Municipal Council Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 10,27,351Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Replacement Of 300 Mm Dia Ci Line With D.i. Pipe From Bharti Nagar Water Boosting Station To Delhi High Court Including Kaka Nagar Under Sub Division-iii(w/s)
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_NDMC_263813_1Bid Award Id
ViewTender No
13/EE(W/S)/2024-25Tender Authority
Municipal Council ViewPurchaser Address
-Website
http://https://www.ndmc.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Demolishing cement concrete manually/by mechanically means including disposal of material within 50 metre lead.as per direction of Engineer-in-charge.1:4:8 or leaner mix.
319
1239
395432
... More
Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : Water Bound Macadaum
282
690
194687
... More
Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. Bituminous road
362
1150
416528
... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
5728
286
1643077
... More
Providing and laying S&S centrifugal cast (spun) ductile iron pipes confirming to IS: 8329. 150 mm dia Ductile Iron Class K-9 pipes
4990
1625
8109000
... More
Providing and laying S&S centrifugal cast (spun) ductile iron pipes confirming to IS: 8329. 300 mm dia Ductile Iron Class K-9 pipes
3411
3882
13243890
... More
Providing and fixing VAG/AVK/TALIS/IVC/DOROT or equivalent PN-16 double flanged ductile iron resilient seated sluice /Gate valve (with stem cap), electro statically applied epoxy coating with stainless steel stem, DI wedge fully encapsulated with EPDM rubber complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately.) 150 mm dia metre.
30
24672
740182
... More
Providing and fixing VAG/AVK/TALIS/IVC/DOROT or equivalent PN-16 double flanged ductile iron resilient seated sluice /Gate valve (with stem cap), electro statically applied epoxy coating with stainless steel stem, DI wedge fully encapsulated with EPDM rubber complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately.) 300 mm dia metre.
8
77198
617586
... More
Providing and fixing VAG/AVK/TALIS/IVC/DOROT or equivalent PN-16 double orifice ductile iron resilient seated Air valve (with stem cap), electro statically applied epoxy coating with stainless steel stem, DI wedge fully encapsulated with EPDM rubber complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately.) 100 mm dia metre.
5
50581
252909
... More
Providing and fixing VAG/AVK/TALIS/IVC/DOROT or equivalent PN-16 ductile iron resilient seated sluice Non Return Valve (with stem cap), electro statically applied epoxy coating with stainless steel stem, DI wedge fully encapsulated with EPDM rubber complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately.) 150 mm Diameter
3
39604
118814
... More
Providing and fixing VAG/AVK/TALIS/IVC/DOROT or equivalent PN-16 ductile iron resilient seated sluice Non Return Valve (with stem cap), electro statically applied epoxy coating with stainless steel stem, DI wedge fully encapsulated with EPDM rubber complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately.) 300 mm Diameter.
2
149857
299714
... More
Providing and laying D.I. special of class K-12 suitable for mechanical jointing as per IS: 9523. upto 600 mm dia.
23
18025
414589
... More
Providing and laying D.I specials for class K-12 suitable for push on jointing as per IS: 9523.upto 600 mm dia
92.5
17155
1586921
... More
Providing and laying S&S C.I. standard special such as tees, bends, collars, tapers, caps(Heavy class). Upto 300 mm dia
5
7509
37547
... More
Providing lead caulked joints to spun iron or C.I. pipe and specials including testing of joints but excluding the cost of pig lead. 150 mm dia metre pipe
10
615
6158
... More
Providing lead caulked joints to spun iron or C.I. pipe and specials including testing of joints but excluding the cost of pig lead. 300 mm dia metre pipe
10
1230
12307
... More
supplying pig lead at site of work
0.94
28116
26429
... More
Providing Push–on-joints to centrifugally (Spun) cast iron pipes or ductile iron pipes including testing of joints and including the cost of rubber gasket. 150 mm dia
1433
156
223620
... More
Providing Push–on-joints to centrifugally (Spun) cast iron pipes or ductile iron pipes including testing of joints and including the cost of rubber gasket. 300 mm dia pipe
875
357
312900
... More
Excavating pit for fixing sluice valve and or non-return valve and /or C.I. specials in the existing c.I./D.I. water line including cutting of C.I/D.I pipe line taking out the cut pipe pieces pumping of bailing out water caused by cutting of line and refilling the pit etc. complete. For C.I. line above 80mm dia and upto 150 mm dia.
