Municipal Corporation Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Municipal Corporation Tender

Works
Electrical and Electronics
Eprocure
Opening Date11 May 2022
Closing Date19 May 2022
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling of existing 3 nos cooling tower and changing the following defective parts : ( a) PVC Fills - (600 mm X 300 mm X 150 mm)- 200 nos. (b) PVC Eliminator - ( 600 X 600 X !50)- 10 nos. (c ) PVC Header pipe 200mm 8' long - 1 no. (d) PVC sub header pipe 63 mm 8' long - 20 nos. (e) PVC sub header end cap 63mm - 30 nos. (f) PVC splash cap with steel screw - 50 nos. (g) PVC 200 mm END cap - 2 nos. (h) PVC nozzle connection 40 mm 1' - 60 nos. (j) Sealing compound- 20 kg (h) FRP stiching material - 20 kg (k) Cast aluminium fan assembly - 2 nos. (l) Labour charges for dismantling, changing defective parts and reinstallation. (m) Cooling tower motors -2 nos. 1

1

-

-

... More
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. (a) 100mm dia. (32 mm thick insulation)

10

-

-

... More
(b) 80 mm dia (32mm thick insulation)

20

-

-

... More
(c) 65 mm dia (32 mm thick insulation)

20

-

-

... More
(d) 50 mm dia ( 32 mm thick insulation)

50

-

-

... More
(e) 40 mm dia ( 32 mm thick insulation)

50

-

-

... More
(f) 32 mm dia(19 mm thick insulation)

120

-

-

... More
(g) 25 mm dia ( 19 mm thick insulation)

50

-

-

... More
Descaling of condensor of 120 TR AC Plant with Vaniclean, recirculating the same to remove the scale including changing rubber gasket of end covers including complete testing etc as required.

3

-

-

... More
Supplying, laying, fixing, testing and commissioning of following thickness closed cell elastrometric nitrile rubber of class 'O' applied by suiatable adhesive, as per specifications and as required complete in all respect. (a) 32 mm

200

-

-

... More
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

4

-

-

... More
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.

4

-

-

... More
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. (a) Thickness 0.80 mm sheet

4

-

-

... More
Servicing of FCU"s installed at various locations in the hospital i/c cleaning of filters, cleaning of choked drain lines / cleaning of coils with the help of vaniclean .

65

-

-

... More
Repairing of Primary Chilled water pump of 7.5 HP with changing of mechanical seal, alignment, balancing complete testing , commissioning etc as required.

1

-

-

... More
Repairing of Primary Chilled water pump of 5 HP with changing of mechanical seal, alignment, balancing complete testing , commissioning etc as required.

1

-

-

... More
Repairing of Defective PCB of chiller machine screw compressor of 120 TR (Carrier make) i/c complete testing , commissioning etc as required.

3

-

-

... More
Supply & pouring of synthetic oil with viscosity grade 220 for topping up the oil level suitable for screw compressor of 120 TR (Carrier make) complete as reqd.

60

-

-

... More
Changing of syphon of size 3/8" in pipeline i/c testing , commissioning complete etc as required.

24

-

-

... More
Changing of 4" dia pressure gauges installed in existing pipeline i/c complete testing , commissioning as required.

24

-

-

... More
Top up of R-134A refrigerant in the chilling machine i/c complete testing commissioning as required.

100

-

-

... More
Painting of MS Pipe Line of various sizes installed at various locations applying a coat of red oxide before aplying 2 coats of paints. (a) 150 to 200 mm dia

200

-

-

... More
(b) 65 to 100 mm dia

100

-

-

... More
(c ) 25 to 50 mm dia

250

-

-

... More
Supply & Fixing of Pre-filter constructed in Aluminium Frame with HDPE mesh and supporting aluminium mesh withepoxy sealed & filtration efficiency 99% down to 5 micron particles as reqd. in the existing opening / AHU of following size. 610 x 610 x 50 MM

10

-

-

... More
Supply & Fixing of Hepa filter constructed in Aluminium Frame with HDPE mesh and supporting aluminium mesh withepoxy sealed & filtration efficiency 99% down to 5 micron particles as reqd. in the existing opening / AHU of following size. (a) 610 x 610 x 305 MM

2

-

-

... More
(b) 610 x 305 x 305 MM

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.