Military Engineer Services Tender

... More
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date18 Feb 2025
Closing Soon18 Mar 2025
Tender Amount₹ 48,12,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All description as per srl item No 3 here- in- before but using cable size 1.5 Sqmm for 1 Nos 05 Amps Socket outlet independent with terminal boxes, Moduler fittings including acessories as moduler surface cover plate with frame, metal flush box,complete all as specified and as dierected.

25

-

-

... More
All description as per srl item No 3 here- in- before but using cable size 1.5 Sqmm for 05 Amps Socket outlet independent but below the switch board with terminal boxes, Moduler fittings including acessories as moduler surface cover plate with frame, metal flush box complete all as specified and dierected.

20

-

-

... More
All description as per srl item No 3 here- in- before but using cable size 1.5 Sqmm for 1 Nos 05 Amps Socket outlet on the same board with other switches complete all as specified and as dierected.

20

-

-

... More
All as per srl item No 3 here- in- before but using cable size 2.5 Sqmm for 15 Amps Socket outlet terminal boxes for Modular switches including acessories as moduler surface cover plate with frame, metal flush box with 2.5 sqmm earth wire complete all as specified and as dierected.

25

-

-

... More
M&L for Point wiring with 1.5 Sqmm multistranded copper conductor cable multistranded, FRLSH PVC insulated and unsheathed in PVC casing & caping double lock including fixures and terminal boxes with all fittings /accessories and including 1.5 Sqmm PVC insulated copper earth wire connected common earth with terminal boxes for Modular fittings including acessories as modular surface cover plate with frame, for one light/Fan/Exhaust Fan/bell point complete all as specified and as directed.

25

-

-

... More
All description as per srl item No 8 here- in- before but using cable size 1.5 Sqmm for 1 Nos 05 Amps Socket outlet independent with terminal boxes, Moduler fittings including acessories as moduler surface cover plate with frame, metal flush box,complete all as specified and as dierected.

25

-

-

... More
All as per srl item No 8 here- in- before but using cable size 2.5 Sqmm for 15 Amps Socket outlet terminal boxes for Modular switches including acessories as moduler surface cover plate with frame, metal flush box with 2.5 sqmm earth wire complete all as specified and as dierected.

20

-

-

... More
All as per srl item No 8 here- in- before but using cable size 4 Sqmm for 15 Amps Socket outlet terminal boxes for Modular switches including acessories as moduler surface cover plate with frame, metal flush box with 2.5 sqmm earth wire complete all as specified and as dierected.

20

-

-

... More
M&L for Point wiring with 1.5 Sqmm multistranded copper conductor cable multistranded, FRLSH PVC insulated and unsheathed in existing PVC casing & caping counduit including fixures and terminal boxes with all fittings /accessories and including 1.5 Sqmm PVC insulated copper earth wire connected common earth with terminal boxes for Modular fittings including acessories as modular surface cover plate with frame, for one light/Fan/Exhaust Fan/bell point complete all as specified and as directed.

20

-

-

... More
All description as per srl item No 12.00 here- in- before but using cable size 1.5 Sqmm for 1 Nos 05 Amps Socket outlet independent with terminal boxes, Moduler fittings including acessories as moduler surface cover plate with frame, metal flush box,complete all as specified and as dierected.

20

-

-

... More
S&F in replacement of Plug Top 16 Amps complete all as specified and as directed.

50

-

-

... More
S&F sheet metal enclosure with socket plug top and MCBs single pole and neutral 'C' curve enclosure with 2 pin and earth plug and socket complete with one single pole MCB 32 Amps 'C' curve complete.

20

-

-

... More
S&F modular switch 6 Amp single pole one way one module complete all as specified and as direcetd.

100

-

-

... More
S&F modular switch 16 Amp single pole one way one module complete all as specified and as directed.

100

-

-

... More
S&F modular socket outlet 6A-2/3Pin 2 Module complete all as specified and as direcetd.

100

-

-

... More
S&F modular socket outlet 6/16A-2/3 Pin 2 Module complete all as specified and as directed.

100

-

-

... More
S&F Fan step type regulator 120W - 2 module all as specified and as directed.

20

-

-

... More
S&F Fan step type regulator 1 module all as specified and as directed.

15

-

-

... More
M&L for Modular Bell push 6 Amp 1 Module complete all as specified and directed.

10

-

-

... More
M&L in replacement of Bell Ding Dong type AC 230Volts single Pole complete all as specified and directed.

10

-

-

... More
S&F in replacement of switch piano type flush type, single pole one way, 5 Amps

50

-

-

... More
S&F in replacement of socket outlet 2 in one, 3 Pin, 5 Amps

50

-

-

... More
S&F in replacement of switch piano type flush type, single pole one way, 15 Amps

50

-

-

... More
S&F in replacement of socket outlet 2 in one, 3 Pin, 5 & 15 Amps

50

-

-

... More
S&F in replacement of exhaust fan blade for siutable for 250/300 mm dia having 3/4 Blade for PVC body exhaust fan including connection and fixing on wall with nuts bolts washers etc complete.

20

-

-

... More
M&L in replacement of sub main wiring complete by using 4 run of 10 sqmm and two run of 10 sqmm PVC insulated unsheathed FRLSH multistranded copper conductor ISI marked 1100 V grade in existing concealed PVC conduit fixed in wall/floor,passing through wall/ceiling complete all as specified and directed. Note:- 6 Run of 10 Sqmm cable will be measured as one unit.

100

-

-

... More
M&L for in replacement of sub main wiring complete using 4 run of 6 sqmm and two run of 6 sqmm PVC insulated unsheathed FRLSH multistranded copper conductor ISI marked 1100 V grade in existing concealed PVC conduit fixed in wall/floor,passing through wall/ceiling complete all as specified and directed. Note:- 6 Run of 6 Sqmm cable will be measured as one unit.

100

-

-

... More
M&L for in replacement of sub main wiring 2x4.0 sqmm and 1x4 Sqmm earth wire PVC insulated FRLSH multistranded copper conductor ISI marked 1100 V grade in PVC concealed conduit or fixed in wall/floor,passing through wall/ceiling complete. Note:- 3 Run of 4 Sqmm and PVC conduit will be measured as one unit.

100

-

-

... More
M&L for in replacement of sub main wiring 2x6.0 sqmm and 1x6 Sqmm earth wire PVC insulated FRLSH multistranded copper conductor ISI marked 1100 V grade in existing PVC concealed conduit or fixed in wall/floor,passing through wall/ceiling complete. Note:- 3 Run of 6 Sqmm cable will be measured as one unit replacement.

100

-

-

... More
M&L for in replacment of sub main wiring 2x10 sqmm and 1x10 Sqmm earth wire PVC insulated FRLSH multistranded copper conductor ISI marked 1100 V grade in existing PVC conduit fixed in wall/floor,passing through wall/ceiling complete. Note:- 3 Run of 10 Sqmm cable will be measured as one unit.

100

-

-

... More
S&F ceiling rose of PVC/polycarbonate, isolated body three terminals complete all as dpecified and as direceted.

20

-

-

... More
S&F lamp holder angle /batten type PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.

20

-

-

... More
36. S&F in replacement energy efficient LED light fitting surface mounted 2' long, 10 watt, 240 volts, 50 hz made out of extruded aluminium housing with acrylic diffuser, LM 80 certified LED, costant current out put of electronic driver of operating voltage 140v to 270v and temperature - 10 digree centigrade to 50 digree centigrade with ingress protection IP 20 duly pre wired with insulated copper wire, PF0.95 with efficiency 120 lumins/watt and TDH less than 10%, CRI 90 digree , CCT 6500 K in and including connecting up with twin core copper flexible cable of suitable size upto ceiling rose complete all as specified and directed.

20

-

-

... More
S&F in replacement LED 9 watt circular shaped concealed light with white powder coated polycarbonate housing and pressure die cast heat sink having high efficiency complete incl connection with 1.5 Sqmm 3 core flexible copper cable complete all as specified and as directed.

20

-

-

... More
S&F in replacement LED 15 watt square LED panel with white powder coated polycarbonate housing and pressure die cast heat sink having high efficiency complete incl connection with 1.5 Sqmm 3 core flexible copper cable complete all as specified and as directed.

20

-

-

... More
S&F in replacement energy efficient LED light fitting surface mounted 4' long, 20 watt, 240 volts, 50 hz made out of extruded aluminium housing with acrylic diffuser, LM 80 certified LED, costant current out put of electronic driver of operating voltage 140v to 270v and temperature - 10 digree centigrade to 50 digree centigrade with ingress protection IP 20 duly pre wired with insulated copper wire, PF0.95 with efficiency 120 lumins/watt and TDH less than 10%, CRI 90 digree , CCT 6500 K in and including connecting up with twin core copper flexible cable of suitable size upto ceiling rose complete all as specified and directed.

500

-

-

... More
S&F in replecement energy efficient LED light fitting, slim LED panel, surface mounting 2 ft x 2 ft made out of power coated CRCA sheet with acrylic diffuser, constant current output of electronic driver operating voltage range of 150 to 270 volts AC, PF0.95, high powder LEDs having efficiency of 100-120 lumins/watts, junction temparature less than 85 digree C and TH less than 12 % and CCT 6500K,, CRT90 suitable for 36 watt LED, LM 80 certified LM, pri wired in and including connecting up with twin core copper flexible cable of suitable size upto ceiling rose /connector etc and testing complete all as specified and directed.

50

-

-

... More
S&F in replecement energy efficient LED light fitting, slim LED panel, recessed mounting 2 ft x 2 ft made out of power coated CRCA sheet with acrylic diffuser, constant current output of electronic driver operating voltage range of 150 to 270 volts AC, PF0.95, high powder LEDs having efficiency of 100-120 lumins/watts, junction temparature less than 85 digree C and TH less than 12 % and CCT 6500K,, CRT90 suitable for 36 watt LED, LM 80 certified LM, pri wired in and including connecting up with twin core copper flexible cable of suitable size upto ceiling rose /connector etc and testing complete all as specified and directed.