38
7033
267271
... More
Excavating pit for fixing sluice valve and or non-return valve and /or C.I. specials in the existing c.I./D.I. water line including cutting of C.I/D.I pipe line taking out the cut pipe pieces pumping of bailing out water caused by cutting of line and refilling the pit etc. complete. For C.I. line above 150mm dia and upto 300 mm dia.
10
10631
106319
... More
Conducting SUE Survey in a corridor of 4-6 meter width to detect buried utilities like pipes, cables etc. in such corridor. Making of the detected utilities on thhe map of corridor with information of locations and depths to the top of various utilities detected. Onsite detection to be conducted using minimum tools of Electronic Pipe Locator (EPL) and Ground Penetrating Radar (GPR). GPR work to be conducted using 500 MHz and 300MHz antenna for best possible resolution and penetration. The specifications are SUE survey should be in accordance with Code of Practice for Subsurface Utility Engineering Suiting Indian Conditions guidelines & Specifications for Detection, Verification & Depiction of Existing Subsurface Utility Data. Along the road 6 meter vide
8401
54
459871
... More
Conducting SUE Survey in a corridor of 4-6 meter width to detect buried utilities like pipes, cables etc. in such corridor. Making of the detected utilities on thhe map of corridor with information of locations and depths to the top of various utilities detected. Onsite detection to be conducted using minimum tools of Electronic Pipe Locator (EPL) and Ground Penetrating Radar (GPR). GPR work to be conducted using 500 MHz and 300MHz antenna for best possible resolution and penetration. The specifications are SUE survey should be in accordance with Code of Practice for Subsurface Utility Engineering Suiting Indian Conditions guidelines & Specifications for Detection, Verification & Depiction of Existing Subsurface Utility Data. Roads crossing without dividers upto 30m width
22
50227
1105008
... More
Conducting SUE Survey in a corridor of 4-6 meter width to detect buried utilities like pipes, cables etc. in such corridor. Making of the detected utilities on thhe map of corridor with information of locations and depths to the top of various utilities detected. Onsite detection to be conducted using minimum tools of Electronic Pipe Locator (EPL) and Ground Penetrating Radar (GPR). GPR work to be conducted using 500 MHz and 300MHz antenna for best possible resolution and penetration. The specifications are SUE survey should be in accordance with Code of Practice for Subsurface Utility Engineering Suiting Indian Conditions guidelines & Specifications for Detection, Verification & Depiction of Existing Subsurface Utility Data. Roads crossing with dividers upto 50m width
2
100455
200910
... More
Installation of Steel product pipe by HDD method including preparing and setting up the plant and equipment, preparing new pipe-work material, installing new pipe-work and commissioning system or making the system ready for commissioning by HDD operation including, all elated civil and mechanical works like excavation, shoring/strutting, etc. drilling, stringing, reaming, and pulling back the new pipe-work on the designed bore path alignment, proper disposal of drilling fluid and restoration of the site after completion all inclusive as per IndSTT: 101-2018: Code of Practice for Horizontal Directional Drilling Technique suiting Indian Conditions. For Installation Lengths upto 100m, Steel Pipes above 200 mm & upto 300, In Mixed Soil
230
8316
1912802
... More
Installation of Steel product pipe by HDD method including preparing and setting up the plant and equipment, preparing new pipe-work material, installing new pipe-work and commissioning system or making the system ready for commissioning by HDD operation including, all elated civil and mechanical works like excavation, shoring/strutting, etc. drilling, stringing, reaming, and pulling back the new pipe-work on the designed bore path alignment, proper disposal of drilling fluid and restoration of the site after completion all inclusive as per IndSTT: 101-2018: Code of Practice for Horizontal Directional Drilling Technique suiting Indian Conditions. For Installation Lengths from 100m and upto 200m, Steel Pipes above 200 mm & upto 300 mm dia. In Mixed Soil
290
15014
4354257
... More
Supplying M.S. Carrier Pipe of required thickness made up of M.S. Plate Heavy (C class) as per IS : 1239 PART-I (2004) , within the entire satisfaction of Engineer-in-charge including loading & unloading and cartage.150 mm dia
160
3114
498349
... More
Providing Mild Steel Pipes fabricated /manufactured out of MS coil of steel grade Fe410 as per IS 3589:2001;internally lined with cement mortar lining and external / Outside epoxy coating; minimum thickness of M.S.Coil as specified; complete in all respect; with upto date amendments irrelevant IS codes and as directed by Engineer-in-charge. 300 mm internal Diameter
360
11636
4189003
... More
Hiring of DG set 62.00 KVA, welding machine gas cutter, oxygen & LPG gas cylinder, welding electrodes, welder etc. complete including diesel & operators as per direction of Engineer-in-charge.
