Municipal Corporation Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Municipal Corporation Tender
Electrical and Electronics
Eprocure
Opening Date12 Jul 2024
Closing Date22 Jul 2024
Tender Amount₹ 8,99,887
Costs
EMD
₹ 17,998Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MCD_201248_1Bid Award Id
ViewTender No
MCD/TR/770/2024_6_1_1/1Tender Authority
Municipal Corporation ViewPurchaser Address
-Website
http://etenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
122.2.2: P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd.
28
20571
734.71
122.2.27:SITC of 30W LED Flood Light luminaire fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =30 watt +/- 5% (b) Luminaire Efficacy=100 Lm/w (c) Power Factor=0.95 (d) Protection Class- IP-66
30
72843
2428.11
122.2.39:S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt =95 (c)Power Factor =0.95
180
83680
464.89
122.2.150.(a):Supply, lowering and fixing following size of G.I. Pipe (M-Class) i/c cutting threading on both sides etc. ISI marked etc as reqd. 25mm(Nominal Bore)
36
9588
266.34
122.2.151.(a):S & F following size of G.I. Socket. as reqd.
25mm
6
760
126.73
122.2.153.(a):S & F following size of G.I. Elbow. as reqd..
25mm
8
1140
142.58
122.2.155.(b):Supply, Installation, testing and commissioning of cubical type control panel board for single phase & Three Phase submersible pumping set of following rating complete with contactor, relay , MCB ,condenser ,voltmeter, ammeter and indication lamp etc including connections etc as reqd.
1.5 HP (Single Phase)
5
21044
4208.91
122.2.156.(a):P&F following sizes of PVC insulated & PVC sheathed copper conductor 3 core submersible cable confirming to IS.694/1990 etc. as reqd.
3x 2.5 sq.mm
120
10693
89.11
122.2.159:Development of tube well with suitable capacity of air compressor i/c lowering of the necessary induction pipe or line i/c cost of fuel, hire charges of compressor etc as reqd. The development shall be considered complete when Gravel stop sinking, Discharge ceased to improve and the sand contents are not more than 10 PPM after 20 minutes of starting the pump complete as reqd.
5
40871
8174.26
122.1.41:Supply of 9 Watt LED retrofit lamp suitable for B22 holder
300
41814
139.38
122.2.42:Repair/Rewinding of existing 1HP mono block pump set including replacement of parts like gun metal bush/ bearing condenser, impeller etc to make the pump functional as required.
16
19801
1237.62
OD24280/2023-2024:Comprehensive AMC (Annual Maintenance Contract) for repair and maintenance of Tube Wells installed in various Municipal Parks. (a) Cost for one tube well with submersible pump set etc of rating up to 1/1.5 HP for one year
14
102802
7343
OD24281/2023-2024:Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) MS flat clamp)
550
30250
55
OD24282/2023-2024:Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. Group C
180
160920
894
OD24283/2023-2024:Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
3
8190
2730
OD24284/2023-2024:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 KA "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with Supplying and fixing brass batten/ angle holder including connection etc. as required. (Single Pole)
50
12800
256
OD24285/2023-2024:S and D following sizes of FR PVC insulated copper conductor,S/C cable in the existying surface/recessed steel/pvc conduit as reqd. Elec6.k 3x2.5Sqmm.
90
12330
137
OD24286/2023-2024:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
90
8549
94.99
OD24287/2023-2024:1.23.1 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 5/6 amps switch
240
12480
52
OD24288/2023-2024:2.14.1 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25A
2
4056
2028
OD24289/2023-2024:1.58 Supplying and fixing PVC batten/angle holder including connections etc. as required.
160
17600
110
OD24290/2023-2024:1.21.2 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
30
4349
144.99
OD24291/2023-2024:1.50.1 Installation of exhaust fan in the existing opening, including making good the damage, connection testing, commissioning etc as required.(upto 450 mm sweep)
46
20700
450
OD24292/2023-2024:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 8 way, Double door
6
15438
2573
OD24293/2023-2024:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amp
26
13702
527
OD24494/2023-2024:Supply of 3 mm thich phenolic laminated sheet
10000
2800
0.28
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements