Military Engineer Services Tender
... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Maintenance And Repairs Of Dg Sets Of Fire Fighting And Water Supply Installations Of Camero Area Under Ge (af) Subroto Park in New Delhi, Delhi, with an estimated contract value of Rs. 16,40,000. The bid opening date for this tender is 06-11-2026 and the last date for bid submission is 20-11-2026. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Military Engineer Services - MES Tender - Delhi Tender
Opening Date6 Nov 2026
Closing Soon20 Nov 2026
Tender Amount₹ 16,40,000
Costs
EMD
₹ 32,800Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Maintenance And Repairs Of Dg Sets Of Fire Fighting And Water Supply Installations Of Camero Area Under Ge (af) Subroto Park
Description
As Described In Bill Of Quantities
Contact
Tender Id
2026_MES_792156_2Tender No
GE/SP/TOKEN-62/2026-27Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Schedule of credit, schedule A Notes, Special conditions, Particular specifications and other connected documents
BOQ Items
... More
D. G . Set 160 KVA, Make: Ashoka leyland ,Location : AFCME FF
9
-
-
... More
D. G . Set 125 KVA, Make: Kirloskar, Location : Near MAP -364 Bldg
9
-
-
... More
D. G . Set 100 KVA, Make: Ashoka Leyland, Location : AFRO FF Pump House
9
-
-
... More
D. G . Set 30 KVA, Make: Jacksons , Engine Make :- Cummins , Location : Sabji Mandi Pump House
9
-
-
... More
D. G . Set 30 KVA, Make: Kirloskar , Location : WAC (U) Building
9
-
-
... More
Diesel engine fire pump 62 HP, Make: Kirloskar , Location : WAC (U) Building
9
-
-
... More
Supply only diesel filter element with O ring, suitable for following capacities of DG sets :-
-
-
-
... More
D. G . Set 30 KVA
2
-
-
... More
D. G . Set 100/125 KVA
2
-
-
... More
D. G . Set 160 KVA
4
-
-
... More
D. G . Set 250 KVA
1
-
-
... More
Diesel engine fire pump 62 HP
1
-
-
... More
Supply only oil filter element with O ring, suitable for following capacities of DG sets :-
-
-
-
... More
D. G . Set 30 KVA
2
-
-
... More
D. G . Set 100/125 KVA
2
-
-
... More
D. G . Set 160 KVA
4
-
-
... More
D. G . Set 250 KVA
1
-
-
... More
Diesel engine fire pump 62 HP
1
-
-
... More
Supply only by pass filter element with O ring suitable for following capacities of DG sets :-
-
-
-
... More
D. G . Set 30/100/125 KVA
2
-
-
... More
D. G . Set 160/250 KVA
1
-
-
... More
Supply only air filter element suitable for following capacities of DG sets :-
-
-
-
... More
D. G . Set 30 KVA
2
-
-
... More
D. G . Set 100/125 KVA
2
-
-
... More
D. G . Set 160 KVA
4
-
-
... More
D. G . Set 250 KVA
1
-
-
... More
Diesel engine fire pump 62 HP
1
-
-
... More
Supply only fan belt suitable for following capacities of DG sets:-
-
-
-
... More
D. G . Set 30 KVA
2
-
-
... More
D. G . Set 100/125 KVA
1
-
-
... More
D. G . Set 160 KVA
2
-
-
... More
D. G . Set 250 KVA
1
-
-
... More
Supply only battery charging alternator belt suitable for following capacities of DG sets :-
-
-
-
... More
D. G . Set 30 KVA
2
-
-
... More
D. G . Set 100/125 KVA
1
-
-
... More
D. G . Set 160 KVA
2
-
-
... More
D. G . Set 250 KVA
1
-
-
... More
Supply only rubber hose pipe set for water circuit complete with clamps, suitable for following capacities of DG sets :-
-
-
-
... More
D. G . Set 30 KVA
2
-
-
... More
D. G . Set 100/125 KVA
1
-
-
... More
D. G . Set 160 KVA
2
-
-
... More
D. G . Set 250 KVA
1
-
-
... More
Supply and fixing in replacement PVC insulated multisranded , copper conductor 70 sqmm multistranded of 1.25 mtr long battery leads each duly fixed with brass clamps, copper lugs suitable for DG sets installed at different locations .
5
-
-
... More
Supply only engine oil, multi grade 20w / 40.
150
-
-
... More
Supply only coolant all as specified and as directed by the Engineer-In- Charge.
60
-
-
... More
Supply and applying Petroleum jelly.(1 kg plastic sealed container.)
1
-
-
... More
Supply and fill in batteries distilled water for topping up
50
-
-
... More
M & L for Dismantling of radiator , taking it to work shop for overhauling & cleaning descaling with acid removal of leakage, welding brazing & refixing it duly repaired etc all as directed by Engineer- in- Charge
-
-
-
... More
D. G . Set 30 KVA
1
-
-
... More
D. G . Set 100/125 KVA
1
-
-
... More
D. G . Set 160/250 KVA
1
-
-
... More
Calibration of FIP and injectors from the authorised dealer including petty repairs to make the FIP functional for the following capacities of DG sets including necessary spares required for smooth functioning of FIP :- Note : A Certificate to the effect that the calibration and repairs has been carried out by the authorised dealer shall be submitted by the contractor.
-
-
-
... More
D. G . Set 100/125 KVA
1
-
-
... More
D. G . Set 160/250 KVA
1
-
-
... More
M&L for tappet setting of following capacities of DG sets.
-
-
-
... More
D. G . Set 30 KVA
1
-
-
... More
D. G . Set 100/125 KVA
1
-
-
... More
D. G . Set 160/250 KVA
1
-
-
... More
Supply only Oil Sump packing set suitable for following DG sets
-
-
-
... More
D. G . Set 30 KVA
1
-
-
... More
D. G . Set 100/125 KVA
1
-
-
... More
D. G . Set 160/250 KVA
1
-
-
... More
Supply and fix solenoid valve suitable for following capacity DG sets
-
-
-
... More
D. G . Set 30/100/125 KVA
2
-
-
... More
D. G . Set 160/250 KVA
1
-
-
... More
M&L for repair / overhauling of self starter incl. replacement of carbon brushes, bearing, bushes, rewinding of armature and field etc. and varnishing complete all as directed for the following capacity :-
-
-
-
... More
24 Volts
1
-
-
... More
12 Volts
1
-
-
... More
Supply & Fix in replacement self starter for suitable of 30 KVA DG set capacity including all necessary electrical connections complete all as specified and as directed by the Engineer-In- Charge.
1
-
-
... More
Supply & Fix in replacement self starter for suitable of 100 KVA to 125 KVA DG set capcity including all necessary electrical connections complete all as specified and as directed by the Engineer-In- Charge.
1
-
-
... More
Supply & Fix in replacement self starter for suitable of 160 KVA to 250 KVA DG set DG set capcity including all necessary electrical connections complete all as specified and as directed by the Engineer-In- Charge.
1
-
-
... More
Supply and fix in repair automatic voltage regulator up to 125 KVA as directed by Engineer-In-Charge.
1
-
-
... More
Supply and fix in repair automatic voltage regulator above 160 KVA upto 250 KVA as directed by Engineer-In-Charge.
1
-
-
... More
Supply and fix in repair control wiring of the DG set up to 125 KVA complete incl provision of additional auto cables heavy duty suitable for Gen set application .
1
-
-
... More
Supply and fix in repair control wiring of the DG set above 160 KVA up to 250 KVA complete incl provision of additional auto cables heavy duty suitable for Gen set application .
1
-
-
... More
M & L for Top Overhauling only of DG set capacity 100/ 125/160 KVA of Kirloskar/Ashoka Leyland make and including replacement of gaskets etc complete all as specified and all spare parts required to complete the work to the satisfaction of Engineer-in-charge .
1
-
-
... More
Supply & Fix in replacement 24 Volts SMPS battery Charger complete all as specified and as directed by the Engineer-In- Charge.
1
-
-
... More
Supply & Fix in replacement 12 Volts SMPS battery Charger complete all as specified and as directed by the Engineer-In- Charge.
1
-
-
... More
Supply and fix in replacement lead acid maintenance free battery 180 AH, 12 V, complete all as specified and as directed by the Engineer-In- Charge.
3
-
-
... More
Supply and fix in replacement lead acid maintenance free battery 150 AH ,12 Volt complete all as specified and as directed by the Engineer-In- Charge.
3
-
-
... More
Supply and fix in replacement lead acid maintenance free battery 88 AH ,12 Volt complete all as specified and as directed by the Engineer-In- Charge.
1
-
-
... More
Supply & Fix in replacement of digital multi function meter to read voltage, current and power factor complete all as specified and as directed by the Engineer-In- Charge.
3
-
-
... More
Supply & Fix in replacement of 3 pole power contactor MNX 265 complete all as specified and as directed by the Engineer-In- Charge.
1
-
-
... More
Supply & Fix in replacement of 3 pole power contactor MCX 33,160 Amp complete all as specified and as directed by the Engineer-In- Charge.
1
-
-
... More
M & L for wiring of AMF panel suitable upto 125/160 KVA DG set complete all as specified and directed by engineer in charge.
Note : wire, thimble and necessary item required also included in the unit quoted rate.
1
-
-
... More
Supply & Fix in replacement of solenoid switch suitable including all necessary arrangement complete all as specified and as directed by the Engineer-In- Charge.
3
-
-
... More
S&F in replacement belt for water pump ( set ) in 125- 250 KVA DG set for greevs complete all as specified and as directed by the Engineer-In- Charge.
2
-
-
... More
S&F in replacement belt for water pump ( set ) in 30-100 KVA DG set complete all as specified and as directed by the Engineer-In- Charge.
2
-
-
... More
S&F in replacement PCB 24 Volt DC with engine start stop relay suitable for 160 KVA DG Set complete all as specified vol and as directed by the Engineer-In- Charge.
1
-
-
... More
S&F in replacement stopper switch 24 Volt DC suitable for 160 KVA DG Set complete all as specified vol and as directed by the Engineer-In- Charge.
1
-
-
... More
S&F in replacement PCB 12 Volt DC with engine start stop relay suitable for 30-125 KVA DG Set complete all as specified vol and as directed by the Engineer-In- Charge.
2
-
-
... More
S&F in replacement stopper switch 12 Volt DC suitable for 30-125 KVA DG Set complete all as specified vol and as directed by the Engineer-In- Charge.
2
-
-
... More
Supply and fix oil safety switch to engine of 30 KVA to 125 KVA DG set KVA DG set as per existing complete all as specified and as directed by the Engineer-In- Charge.
2
-
-
... More
Supply and fix oil safety switch to engine of 160 KVA to 250 KVA DG set DG set as per existing complete all as specified and as directed by the Engineer-In- Charge.
1
-
-
... More
Supply and fix in replacement the corrosion resistor as per existing to the Engine of DG set of any capacity complete all as specified and as directed by the Engineer-In- Charge.
3
-
-
... More
S & F start and stop relay 12 V/24 V DC suitable for AMF Panel of any capacity of all as per manufacturers recommendations and complete all as specified and as directed by the Engineer-In- Charge.
3
-
-
... More
S & Fix in repairs Low lub oil pressure sensor for 100 to 250 KVA DG set and connecting with DG set system complete all as specified and as directed by the Engineer-In- Charge.
2
-
-
... More
S & Fix in repairs temperature sensor for 100 to 250 KVA DG set and connecting with DG set system complete all as specified and as directed by the Engineer-In- Charge.
2
-
-
... More
Supply and fix in replacement Lub oil hoses set including neceaary clamps, nut ,bolts and washer for DG set of any capacity complete all as specified and as directed by the Engineer-In- Charge.
4
-
-
... More
Supply and fix in replacement DG set controller for 100 KVA/125KVA/160KVA DG set , complete all as specified and as directed by the Engineer-In- Charge.
1
-
-
... More
Supply & fix in replacement of MCCB 160 amps 4/3 pole 25 KA 415 volts 50 Hz complete all as specified and as directed by Engineer-in-charge.
1
-
-
... More
Supply & fix in replacement of MCCB 125 amps 4/3 pole 16 KA 415 volts 50 Hz complete all as specified and as directed by Engineer-in-charge.
2
-
-
... More
Supply & fix in replacement of MCCB 250 amps 4/3 pole 35 KA 415 volts 50 Hz complete all as specified and as directed by Engineer-in-charge.
1
-
-
... More
Supply & fix in replacement of Under Voltage relay E-210 ,suitable for 440 Volt complete all as specified and as directed by Engineer-in-charge.
3
-
-
... More
Supply & fix in replacement of on delay timer suitable for 230 Volt AC complete all as specified and as directed by Engineer-in-charge.
2
-
-
... More
M & L for replacement of unserviceable hinges of DG set canopy doors with the new SS hinges heavy grade including welding /screwing as required on site complete all as specified and directed.
10
-
-
... More
Design, supply, install, test & commissioning of factory made AMF Panel suitable for carrying current up to 110% of full load of 250 KVA DG set , having IP 54 protection, Out door, free standing, floor mounted, dust and vermin proof, cubical type, made out of CRCA sheet 3.15 mm thick and shall be painted with epoxy powder paint by means of electro static gun after rigorous pretreatment comprising of cold phosphating process on all internal and external surfaces after due preparation of surfaces, totally enclosed with front and rear opening, hinged doors, locking arrangements. Control panel shall be provided with suitable internal wiring with copper cable of suitable size, main contactors with 415 Volt coil, switch gears (4 pole MCCB in incoming main supply & DG set supply and out going with Ics = 100% Icu) , copper bus bars with colour coded heat shrinkable PVC sleeves with suitable inter connecting copper wire DG supply and main supply / copper strips, control wires, relays, timers, bakelite control fuses, measuring devices such as Voltmeter, Ammeters both for AC & DC, mulitifunction meter for displaying various parameters of DG sets all as required & current transformer of suitable ratio, Selector switches, HRC fuses, earth bus and bolts etc. The panel shall be with standard functional system with necessary accessories for automatic start of DG set on main supply failure and stop when mains restore after necessary cooling. The control panel shall be provided with standard over load, earth fault relay, indicating lamps and manual control switches / push button switches for DG Set ON / OFF, DG Contactor ON / OFF, Mains Contactor ON / OFF, RESET, ACK, TEST, TRIP with indicating lamps, including battery charging system with rectifier bridge, transformer of suitable size and capacity to charge batteries trickle / boost and unbalanced voltage tripping system all as specified including taking out of old panel complete all as specified and as directed by the Engineer - in - Charge.
Note : (i)The Out door AMF panel shall be with by pass arrengements with on load chageover switches-02 Nos of same rating as per MCCB.
(ii) The contractor to submit the drawing of panel for approval of accepting authority.
1
-
-
... More
Material and labour in replacement of aluminium cable lugs/thimbles with suitable size of nut bolt and double washer for UG cable size 240-400 Sqmm including complete connection and crimping complete all as specified and directed.
15
-
-
... More
All as per Item No 59 above but for UG cable size 120-185 Sqmm.
15
-
-
... More
All as per Item No 59 above but for UG cable size 95 Sqmm.
15
-
-
... More
All as per Item No 59 above but for UG cable size 70 Sqmm.
15
-
-
... More
All as per Item No 59 above but for UG cable size 50 Sqmm.
15
-
-
... More
All as per Item No 59 above but for UG cable size 35 Sqmm.
15
-
-
... More
Supply, Laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with aluminium conductor of cross sectional area 35 sqmm 3.5 core with all fixing & connecting accessories including taking down old unserviceable cable.
100
-
-
... More
All as per Item No 65.00 here-in-before but 50 sqmm 3.5 core
80
-
-
... More
All as per Item No 65.00 here-in-before but 95 sqmm 3.5 core
80
-
-
... More
All as per Item No 65.00 here-in-before but 120 sqmm 3.5 core
80
-
-
... More
All as per Item No 65.00 here-in-before but 400 sqmm 3.5 core
75
-
-
... More
Excavation in trenches in hard and dense soil n exc 1.5 mtr wide and n.exc 1.5 mtr in depth for laying of pipe,foundation for poles, stay, laying cables etc and getting out copmlete all as directed by engineer-in-charge.
41
-
-
... More
Returning filling in including spreading, leveling watering and well ramming in layers n. exc 25 cm in hard/dense soil copmlete all as directed by engineer-in-charge.
25
-
-
... More
Removing excavated material n.exc 50 meters and depositing where directed at a level n.exc 1.5 meter above the starting point copmlete all as directed by engineer-in-charge.
16
-
-
... More
M&L for Sand cushioning of cables provided with a layer of sand 8 cm deep before laying the cable and 15 cm depth after punning down and stretching the cable copmlete all as directed by engineer-in-charge.
12
-
-
... More
Supply and laying reinforced precast concrete cable cover class LV ,type I,flat ,size 250mmx150mmx 40 mm for cable protection over cable perpendicular to direction of cable per complete all as specified and directed.
900
-
-
... More
Supply and laying GI pipe light grade galvanized with all fittings as required laid in trenches or fix on wall/pole for cable protection of 80 mm bore copmlete all as directed by engineer-in-charge.
15
-
-
... More
Supply & fix in repairs MCCB 400 Amp,4 Pole,36 KA rupturing capacity ,Ics=100%Icu-01 No in sheet steel enclosure made out of 2mm thick CRCA sheet duly powder coated indoor type having cable end boxes 2 nos,lugs,gland with angle iron frame made of 50X50X6mm ,200mm below grond & 600mm above ground with PCC including taking out of LT cable 400 sqmm from existing panel& reconnceting the same complete all as specified and directed.
1
-
-