National Institute Of Immunology Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

National Institute Of Immunology - NII Tender

Goods
GEM
Opening Date13 Mar 2024
Closing Date25 Mar 2024
Tender Amount₹ 20,48,425.72 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
As per ATC Copper pipe1 , 6.35 mm dia (OD) (Softdrawn) with tube thickness 0.8 mm with 19 mm thick insulation

50

-

-

... More
As per ATC Copper pipe2 , 9.5 mm dia (OD) (Softdrawn) with tube thickness 0 .8 mm with 19 mm thick insulation

50

-

-

... More
As per ATC Copper pipe3 , 12.7 mm dia (OD) (Softdrawn) with tube thickness 0 .8 mm with 19 mm thick insulation

50

-

-

... More
As per ATC Copper pipe4 , 15.86 mm dia (OD) (Softdrawn) with tube thickness 1 mm with 19 mm thick insulation

50

-

-

... More
As per ATC Copper pipe5 , 19 mm dia (OD) (Harddrawn) with tube thickness 1 mm with 19 mm thick insulation

20

-

-

... More
As per ATC Copper pipe6 , 22.2 mm dia (OD) (Harddrawn) with tube thickness 1 mm with 19 mm thick insulation

15

-

-

... More
As per ATC Copper pipe7 , 28.58 mm dia (OD) (Harddrawn) with tube thickness 1 mm with 19 mm thick insulation

25

-

-

... More
As per ATC Copper pipe8 , 34.9 mm dia (OD) (Harddrawn) with tube thickness 1.2 mm with 19 mm thick insulation

25

-

-

... More
As per ATC UPVC 25mm , Supply Installation Testing and Commissioning Providing and fixing rigid UPVC piping complete with fittings, supports as per specifications and duly insulated with 9 mm thick closed cell nitrile rubber insulation 25 mm

30

-

-

... More
As per ATC UPVC 32mm , Supply Installation Testing and Commissioning Providing and fixing rigid UPVC piping complete with fittings, supports as per specifications and duly insulated with 9 mm thick closed cell nitrile rubber insulation 32 mm

30

-

-

... More
Joints , Supply Installation Testing and Commissioning of Refnets/ Y-Joints/ T-Joints as per OEM recommendation and upto the satisfaction of engineer in-charge at site.

5

-

-

... More
Transmission wire , Supply Installation Testing and Commissioning of control cum transmission wiring of copper in suitable PVC conduits between indoor and outdoor units size as per OEM recommendation (should be shielded cable in PVC conduits)

200

-

-

... More
8SWG , Providing and fixing 8 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/cable as required.

100

-

-

... More
As per ATC Power cable 10sq.mm , Supply of Power Cable of following sizes XLPE insulated cable to VRV / VRF ODU and IDUs from electrical panel. The cost shall included all necessary supports, clamps etc as necessary as required 4 C x 10 Sqmm (Copper Armoured)

50

-

-

... More
As per ATC Power cable 2.5sq.mm , Supply of Power Cable of following sizes XLPE insulated cable to VRV / VRF ODU and IDUs from electrical panel. The cost shall included all necessary supports, clamps etc as necessary as required 3 C x 2.5 Sqmm (Copper Flexible for IDUs)

60

-

-

... More
As per ATC Power cable 10sq.mm 35sq.mm , Providing, Laying and fixing on surface Power Cable of following sizes XLPE insulated cable to VRV / VRF ODU and IDUs from electrical panel. The cost shall included all necessary supports, clamps etc as necessary as required Up to 35 sq.mm

110

-

-

... More
DB , Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 100 A tinned copper bus bar, common neutral link, earth bar, din bar MCBs as required . INCOMING 25 A 4P MCB - 1 Set, OUTGOING 2A / 6A DP MCB - 6 Set

1

-

-

... More
150mm , Supplying and Installing following size of perforated Hot Dipped galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders i/c G.I. bolts & nuts, etc as reqd. 150 mm width X 50 mm depth X 1.6 mm thickness

65

-

-

... More
375mm , Supplying and Installing following size of perforated Hot Dipped galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders i/c G.I. bolts & nuts, etc as reqd. 375 mm width x 50 mm depthx 2 mm thickness.

65

-

-

... More
Isolator , Providing and fixing of weather proof Isolator near the ODU. 4P 40/63 A TPN with weather proof box.

1

-

-

... More
Isolator 2P , Providing and fixing of isolator near the Indoor Unit. 2P, 2/6A.

6

-

-

... More
CAMC1 , Comprehensive Annual Maintenance of the complete VRV/ VRF System including each and every items/parts, compressor, refrigerant, cable, wire, copper pipe, MCB etc originally installed with the system shall be covered under this contract as per the scope of work and conditions as per the ATC. Year 1 - After DLP

1

-

-

... More
CAMC2 , Comprehensive Annual Maintenance of the complete VRV/ VRF System including each and every items/parts, compressor, refrigerant, cable, wire, copper pipe, MCB etc originally installed with the system shall be covered under this contract as per the scope of work and conditions as per the ATC. Year 2

1

-

-

... More
CAMC3 , Comprehensive Annual Maintenance of the complete VRV/ VRF System including each and every items/parts, compressor, refrigerant, cable, wire, copper pipe, MCB etc originally installed with the system shall be covered under this contract as per the scope of work and conditions as per the ATC. Year 3

1

-

-

... More
CAMC4 , Comprehensive Annual Maintenance of the complete VRV/ VRF System including each and every items/parts, compressor, refrigerant, cable, wire, copper pipe, MCB etc originally installed with the system shall be covered under this contract as per the scope of work and conditions as per the ATC. Year 4

1

-

-

... More
CAMC5 , Comprehensive Annual Maintenance of the complete VRV/ VRF System including each and every items/parts, compressor, refrigerant, cable, wire, copper pipe, MCB etc originally installed with the system shall be covered under this contract as per the scope of work and conditions as per the ATC. Year 5

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.