25
6957
173932
... More
Pumping out water/Sewerage water by deploing 5 H.P. to 7.5 H.P. diesel pump set including disposal of sewerage water for (any lift) in to municipal drain (only running time of pump in Hours and minutes will be measured. and nothing extra shall be paid)
100
1477
147755
... More
Constructing brick masonry chamber 120x120x100cm (inside) size with 75 class designation FPS bricks in cement mortar 1:6( 1 cement : 6 coarse sand derived from natural sources ) for sluice valve / reflux valve 150mm thick RCC top slab with 560mm dia opening 1:2:4 mix (1cement : 2 coarse sand including manufactured sand derived from Recycledconcrete aggregate (RCA) upto 20% : 4 graded stone aggregate 20mm nominal size of Recycled concrete aggregate (RCA) upto 20%) reinforced with 26.71 Kg. cold twisted steel bars necessary excavation and refilling and laying 10cm thick foundation concrete 1:5:10 ( 1 cement : 5 Manufactured sand derived from Recycled concrete aggregate (RCA) :10 graded stone aggregate 40 mm nominal size Recycled aggregate (RA)) and inside plastering 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand derived from natural sources) finished with a floating coat of neat cement complete as per standard design.
10
21210
212101
... More
Constructing brick masonry chamber 90x90x100cm (inside) size with 75 class designation FPS bricks in cement mortar 1:6( 1 cement : 6 coarse sand derived from natural sources ) for sluice valve / reflux valve 150mm thick RCC top slab with 560mm dia opening 1:2:4 mix (1cement : 2 coarse sand including manufactured sand derived from Recycledconcrete aggregate (RCA) upto 20% : 4 graded stone aggregate 20mm nominal size of Recycled concrete aggregate (RCA) upto 20%) reinforced with 16.30 Kg. cold twisted steel bars necessary excavation and refilling and laying 10cm thick foundation concrete 1:5:10 ( 1 cement : 5 Manufactured sand derived from Recycled concrete aggregate (RCA) :10 graded stone aggregate 40 mm nominal size Recycled aggregate (RA)) and inside plastering 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand derived from natural sources) finished with a floating coat of neat cement complete as per standard design.
38
15260
579907
... More
Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. EHD-35 Circular shape 560 mm internal dia
48
1882
90346
... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
5106
253
1296669
... More
Providing and fixing sant / leader or equivalent ISI marked gun metal ferrule with provision ofNRV including boring and tapping the mainetc. complete : 15 mm dia nominal bore
400
1231
492684
... More
Providing and fixing Polyethelene-Aluminium- Polyethylene (PE-AL-PE) Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with trenching, refilling and testing of joints complete as per direction of the engineer in charge. 1620 (20mm OD Pipe)
6000
292
1755900
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 10 graded stone aggregate 40 mm nominal size Recycled Aggregate (RA)
236.24
4440
1048965
... More
Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
1477
951
1404627
... More
Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost).
1477
362
535117
... More
Disposal of building rubbish / malba/ similar unserviceable, dismantled or waster materilas by mechanical means, including loading, transporting annd unloading the same at any C&D waster management site within 25 Kms. Lead i.e. Shastri park /Burari / Mundka including weighing at plant etc. complete as per direction of Engineer in charge. Weighing and unloading at the plant shall be as per procedure / rules of the plant management. The rates are inclusive of all operations, labours, leads and lifts from site of work to the C& D waste plant. The processing fee of C&D managment at prescribed rates will be deposited by the agency and the same shall be reimbursed by the department on production of only original cash receipt.
681
435
296235
... More
Carriage of Earth by Mechanical means, including loading, Transporting, unloading to approved Municipal Dumping Ground as approved by Engineer-in-Charge upto 01 Kilometer lead
329
143
47142
... More
Extra for every additional lead of 1.00 Km and part thereof beyond intial lead of 1 Kilometre and upto 25.00 Kilometre.
7899
17
134678
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements