Municipal Corporation Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Municipal Corporation Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date16 Dec 2024
Closing Soon26 Dec 2024
Tender Amount₹ 27,49,971
Costs
EMD
₹ 55,676Document Cost
₹ 590Tender Fee
Refer Documents
Summary
Improvement And Development Of Lighting Arrangement At Pink Apartment In Sector 18 Dwarka In Ward No 121 Dwarka-a Under Najafgarh Zone.nitno.19-02
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MCD_219675_2Tender No
EEE/NGZ/MCD/2024-2025/19Tender Authority
Municipal Corporation ViewPurchaser Address
-Website
http://etenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
5.12:Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
48
286
13761.6
... More
5.18:Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
1465
41
61222.35
... More
7.5.1:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of
following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
1415
36
51873.9
... More
7.6.1:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of
following size in the existing masonry open duct as required.Upto 35 sq. mm
50
27
1398.5
... More
14.16.1.a:Supplying and laying of following size DWC HDPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 em below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal)
200
247
49400
... More
12.42:Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
42
2661
111800.64
... More
Civil DSR
-
-
-
... More
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
5
6259
31295.55
... More
Approved Item
-
-
-
... More
122.1.2:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm
1415
95
134736.3
... More
122.1.30:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-4C*25 sqmm
50
237
11864
... More
122.2.10.a:Providing and laying in position M25 grade reinforced cement concrete foundation of size 450 mm (L) ×450 mm wide and 1000 mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia- 960 mm long(approx)-8 nos. and reinforcement of cold twisted bars of 8 mm dia- 1400 mm (approx) -6 nos.(with 150 mm spacing) as required with supplying and positioning of 4 nos. foundation bolts 16 mm dia,600 mm long, J type i/c 2 nos. template anchor plates of size 225mm×225mm×3mm and providing DWC HDPE for cable entry and exit as required for 3 m and 5 mtr pole.
70
6450
451549.7
... More
122.2.12:Fabrication, supplying and fixing class B galvanised single overhang arm bracket made out of 250mm long galvanised top tube with cap and 1000mm long 40 mm dia galvanised pipe with tightening bolts complete as required.
31
1639
50832.25
... More
122.2.18:Fabrication, supplying and fixing class B galvanised double overhang arm bracket made out of 250mm long galvanised top tube with cap and 1000mm long 40 mm dia galvanised pipes with tightening bolts complete as required.
39
2368
92361.36
... More
122.2.24:Providing and laying of HDPE PIPE OF 40mm outer dia with PN 4 rating by hand Moling/Mannual method Confirming to IS 4984 592
1215
586
712597.5
... More
OD256/2024-2025:Shifting of LED street light fitting from old MS pole to new light pole including connection etc as required.
42
348
14657.58
... More
122.2.4:SITC of Pillar box size 900 mm x 450mm x 250mm suitable for mounting incomer of 250 A MCCB/Main switch 4 Pole and energy meter 3 phase complete with eluotropic grade Aluminium bus bar of size 25mm x 19 mm mounted on galvanized M. S. body power quoted pilferage proof SMC door duly welded with S.S. with rain cover size 40mm x 40mm x 5mm x 600mm height in cutting 300 mm height below ground and covered with shode proof SMC sheet of 3 mm as required.
1
15193
15193.23
... More
OD1381/2024-2025:Fabrication, supply and erection of 5.0 mtr height, minimum 3 mm thick, bottom dia of 130 mm & top dia of 70 mm, base plate of size 225 x 225 x 12 mm thick flange mounted hot dip galvanized octagonal pole made from HT steel plate, window with flash cover with full vertical window cover at appropriate height from the base plate on existing cement concrete pedestal as required. i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window and i/c providing and welding 3 nos. GI strips 4 mm thick of suitable length and having suitable size tapped holes as reqd, terminal block suitable for 25 sq mm conductor- 4 nos. and shorting links on DIN channel i/c providing and fixing DIN channel of suitable length, 6 Amp. SPMCB 'C' curve characteristics, earth stud, cable support clamp suitable for upto 4x25 sqmm cable. Logo/Name of manufacturer shall be either embossed or Riveted plate on the pole. Galvanization as per relevant IS code etc as required.
70
9228
646029.3
... More
OD1382/2024-2025:Fabrication, Supplying, Installation, testing, Commissioning of 12 metres. semi high mast System with its accessories, Mast shaft shall be in one section, hot dip galvanized 4mm thick (Single dip ) inside and out sides and suitable for wind velocity as per IS 875 part3. There shall be in longitudinal seam weld per section and No circufrential weld. It should also included accessories for semi High Mast head frame, 2 point suspension system, 5 × 2.5 sqmm copper conductor with steel wire rope 5mm dia. (7/19 construction) single drum winch, galvanized lantern carriage arrangement suitable for 4/6 Nos. flood light luminaries symmitrically and its control gears boxes and lighting finial, the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC (1:2:4) shallow foundation of size 1m(L) X 1m(W) X 2m deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia -2100 mm long (approx.) - 16 nos.and reinforcement of cold twisted bar of 8 mm dia - 3700 mm (approx.) - 13 nos. (with 150 mm spacing) as required with positioning of foundation bolts and providing DWC HDPE pipe for cable entry & exit as required for high mast considering the safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material i/c, 4Nos S.P MCB, 1 no. double pole 16 Amp MCB etc as reqd. Logo/Name of manufacturer shall be either embossed or rivited plate on the pole. Galvanized as per relevant IS.
1
154138
154138
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%