Municipal Corporation Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Municipal Corporation Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date31 Jul 2024
Closing Date7 Aug 2024
Tender Amount₹ 44,11,459 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
4.1.3:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thickness

5

3445

689.01

... More
4.1.1:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness

12

6518

543.23

... More
4.3.1:Supplying and installing following size of perforated pre-painted M.S. cable trays reducers with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness

5

5013

1002.78

... More
4.3.3:Supplying and installing following size of perforated pre-painted M.S. cable trays reducers with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.200 mm width X 50 mm depth X 1.6 mm thickness

7

10122

1446.09

... More
9.1.23:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

4

1873

468.45

... More
9.1.24:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)

4

2351

587.87

... More
5.3:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.

6

37535

6255.95

... More
5.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

35

5023

143.54

... More
1.1.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

8

14584

1823.01

... More
1.7.2:Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2X2.5 sq.mm+1X2.5 sq.mm earth wire

20

7388

369.41

... More
1.7.3:Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2x4 sq.mm + 1x4 sq.mm earth wire

34

14566

428.42

... More
1.22.3:Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.150 mm X 75 mm X 60 mm deep

2

431

215.99

... More
1.22.5:Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.180 mm X 100 mm X 60 mm deep

2

489

244.87

... More
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door

1

2573

2573

... More
2.10.1:Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

6

1535

255.9

... More
2.10.3:Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole

1

655

655.96

... More
19.1:Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.

2

5459

2729.61

... More
1.50.1:Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep

2

899

449.98

... More
7.7.1:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

20

1090

54.52

... More
7.7.2:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

60

7801

130.03

... More
DSR Civil

-

-

-

... More
4.1.4:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources)

4

26720

6680.22

... More
Approved rates electrical

-

-

-

... More
122.1.3:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm

20

2310

115.52

... More
122.1.19:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-3.5C*70 sqmm

50

23845

476.91

... More
122.1.20:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-3.5C*95 sqmm

10

6002

600.23

... More
122.1.47:Supply of 250 mm (10 inch) sweep 1250 rpm exhaust fan Fresh Air Type complete with shutter blades etc. as required.

2

3909

1954.8

... More
122.2.2: P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd.

4

2938

734.71

... More
122.2.4:SITC of Pillar box size 900 mm x 450mm x 250mm suitable for mounting incomer of 250 A MCCB/Main switch 4 Pole and energy meter 3 phase complete with eluotropic grade Aluminium bus bar of size 25mm x 19 mm mounted on galvanized M. S. body power quoted pilferage proof SMC door duly welded with S.S. with rain cover size 40mm x 40mm x 5mm x 600mm height in cutting 300 mm height below ground and covered with shode proof SMC sheet of 3 mm as required.

2

30386

15193.23

... More
122.2.29:SITC of 100W LED Flood Light luminiare fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =100 watt +/- 5% (b) Luminaire Efficacy=100 Lm/w (c) Power Factor=0.95 (d) Protection Class- IP-66

4

28500

7125.22

... More
122.2.39:S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt =95 (c)Power Factor =0.95

4

1859

464.89

... More
OD30305/2023-2024:Supply of 16 sq mm ISI marked FRLS PVC insulated, single core copper conductor cable

19

4807

253

... More
Approved rates E&M

-

-

-

... More
OD30306/2023-2024:Supply installation testing and commissioning of Electrical Horizontal centrifugal pump set with non-clog / mf impeller to handle storm/mixed/sewage water with having min. discharge of 800 M³/ Hour at head min 7 mtr, RPM 750 having suction and delivery size 350 mm or 300 mm dia, mounted on a common base frame coupled with min 40 HP or suitable rating(IE-2) three phase , TEFC AC , 415 volts , 50 HZ supply electrical motor energy efficient complete as required.Mounted on a common base frame as Casing CI , Impeller CI,Shaft & sleeve (SS) 40 C 8 complete with coupling guard and foundation bolts etc. as reqd.

2

1172551

586275.99

... More
OD30307/2023-2024:P & F/Replacement of M.S Black pipe (9.5 mm thickness) Conforming to IS:3589 with required nut bolts and packing sheet etc complete as reqd of following dia 400 mm ,9.5 mm thickness

14

354662

25333.01

... More
OD30308/2023-2024:P & F/Replacement of M.S Black pipe (9.5 mm thickness) Conforming to IS:3589 with required nut bolts and packing sheet etc complete as reqd of following dia 350 mm ,9.5 mm thickness

10

132829

13282.99

... More
OD30309/2023-2024:P & F/Replacement of M.S Black pipe (9.5 mm thickness) Conforming to IS:3589 with required nut bolts and packing sheet etc complete as reqd of following dia 300 mm ,9.5 mm thickness

4

48280

12070

... More
OD30310/2023-2024:Providing & Fixing of M.S Flange with required nut bolts and packing sheet etc complete as required of following dia. 400 mm ( 25 mm thickness)

17

75752

4456

... More
OD30311/2023-2024:Providing & Fixing of M.S Flange with required nut bolts and packing sheet etc complete as required of following dia. 350 mm ( 25 mm thickness)

10

36770

3677

... More
OD30312/2023-2024:Providing & Fixing of M.S Flange with required nut bolts and packing sheet etc complete as required of following dia. 300 mm ( 25 mm thickness)

9

27288

3032

... More
OD30313/2023-2024:Providing & Fixing of M.S Blind Flange with required nut bolts and packing sheet etc complete as required of following dia. 400 mm ( 25 mm thickness)

1

6940

6940

... More
OD30314/2023-2024:Providing & Fixing of M.S Bend with required nut bolts and packing sheet etc complete as required of following dia. 400 mm(10 mm thick),length 0.75 m

4

23599

5899.99

... More
OD30315/2023-2024:Providing & Fixing of M.S Bend with required nut bolts and packing sheet etc complete as required of following dia. 350mm(8 mm thick),length 0.75 m

2

9600

4800

... More
OD30316/2023-2024:Providing & Fixing of M.S Bend with required nut bolts and packing sheet etc complete as required of following dia. 300 mm(08 mm thick),length 0.75 m

2

7730

3865

... More
OD30317/2023-2024:Replacement of swing type Non Return Valve of CI Body with Door, bronze to Rubber rings confirming to IS 5312(Part 1 & 2), PN 1.6 complete as required NRV 350 MM

2

355520

177760

... More
OD30318/2023-2024:Replacement of swing type Non Return Valve of CI Body with Door, bronze to Rubber rings confirming to IS 5312(Part 1 & 2), PN 1.6 complete as required NRV 150 MM

1

32317

32317

... More
OD30319/2023-2024:Replacement of Non Rising Spindle Sluice Valve of CI Body with Wedge, Bronze ring confirming to IS 14846 & SS IS:6603 (ISI Marked), PN 1.6 complete as required: SV 350 MM

2

465280

232640

... More
OD30320/2023-2024:Rubber Sheet 10 mm thick

100

7300

73

... More
OD30321/2023-2024:Mounting pad(AVM)

18

35928

1996

... More
OD30323/2023-2024:Providing & Fixing of MS Bar Screen made out of MS channel size 4" x 2" (100 mm x 50 mm) and center covered with MS Flat size 80 x 8 mm duly welded with center to center distance 40 mm and back side supporting channel (100 x 50 mm)duly welded .Work also includes complete bar screen fixing in the drain with the help of heavy crane and complete bar screen duly painted with enamel paint. Bar screen duly fixed in side wall using mortar , tools and tackles. (sq feet)

28

67536

2412

... More
OD30324/2023-2024:S/I/T/C of fully automatic Auto Transformer Starter will be made out / fabricated with 2 mm thick, MS sheet steel ,dust & vermin proof, darn & drip-proof , front operated , self supported, free standing type constructions and will be duly spray painted Sythetic Enamel of light grey shade 631 of IS:5 and accomodate all switch gear items required to meet the technical requirements of ATS 50 HP & Adequate rating Oil immersed Auto Transformer having Copper winding , class 'E' insulation with taping 50%,65%&80%(01 No.)Adequate rating power contactors , Overload relay, Single Phase preventer relay with under voltage & over voltage or as suitable(01 No), Flush mounting type ammeter 96 sqmm with selector switch suitable CT connection (01 No), Voltmeter 96 sqmm with selector switch (01 No), Indicating lamp for ON,OFF,TRIP(03 Nos),Indicating lamp for R,Y,B (03 Nos) without transformer's oil as follows: (1) Switch fuse unit 125 A TPN with handle FN 125 A-1 No.(2) HRC fuse 125 A-3 Nos (3) Star contactor coil voltage 240AC with 2 No +2NC AUX. contacts Block MNX 50- 1No.(4)TAP contactor coil voltage 240AC with 2 No +2NC AUX. contacts Block MNX 50- 1No.(5)Line contactor coil voltage 240AC with 2 No +2NC AUX. contacts Block MNX 50- 1No.(6) Over load relay range -A CT operated 45-75 A MN5-01 No(7) Current Transformer 15 VA , CL. 1 for Metering 100//5A-3 No.(8) Push button start/stop element 22.5 mm dia -2 Nos(9) Indicating lamps 230V AC Red LED Type -3 No(10) MCB 6A 1P MCB , 10 KA -1 No.(11) On Delay Timer 0-30 Sec , Coil voltage 240 V , AC 2AODTS-3 Nos(12) Ammeter ,0-100/5a,(100-600A) Sappress Scale 6-Time,96 Sq. mm with Ameter Selector switch 0-100/5A-1 No . (13) Voltmeter 0-500 V ,96 SQMM size with voltage selector S96-1 No.(14) Single Phase preventer relay with under voltage S2VMR2 1 No

2

376527

188263.99

... More
OD828/2024-2025:SITC of Pump- Non clog sewage solid handling - Suc/Del size 150 mm x 150 mm head 15 mtr & discharge 400 m3/hr , Body-CI, Impeller -SS, Shaft- EN-8, Sleeve-SS with coupling, base frame, fuel tank & leads coupled with 38 BHP diesel engine,1500 RPM , Self start, water cooled with radiator complete with 12 V battery as required

1

790698

790698

... More
OD829/2024-2025:SITC of 4 pole 320 Amp oFF load side handle change over switch conforming to IS: 13947 (Part I & III) in sheet steel enclosure i/c connection etc. complete as required.

2

43790

21895



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.