Municipal Corporation Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Municipal Corporation Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date31 Jul 2024
Closing Date7 Aug 2024
Tender Amount₹ 44,11,459
Costs
EMD
₹ 88,602Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MCD_203232_1Bid Award Id
ViewTender No
EE(E)-II/SNZ/MCD/24-25/TC-5/1Tender Authority
Municipal Corporation ViewPurchaser Address
-Website
http://etenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
4.1.3:Supplying and installing following size of perforated pre-painted M.S. cable trays with
perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thickness
5
3445
689.01
4.1.1:Supplying and installing following size of perforated pre-painted M.S. cable trays with
perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness
12
6518
543.23
4.3.1:Supplying and installing following size of perforated pre-painted M.S. cable trays reducers with
perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness
5
5013
1002.78
4.3.3:Supplying and installing following size of perforated pre-painted M.S. cable trays reducers with
perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.200 mm width X 50 mm depth X 1.6 mm thickness
7
10122
1446.09
9.1.23:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
4
1873
468.45
9.1.24:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)
4
2351
587.87
5.3:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
6
37535
6255.95
5.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
35
5023
143.54
1.1.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
8
14584
1823.01
1.7.2:Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2X2.5 sq.mm+1X2.5 sq.mm earth wire
20
7388
369.41
1.7.3:Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2x4 sq.mm + 1x4 sq.mm earth wire
34
14566
428.42
1.22.3:Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.150 mm X 75 mm X 60 mm deep
2
431
215.99
1.22.5:Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.180 mm X 100 mm X 60 mm deep
2
489
244.87
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
1
2573
2573
2.10.1:Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
6
1535
255.9
2.10.3:Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
1
655
655.96
19.1:Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
2
5459
2729.61
1.50.1:Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep
2
899
449.98
7.7.1:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV
grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
20
1090
54.52
7.7.2:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV
grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
60
7801
130.03
DSR Civil
-
-
-
4.1.4:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources)
4
26720
6680.22
Approved rates electrical
-
-
-
122.1.3:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm
20
2310
115.52
122.1.19:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-3.5C*70 sqmm
50
23845
476.91
122.1.20:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-3.5C*95 sqmm
10
6002
600.23
122.1.47:Supply of 250 mm (10 inch) sweep 1250 rpm exhaust fan Fresh Air Type complete with shutter blades etc. as required.
2
3909
1954.8
122.2.2: P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd.
4
2938
734.71
122.2.4:SITC of Pillar box size 900 mm x 450mm x 250mm suitable for mounting incomer of 250 A MCCB/Main switch 4 Pole and energy meter 3 phase complete with eluotropic grade Aluminium bus bar of size 25mm x 19 mm mounted on galvanized M. S. body power quoted pilferage proof SMC door duly welded with S.S. with rain cover size 40mm x 40mm x 5mm x 600mm height in cutting 300 mm height below ground and covered with shode proof SMC sheet of 3 mm as required.
2
30386
15193.23
122.2.29:SITC of 100W LED Flood Light luminiare fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =100 watt +/- 5% (b) Luminaire Efficacy=100 Lm/w (c) Power Factor=0.95 (d) Protection Class- IP-66
4
28500
7125.22
122.2.39:S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt =95 (c)Power Factor =0.95
4
1859
464.89
OD30305/2023-2024:Supply of 16 sq mm ISI marked FRLS PVC insulated, single core copper conductor cable
19
4807
253
Approved rates E&M
-
-
-
OD30306/2023-2024:Supply installation testing and commissioning of Electrical Horizontal centrifugal pump set with non-clog / mf impeller to handle storm/mixed/sewage water with having min. discharge of 800 M³/ Hour at head min 7 mtr, RPM 750 having suction and delivery size 350 mm or 300 mm dia, mounted on a common base frame coupled with min 40 HP or suitable rating(IE-2) three phase , TEFC AC , 415 volts , 50 HZ supply electrical motor energy efficient complete as required.Mounted on a common base frame as Casing CI , Impeller CI,Shaft & sleeve (SS) 40 C 8 complete with coupling guard and foundation bolts etc. as reqd.
2
1172551
586275.99
OD30307/2023-2024:P & F/Replacement of M.S Black pipe (9.5 mm thickness) Conforming to IS:3589 with required nut bolts and packing sheet etc complete as reqd of following dia 400 mm ,9.5 mm thickness
14
354662
25333.01
OD30308/2023-2024:P & F/Replacement of M.S Black pipe (9.5 mm thickness) Conforming to IS:3589 with required nut bolts and packing sheet etc complete as reqd of following dia 350 mm ,9.5 mm thickness
10
132829
13282.99
OD30309/2023-2024:P & F/Replacement of M.S Black pipe (9.5 mm thickness) Conforming to IS:3589 with required nut bolts and packing sheet etc complete as reqd of following dia 300 mm ,9.5 mm thickness
4
48280
12070
OD30310/2023-2024:Providing & Fixing of M.S Flange with required nut bolts and packing sheet etc complete as required of following dia. 400 mm ( 25 mm thickness)
17
75752
4456
OD30311/2023-2024:Providing & Fixing of M.S Flange with required nut bolts and packing sheet etc complete as required of following dia. 350 mm ( 25 mm thickness)
10
36770
3677
OD30312/2023-2024:Providing & Fixing of M.S Flange with required nut bolts and packing sheet etc complete as required of following dia. 300 mm ( 25 mm thickness)
9
27288
3032
OD30313/2023-2024:Providing & Fixing of M.S Blind Flange with required nut bolts and packing sheet etc complete as required of following dia. 400 mm ( 25 mm thickness)
1
6940
6940
OD30314/2023-2024:Providing & Fixing of M.S Bend with required nut bolts and packing sheet etc complete as required of following dia. 400 mm(10 mm thick),length 0.75 m
4
23599
5899.99
OD30315/2023-2024:Providing & Fixing of M.S Bend with required nut bolts and packing sheet etc complete as required of following dia. 350mm(8 mm thick),length 0.75 m
2
9600
4800
OD30316/2023-2024:Providing & Fixing of M.S Bend with required nut bolts and packing sheet etc complete as required of following dia. 300 mm(08 mm thick),length 0.75 m
2
7730
3865
OD30317/2023-2024:Replacement of swing type Non Return Valve of CI Body with Door, bronze to Rubber rings confirming to IS 5312(Part 1 & 2), PN 1.6 complete as required NRV 350 MM
2
355520
177760
OD30318/2023-2024:Replacement of swing type Non Return Valve of CI Body with Door, bronze to Rubber rings confirming to IS 5312(Part 1 & 2), PN 1.6 complete as required NRV 150 MM
1
32317
32317
OD30319/2023-2024:Replacement of Non Rising Spindle Sluice Valve of CI Body with Wedge, Bronze ring confirming to IS 14846 & SS IS:6603 (ISI Marked), PN 1.6 complete as required: SV 350 MM
2
465280
232640
OD30320/2023-2024:Rubber Sheet 10 mm thick
100
7300
73
OD30321/2023-2024:Mounting pad(AVM)
18
35928
1996
OD30323/2023-2024:Providing & Fixing of MS Bar Screen made out of MS channel size 4" x 2" (100 mm x 50 mm) and center covered with MS Flat size 80 x 8 mm duly welded with center to center distance 40 mm and back side supporting channel (100 x 50 mm)duly welded .Work also includes complete bar screen fixing in the drain with the help of heavy crane and complete bar screen duly painted with enamel paint. Bar screen duly fixed in side wall using mortar , tools and tackles. (sq feet)
28
67536
2412
OD30324/2023-2024:S/I/T/C of fully automatic Auto Transformer Starter will be made out / fabricated with 2 mm thick, MS sheet steel ,dust & vermin proof, darn & drip-proof , front operated , self supported, free standing type constructions and will be duly spray painted Sythetic Enamel of light grey shade 631 of IS:5 and accomodate all switch gear items required to meet the technical requirements of ATS 50 HP & Adequate rating Oil immersed Auto Transformer having Copper winding , class 'E' insulation with taping 50%,65%&80%(01 No.)Adequate rating power contactors , Overload relay, Single Phase preventer relay with under voltage & over voltage or as suitable(01 No), Flush mounting type ammeter 96 sqmm with selector switch suitable CT connection (01 No), Voltmeter 96 sqmm with selector switch (01 No), Indicating lamp for ON,OFF,TRIP(03 Nos),Indicating lamp for R,Y,B (03 Nos) without transformer's oil as follows: (1) Switch fuse unit 125 A TPN with handle FN 125 A-1 No.(2) HRC fuse 125 A-3 Nos (3) Star contactor coil voltage 240AC with 2 No +2NC AUX. contacts Block MNX 50- 1No.(4)TAP contactor coil voltage 240AC with 2 No +2NC AUX. contacts Block MNX 50- 1No.(5)Line contactor coil voltage 240AC with 2 No +2NC AUX. contacts Block MNX 50- 1No.(6) Over load relay range -A CT operated 45-75 A MN5-01 No(7) Current Transformer 15 VA , CL. 1 for Metering 100//5A-3 No.(8) Push button start/stop element 22.5 mm dia -2 Nos(9) Indicating lamps 230V AC Red LED Type -3 No(10) MCB 6A 1P MCB , 10 KA -1 No.(11) On Delay Timer 0-30 Sec , Coil voltage 240 V , AC 2AODTS-3 Nos(12) Ammeter ,0-100/5a,(100-600A) Sappress Scale 6-Time,96 Sq. mm with Ameter Selector switch 0-100/5A-1 No . (13) Voltmeter 0-500 V ,96 SQMM size with voltage selector S96-1 No.(14) Single Phase preventer relay with under voltage S2VMR2 1 No
2
376527
188263.99
OD828/2024-2025:SITC of Pump- Non clog sewage solid handling - Suc/Del size 150 mm x 150 mm head 15 mtr & discharge 400 m3/hr , Body-CI, Impeller -SS, Shaft- EN-8, Sleeve-SS with coupling, base frame, fuel tank & leads coupled with 38 BHP diesel engine,1500 RPM , Self start, water cooled with radiator complete with 12 V battery as required
1
790698
790698
OD829/2024-2025:SITC of 4 pole 320 Amp oFF load side handle change over switch conforming to IS: 13947 (Part I & III) in sheet steel enclosure i/c connection etc. complete as required.
2
43790
21895
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements