

-

... More
INDOOR UNIT-HIWALL TYPE

-

-

-

... More
Supply, installation, testing and commissioning of Wall mounted Type Indoor Units each complete with coil, filter, etc. Air conditioners with evaporating unit comprising of cooling coil, blower with motor suitable for operation on 230 volt, 1 phase, 50 Hz, AC supply and as per specifications. The rate shall include cost of cordless Remote controller, Top Plugs, complete length of required size drain pipes and all other accessories required for full-fledged operation of system. Nothing extra shall be paid in this account.

-

-

-

... More
1.6 TR

3

-

-

... More
Supply, Installation, Testing and commissioning of Imported fittings (Ref Net) Y-joints etc.

3

-

-

... More
Supplying, installation, testing and commissioning of Central Remote Controller for integrating and effecient control of Indoor and Outdoor Units from Station Controller room. Rate shall include all required and asssociated accessories for complete functionality of the equipment as per technical specification. The equipment shall have inbulit compatability for integration with BMS susytem through RS485 communication port with MODBUS protocol.

1

-

-

... More
TOTAL SUB WORK 'A'

-

-

-

... More
SUB WORK 'B'- AIR DISTRIBUTION

-

-

-

... More
DUCTING, GRILLS, DIFFUSER AND INSULATION

-

-

-

... More
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.

-

-

-

... More
Thickness 0.63 mm sheet (24G)

50

-

-

... More
Thickness 0.80 mm sheet (22G)

10

-

-

... More
Make: Ductofab/ADS/Zeco

-

-

-

... More
Make for GSS Sheet: TATA/Bhushan/SAIL

-

-

-

... More
Duct Insulation

-

-

-

... More
Supplying , installation, testing & commissioning of external thermal insulation on ducts with Duly laminated aluminum foil of mat finish Closed Cell Nitrile Rubber (class “O”) insulation after applying of suitable adhesive for nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per tender specification

-

-

-

... More
19 mm thick Closed Cell Nitrile rubber insulation with Factory Laminated Aluminium Foil for Supply Air Duct

50

-

-

... More
Makes: Armacell/A Flex/ K Flex

-

-

-

... More
Acoustic Lining

-

-

-

... More
Supply, Installation, Testing and Commissioning of Acoustic lining inside ducts using open cell elastomeric insulation with antimicrobial protection having 140-160 kg/cum density & as per specifications

-

-

-

... More
15mm thick armasound

10

-

-

... More
Makes: Armacell/A Flex/ K Flex

-

-

-

... More
Supply Air Diffuser

-

-

-

... More
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core

1

-

-

... More
Make: Mapro/ADS/System Air / Caryaire

-

-

-

... More
Return Air Diffuser

-

-

-

... More
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core

1

-

-

... More
Make: Mapro/ADS/System Air / Caryaire

-

-

-

... More
TOTAL SUB WORK 'B'

-

-

-

... More
SUB WORK 'C'- PLUMBING

-

-

-

... More
REFRIGERANT PIPING

-

-

-

... More
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :

-

-

-

... More
6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 13 mm thick insulation

10

-

-

... More
9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 13 mm thick insulation

25

-

-

... More
12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 13 mm thick insulation

12

-

-

... More
15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 13 mm thick insulation

5

-

-

... More
19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 13 mm thick insulation

10

-

-

... More
22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 13 mm thick insulation

10

-

-

... More
28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation

10

-

-

... More
NOTE:- (1) The Copper Piping & Piping Circuit should be with Minimum Number of joints, which shall be attained by : (i) Using One End Expanded Tubes (ii) Bending the tubes instead of using elbow joints wherever 90 degree bending is required. (2) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimum. (3) The makes of tube fittings shall be same as that of tubes. (4) The thickness of fittings used shall be same as that of the pipe.

-

-

-

... More
Makes of Copper Pipe: Mandev/Rajco/Maxflow

-

-

-

... More
Makes of XLPE Insulation: Trocellen/CANI/Armacell / K Flex

-

-

-

... More
PVC Drain Piping

-

-

-

... More
Supply, Installation, testing and commissioning of PVC piping complete with fittings, supports accessories in surface/recess as per specifications & site requirments including with duly insulated with 6 mm thick sleeve of nitrle rubber having K value 0.033 W/MK at 10 deg. C mean temp. and minimum density of 25 Kg/Cum. Insulation on drain pipe

-

-

-

... More
25 mm Dia

35

-

-

... More
32 mm dia

5

-

-

... More
Makes: AKG/Supreme/Astral

-

-

-

... More
TOTAL SUB WORK 'C'

-

-

-

... More
SUB WORK 'D'- ELECTRIC WORKS

-

-

-

... More
Weather Proof isolators for Outdoor Units

-

-

-

... More
Supplying, installation testing and commissioning of 415 volt three phase and neutral swith outlets TPN MCCB/MCB iasolator in weather proof IP 65 enclosure. The quantities of isolators is as follows.

-

-

-

... More
40 amps TPN MCB in weather proof enclosure for 1 Nos. 10 HP VRV outdoor units.

3

-

-

... More
32 amps TPN MCB in weather proof enclosure for 1 Nos. 6 HP VRV outdoor units.

1

-

-

... More
Makes: LEGRAND/ABB/ SEIMENS / L & T

-

-

-

... More
Power Cabling

-

-

-

... More
Supply and laying of the following 1100 volt grade armoured XLPE insulated and PVC sheathed aluminium conductor cable in trench / cable tray /clamped to wall with suitable clamps saddles & fixing bolts/including testing & commissioning complete as required. The costs shall include crimping tinned heavy duty alluminium lugs, compression glands requisite materials for all cables and to provide with 1D gap & shall be properly clamped with cable clamps & ties. Identification tags shall be provided for all cables including cable end termination.

-

-

-

... More
4 core 10 Sq mm

10

-

-

... More
4 core 6 Sq mm

10

-

-

... More
Makes: POLYCAB / FINOLEX / KEI

-

-

-

... More
CONTROL CABLING

-

-

-

... More
Supply, laying, testing and commissioning of PVC insulated and PVC sheathed, unarmoured, Copper Conductor of 1.1 KV grade on existing cable trays as per Standard specification including end termination as required.

-

-

-

... More
2C x 1.0 Sq mm

20

-

-

... More
3C x 2.5 Sq mm

30

-

-

... More
Makes: POLYCAB / FINOLEX / KEI

-

-

-

... More
Electrical Cable Tray

-

-

-

... More
Supply and installation of following size of perforated painted with powder coating G.I. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including bolts & nuts, painting suspenders etc as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

10

-

-

... More
250 mm width X 50 mm depth X 1.6 mm thickness

40

-

-

... More
Earthing

-

-

-

... More
Makes: RALBO/ MEM / SLOTCO

-

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

80

-

-

... More
TOTAL SUB WORK 'D'

-

-

-

... More
SUB WORK 'A'-MACHINERY

-

-

-

... More
SUB WORK 'B'- AIR DISTRIBUTION

-

-

-

... More
SUB WORK 'C'- PLUMBING

-

-

-

... More
SUB WORK 'D'- ELECTRIC WORKS

-

-

-

... More
Consultant Engineer

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.