Municipal Corporation Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Municipal Corporation Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date30 Dec 2024
Closing DateCancelled
Tender Amount₹ 4,62,089
Costs
EMD
₹ 9,517Document Cost
₹ 590Tender Fee
Refer Documents
Summary
Improvement And Development Of Lighting Arrangement In Various Colony In Ward No136 Madhu Vihar Under Ngz.nit/eee/ngz/2024-25/47-01
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MCD_221899_1Tender No
MCD/TR/11493/2024_6_1_1/1Tender Authority
Municipal Corporation ViewPurchaser Address
-Website
http://etenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
7.5.1:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
200
36
7332
... More
5.16:Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
230
70
16152.9
... More
5.1:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
13
5368
69787.64
... More
5.12:Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
35
286
10034.5
... More
14.8:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
1
8136
8136
... More
14.16.1.a:Supplying and laying of following size DWC HDPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal)
150
247
37050
... More
12.42:Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
10
2661
26619.2
... More
Civil Item
-
-
-
... More
110.10:Providing and fiving name board made of MS Sheet 90x60cm, 1mm thick with frame of MS angle 50x50x6mm, two diagonal braces at the back of the sheet of MS flat 40x6mm, total height of the board above ground level 2.40m, length of legs below ground 0.30m embedded in CC block 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) 30x30x45cm including excavation and removal of surplus earth with in 50m lead, applying priming coat of approved steel primer, painting with synthetic enamel paint of approved quality and lettering with enamel paint of approved colour (one side) as per drawing/direction of Engineer-in-Charge
1
7408
7408.8
... More
Approved Items
-
-
-
... More
122.2.24:Providing and laying of HDPE PIPE OF 40mm outer dia with PN 4 rating by hand Moling/Mannual method Confirming to IS 4984 592
30
586
17595
... More
122.2.23:Drilling and laying i/c HDPE pipe of 40 mm outer dia with PN 4 rating by trenchless technology confirming to IS 4984.
20
793
15870
... More
OD8558/2024-2025:Fabrication, supply & erection of 4.0 mtr height, 3 mm thick, bottom dia of 130mm & top dia of 70mm base plate of size 225 x 225 x 12 mm thick flange mounted hot dip galvanized octagonal pole made from HT steel plate, window with flash cover with full verticle window cover at appropriate height from the base plate on existing cement concrete pedestal as required. i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. GI strips 4 mm thick of suitable length and having suitable size tapped holes as reqd, terminal block suitable for 25 sq mm conductor – 4 nos. & shorting links on DIN channel i/c providing and fixing DIN channel of suitable length,, 6 Amp. SPMCB ‘C’ curve characteristics, earth stud, cable support clamp suitable for 4x25 sqmm cable.Logo/Name of manufacturer shall be embosed on the pole, galvanization as per relevant IS code etc as required.
5
8079
40399.95
... More
OD8243/2024-2025:Providing and laying in position M25 grade reinforced cement concrete foundation of size 450 mm(L) x 450 mm wide and 1000 mm deep i/c excavation of earth, providing cutting, bending and placing in position, rewinforcement of cold twisted bars of 12 mm dia -960mm long (approx.) - 8 nos.and reinforcement of cold twisted bar of 8 mm dia - 1400 mm (approx.) - 6 nos. (with 150 mm spacing) as required with supplying and positioning of 4 nos foundation bolts of size 16 mm dia and 600 mm long, J type i/c 2 nos template anchor plates of size 225 mm x 225mm x 3 mm and providing 63 mm DWC HDPE pipe for cable entry & exit as required for 3 m and 5 mtr pole
10
7743
77430
... More
OD8245/2024-2025:Fabrication supplyiing and fixing class B Galvanised single overhang arm bracket made out of 250 mm long galvanized top tube with cap & 250 mm long 32 mm dia galvanized pipe with tightening bolts complete as reqd
6
1380
8280
... More
122.1.2:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm
500
95
47610
... More
OD8546/2024-2025:Supply of 35 watt LED Street Light Luminaire fitted with lens made of pressure die cast aluminum housing and toughened glass cover complete with the following specifications as per relevant IS (a) Total System Wattage :35 Watt + 5% (b) Luminaire Efficacy -120 Lumens/watt ( minimum) (c) Power factor > 0.95 (d) Protection Class IP66 (e) LED Package shall be CeramicBase (f) Multi Chip ,Array Multi Die,Mid Power,intergrated Arrays and COB type LED Chip is not permitted. (g) Operating Current of LED < 70% of rated maximum forward current, limited to a minimum of 350 mA and maximum of 1000 mA. (h) Wattage of LED Package : One watt to Five watt maximum (i) CRI >70 (j) THD<10% for complete fixture (k) Operating Voltage – 110-320 V, 50Hz +/- 3%. (l) The driver must have thermal Protection against 75 deg C ambient temperature with internal SPD of minimum 6 KV. Separate Compartment for Driver (m) Life of Street Light: Minimum 50,000 hrs
15
1994
29910
... More
OD8467/2024-2025:Supply of 140 watt LED Street Light/Flood Light Luminaire fitted with lens made of pressure die cast aluminum housing and toughened glass cover complete with the following specifications as per relevant IS (a)Total System Wattage :140 Watt + 5% (b)Luminaire Efficacy -130 Lumens/watt ( minimum) (c)Power factor > 0.95 (d)Protection Class IP66 (e)LED Package shall be Ceramic Base, (f)Multi Chip ,Array Multi Die,Mid Power,intergrated Arrays and COB type LED Chip is not permitted. (g)Operating Current of LED < 70% of rated maximum forward current, limited to a minimum of 350 mA and maximum of 1000 mA. (h)Wattage of LED Package : One watt to Five watt maximum (i)CRI >70 (j)THD<10% for complete fixture (k)Operating Voltage – 110-320 V, 50Hz +/- 3%. (l)The driver must have thermal Protection against 75 deg C ambient temperature with internal SPD of minimum 6 KV. Separate Compartment for Driver (m)Life of Street Light: Minimum 50,000 hrs
4
5481
21927.96
... More
OD8248/2024-2025:Installation and Commissioning of Street Light etc. as required.
19
339
6445.75
Evaluation Notes How It Works ?