Municipal Corporation Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 42,650Document Cost
₹ 590Tender Fee
Refer Documents
Summary
Nit No 21/eee/kbz/mcd/2024-25 Item No. 04
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MCD_222753_1Tender No
NIT No 21/EEE/KBZ/MCD/2024-25/04Tender Authority
Municipal Corporation ViewPurchaser Address
-Website
http://etenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
5.2:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
10
6855
68550.1
... More
5.12:Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
10
286
2867
... More
5.18:Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
760
41
31760.4
... More
14.16.1.a:Supplying and laying of following size DWC HDPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal)
480
247
118560
... More
Part B Approved Items
-
-
-
... More
OD2370/2024-2025:Providing and Fixing FRP Fencing rust proof, shock proof, anti- corrosive, selfextinguishing, ultra violet stabilized, VOUL94, weather proof, flame retardant, environment friendly, yellow in color installed at electrical installations with necessary concreting for grouting vertical post, hardware, accessories, fitting etc. with minimum 300mm grouting in ground along with 1 number of FRP almirah type double door gates with necessary hardware accessories like stainless steel heavy duty L-Drop, Hinges, screws, nut and bolt, lock fittings, etc. with vertical post of size 50x50x3mm, sub-frame of 50x25x3mm, pickets of size 38x15mm, Cylindrical rods of 12mm dia, hollow section size of not more than 5x5inch and also providing 1 number MS danger plate of size 250x200x2mm,1 number MS name plate of property of MCD and sponsors name as per site requirement. The product should comply the various standards for FRP fencing like IS 13410-ASTM D 2584, D792, D570, D256, D638, D695, D790, D495, D149, D648, IS13360, IS6746. The compliance report of above national/international standard may be referred if required.
60.45
3950
238777.5
... More
122.1.3:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm
350
115
40432
... More
122.2.24:Providing and laying of HDPE PIPE OF 40mm outer dia with PN 4 rating by hand Moling/Mannual method Confirming to IS 4984 592
110
586
64515
... More
OD3060/2024-2025:Fabrication, supply & erection of 5.0 mtr height, 3 mm thick, bottom dia of 130mm & top dia of 70mm base plate of size 225 x 225 x 12 mm thick flange mounted hot dip galvanized octagonal pole made from HT steel plate, window with flash cover with full verticle window cover at appropriate height from the base plate on existing cement concrete pedestal as required. i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. GI strips 4 mm thick of suitable length and having suitable size tapped holes as reqd, terminal block suitable for 25 sq mm conductor – 4 nos. & shorting links on DIN channel i/cpdg and fixing DIN channel of suitable length,, 6 Amp. SPMCB ‘C’ characteristics, earth stud, cable support clamp suitable for Upto 4x25 sqmm cable. Logo/Name of manufacturer shall be embossed on the Pole. Galvanization as per relevant etc as required.
20
9228
184579.8
... More
OD3061/2024-2025:Fabrication, Supplying, Installation, Testing, Commissioning of 12 meters semi high mast System with its accessories, Mast shaft shall be in one section , hot dip galvanized 4mm thick(Single dip ) inside & out sides &suitable for wind velocity as per IS 875 part3. There shall be in longitudinal seam weld per section and No circumferential weld. It should also included accessories For High Mast head frame, 2 point suspension system, 5x2.5 sqmm copper conductor with steel wire rope 5mm dia. (7/19 construction) single drum winch, galvanized lantern carriage arrangement suitable for 4/6 Nos. Flood Light luminaries symmetrically and its control gears boxes and lighting finial, the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC (1:2:4) shallow foundation of size 1m(L) x 1m wide and 2m deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia -2100mm long (approx.) - 16 nos.and reinforcement of cold twisted bar of 8 mm dia - 3700 mm (approx.) - 13 nos. (with 150 mm spacing) as required with positioning of foundation bolts and providing DWC HDPE pipe for cable entry & exit as required for the high mast considering the safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material i/c 4Nos S.P MCB, 1 No Double Pole 16Amp. MCB etc as reqd. Logo/Name of manufacturer shall be embossed Rivited plate on the pole. Galvanization as per relevant IS.
5
154138
770690
... More
122.1.2:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm
360
95
34279.2
... More
122.2.10.a:Providing and laying in position M25 grade reinforced cement concrete foundation of size 450 mm (L) ×450 mm wide and 1000 mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia- 960 mm long(approx)-8 nos. and reinforcement of cold twisted bars of 8 mm dia- 1400 mm (approx) -6 nos.(with 150 mm spacing) as required with supplying and positioning of 4 nos. foundation bolts 16 mm dia,600 mm long, J type i/c 2 nos. template anchor plates of size 225mm×225mm×3mm and providing DWC HDPE for cable entry and exit as required for 3 m and 5 mtr pole.
20
6450
129014.2
... More
122.2.14:Fabrication, supplying and fixing class B galvanised single overhang arm bracket made out of 250mm long galvanised top tube with cap and 1000mm long 32 mm dia galvanised pipe with tightening bolts complete as required.
20
1457
29152.6
... More
OD8292/2024-2025:Supply of 70 watt LED Street light/Flood Light Luminaire fitted with lens made of pressure die cast aluminium housing and toughened galss cover complete with the following specification as per relevant IS. (a) Total system wattage :- 70 Watt+/- 5%, (b) Luminaire efficacy- 130 Lumens/watt minimum, (c) Power factor > 0.95, (d) Protection Class IP-66, (e) LED package shall be Ceramic Base. (d) Multi Chip, Array, Multi Die, Mid Power, integrated Arrays and COB type Chip are not permitted. (g) Operating current of LED< 70% of rated maximum forward current, limited to a minimum of 350 mA and maximum of 1000 mA. (h) Wattage of LED package: One watt to five watt maximum, (i) CRI>70, (j) THD<10% for complete fixture, (k) Operating Voltage- 110-320V, 50Hz+/- 3%, (l) The driver must have thermal Protection against 75 deg C ambient temprature with internal SPD of minimum 6 KV Separate Compartment for Driver. (m) Life of street Light : Minimum 50,000 hrs.
40
3495
139800
... More
OD8293/2024-2025:Supply of 140 watt LED Street light/Flood Light Luminaire fitted with lens made of pressure die cast aluminium housing and toughened galss cover complete with the following specification as per relevant IS. (a) Total system wattage :- 140 Watt+/- 5%, (b) Luminaire efficacy- 130 Lumens/watt minimum, (c) Power factor > 0.95, (d) PROTECTION CLASS IP-66, (e) LED package shall be Ceramic Base. (d) Multi Chip, Array, Multi Die, Mid Power, integrated Arrays and COB type Chip are not permitted. (g) Operating current of LED< 70% of rated maximum forward current, limited to a minimum of 350 mA and maximum of 1000 mA. (h) Wattage of LED package: One watt to five watt maximum, (i) CRI>70, (j) THD<10% for complete fixture, (k) Operating Voltage- 110-320V, 50Hz+/- 3%, (l) The driver must have thermal Protection against 75 deg C ambient temprature with internal SPD of minimum 6 KV Separate Compartment for Driver. (m) Life of street Light : Minimum 50,000 hrs.
30
5481
164459.7
... More
OD8294/2024-2025:Installation and Commissioning of Street Lights / Flood Lights etc. as required.
70
339
23730
... More
Part C Civil Items
-
-
-
... More
4.4.1:Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing.1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
4
7210
28842.12
... More
110.10:Providing and fiving name board made of MS Sheet 90x60cm, 1mm thick with frame of MS angle 50x50x6mm, two diagonal braces at the back of the sheet of MS flat 40x6mm, total height of the board above ground level 2.40m, length of legs below ground 0.30m embedded in CC block 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) 30x30x45cm including excavation and removal of surplus earth with in 50m lead, applying priming coat of approved steel primer, painting with synthetic enamel paint of approved quality and lettering with enamel paint of approved colour (one side) as per drawing/direction of Engineer-in-Charge
5
7408
37044
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%