Municipal Corporation Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Municipal Corporation Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date11 Dec 2024
Closing Date19 Dec 2024
Tender Amount₹ 16,49,836 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
16.2.9:Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class ‘O’ insulation applied by suitable rubber based adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size-80mm dia. (32mm thick nitrile rubber insulation)

3

5061

15183.9

... More
16.2.11:Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class ‘O’ insulation applied by suitable rubber based adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size- 50mm dia. (32mm thick fiber glass insulation) COST

24

1553

37277.76

... More
16.2.13:Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class ‘O’ insulation applied by suitable rubber based adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size-32mm dia. (19mm thick nitrile rubber insulation)

30

1046

31399.5

... More
16.2.12a:Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class ‘O’ insulation applied by suitable rubber based adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 40mm dia. (32mm thick nitrile rubber insulation)

12

1217

14612.04

... More
16.5.1:Supplying, laying, fixing, testing and commissioning of following thickness closed cell elastrometric nitrile rubber of class 'O' applied by suiatable adhesive, as per specifications and as required complete in all respect.Insulation with nitrile rubber of thickness 32mm on existing pipe

48

1120

53774.88

... More
16.7.1.2:Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Butterfly valve (Manual) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/ hot water circulation as specified .BUTTERFLY VALVE (MANUAL) 150mm

6

8353

50121

... More
16.8:Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required

5

1364

6820.2

... More
OD items

-

-

-

... More
OD3130/2024-2025:Top up of Refrigerant (R-134A) in the chiller machine i/c complete testing , commissioning complete as required

50

1500

75000

... More
OD3131/2024-2025:Repairing of Primary Chilled water pump of 5.5 KW/7.5 HP make Kirloskar, rpm 1450, hz 50, 415 V, IP-55 with rewinding, bearing changing of mechanical seal, alignment, balancing complete testing , commissioning as required

1

16000

16000

... More
OD3132/2024-2025: Repairing of secondary Chilled water pump of 7.5 KW / 10 HP make Kirloskar, rpm-1450, hz - 50, 415 V, A - 14.3 with rewinding, bearing, changing of mechanical seal, alignment, balancing complete testing , commissioning as required

2

18799

37599.98

... More
OD3133/2024-2025:Servicing of FCU"s installed at various locations in the hospital i/c cleaning of filters, cleaning of choked drain lines / cleaning of coils with the help of veniclean. capacity 1.5 ton - 2 ton, make - HI-Tech Engineers.

36

2500

90000

... More
OD3134/2024-2025: Descaling of condenser of 250 TR AC Plant with Vaniclean, recirculating the same to remove the scale including changing rubber gasket of end covers including complete testing complete as required.

3

30000

90000

... More
OD3135/2024-2025:Descaling and washing of cooling coil of AHU with the help of vaniclean chemical, greasing the blower motor, testing complete etc as required. capacity 2500 - 3000 CFM. make - ADGETECH

8

11000

88000

... More
OD3136/2024-2025:Providing and applying Star Bond adhesive for protection to insulated ducting with the help of brush to make the solid leak proof from various joints etc as required. It is a protective coating of insulation which can bear temperature upto 112 degree Celsius, colour white viscocity @ 30 degree celsius - 65000 CPS, specify gravity 1.4

32

517

16575.68

... More
OD3137/2024-2025:Supplying, Installation, Testing & Commissioning of Oil Tranducer to be installed in Carrier Make Chiller Machine i/c Testing, Commissioning Complete as Required for 120 TR chiller machine and as per OEM standards.

2

20000

40000

... More
OD3138/2024-2025:Supplying, Installation, Testing & Commissioning of Oil Filter (Internal) for Carrier Make Chiller Machine i/c Testing, Commissioning Complete as Required for 120 TR chiller machine and as per OEM standards.

2

28000

56000

... More
OD3139/2024-2025:Supplying, Installation, Testing & Commissioning of Oil Filter (External) for Carrier Make Chiller Machine i/c Testing, Commissioning Complete as Required for 120 TR chiller machine and as per OEM standards.

3

29200

87600

... More
OD3140/2024-2025:Supplying, Installation, Testing & Commissioning of Oil Level Switch to be installed in Carrier Make Chiller Machine i/c Testing, Commissioning Complete as Required for 120 TR chiller machine and as per OEM standards.

1

83000

83000

... More
OD3141/2024-2025:Supplying, Installation, Testing & Commissioning of synthetic screw Compressor Oil (Approx 50 Ltr.) Carrier Make for Chiller Machine i/c Testing, Commissioning Complete as Required.

1

130500

130500

... More
OD3142/2024-2025:Supplying, Installation, Testing & Commissioning of Display Card of Carrier Make Chiller Machine i/c Testing, Commissioning Complete as Required for 120 TR chiller machine and as per OEM standards.

1

178000

178000

... More
OD3143/2024-2025:Supplying, Installation, Testing & Commissioning of PD4-EXV 32 GB, 500, 192 EE Card to be installed in Carrier Make Chiller Machine i/c Testing, Commissioning Complete as Required for 120 TR chiller machine and as per OEM standards.

1

81900

81900

... More
OD3144/2024-2025:Supplying, Installation, Testing & Commissioning of PDS-SCPM3 Card Chiller to be installed in Carrier Make Chiller Machine i/c Testing, Commissioning Complete as Required for 120 TR chiller machine and as per OEM standards.

2

110600

221200

... More
122.2.150.(b):Supply, lowering and fixing following size of G.I. Pipe (M-Class) i/c cutting threading on both sides etc. ISI marked etc as reqd. 32mm(Nominal Bore)

15

320

4811.85

... More
122.2.151.(b):S & F following size of G.I. Socket. as reqd. 32mm

6

163

980.22

... More
122.2.153.(b):S & F following size of G.I. Elbow. as reqd.. 32mm

3

205

617.82



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.