100

-

-

... More
S&F in replacement of LED bulb 7 Watt, B22 Base (3000 K) complete all as specified and as directed.

20

-

-

... More
S&F in replacement of LED bulb 9 Watt, B22 Base (6500 K) complete all as specified and as directed.

20

-

-

... More
S&F in replacement of extension cord 4x1, 5 Amps sockets with 4 mtr power cable including 5 Amps Plug Top complete.

2

-

-

... More
S&F in replacement of capacitor 2.5 Mfd including connection complete all as specified and as directed.

120

-

-

... More
M&L for MCB TPN distribution board suitable TPN, 8 Way, double door, 415 Volts complete all as specified and directed by Engr-in-Charge

5

-

-

... More
M&L for MCB TPN distribution board suitable TPN, 4 Way, double door 415 Volts complete all as specified and directed by Engr-in-Charge

5

-

-

... More
S&F sheet metal enclosure for DBs, 12 Way double door having 200 Amps rated bus bar 240 Volts AC complete

2

-

-

... More
S&F sheet metal enclosure for DBs, 8 Way, double door having 200 Amps rated bus bar 240 Volts AC complete

2

-

-

... More
Supply and fixing 63 A, 240V 10KA 'C' curve miniature circuit breaker (MCB) SPN of double pole in the DB complete with connection testing and commissioning complete all as specified and as directed.

50

-

-

... More
Supply and fixing 32 A, 240V 10KA 'C' curve miniature circuit breaker (MCB) SPN of double pole in the DB complete with connection testing and commissioning complete all as specified and as directed.

50

-

-

... More
S&F PVC conduit 25 mm dia medium grade including fittings/accessories, concealed in wall including cutting chasing and making good to disturb surfaces complete.

80

-

-

... More
S&F in replacement of Plug Top 6 Amps complete all as specified and as directed.

50

-

-

... More
S&F in replacement of heating element 1.5KW for 25 Ltr hot water heater complete including connection.

10

-

-

... More
S&F in replacement of inlet/outlet assembly to matching the existing 25/50 Ltr capacity geyser inclding fixing and testing complete.

10

-

-

... More
S&F in repalcement of thermostat switch for 25/50 Ltr geyser including LED indicator lamp complete

10

-

-

... More
S&F in replacement of LED tube rod 20 watt double side connection including side holder complete.

40

-

-

... More
S&F in replacenebt of PVC connection pipe, 600 mm long with brass Nut with rubber washer suitable for hot/cold water complete.

20

-

-

... More
S&F in replacement of modular cover plate with frame 1 module complete.

20

-

-

... More
S&F in replacement of modular cover plate with frame 2 module complete.

20

-

-

... More
S&F in replacement of modular cover plate with frame 3 module complete.

20

-

-

... More
S&F in replacement of modular cover plate with frame 4 module complete.

20

-

-

... More
S&F in replacement of modular cover plate with frame 6 module complete.

20

-

-

... More
S&F in replacement of modular cover plate with frame 8 module complete.

20

-

-

... More
S&F in replacement of PVC Sheathed copper cable 1.5 Sqmm 3 core complete.

80

-

-

... More
S&F in replacement of PVC Sheathed copper cable 2.5 Sqmm 3 core complete.

80

-

-

... More
Supply and fixing in replacement of MCB distribution board, double door, vertical type made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating, TPN 8 way. 415 volts with bus bar rating 200 Amps, dust and vermin proof and IP 43 - IK 09 protection suitable for incorporation of MCCB, including grouting in the wall, cutting & chasing etc complete all as specified.

1

-

-

... More
Material and Labour for earthing complete with copper earth plate electrode 60cmx60cmx3.15mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. Copper plate connected with copper strip of 20x3 mm by means of Copper nuts, bolts and washers. Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following:- a) Copper strip of size 20 mm x 3 mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover. (d) Angle iron frame made of 40x40x4 mm angle iron for 30x30 cm PCC pit for holding the pit cover. (e ) Apply two coat of synthetic enamel paint over one coat of red oxide zinc chrome primer on exposed steel surfaces and two coat of hot tar on embedded portion of steel surfaces.

5

-

-

... More
M&L in replacement Galvanised iron strip 25x4mm buried in ground including necessay excavation & earth work in soft/loose soil complete all as specified and directed.

200

-

-

... More
S&F in replacement GI Wire 4mm dia for connecting earthing complete.

200

-

-

... More
S&F in replacement hylam sheet of size 4"x4" including screw, washer etc complete all as specified and directed.

25

-

-

... More
S&F in replacement hylam sheet of size 6"x6" including screw, washer etc complete all as specified and directed.

20

-

-

... More
S&F in replacement hylam sheet of size 8"x8" including screw, washer etc complete all as specified and directed.

20

-

-

... More
Supply laying, testing and commissionnig of LT cable of size 16 Sqmm, 4 Core, 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimpimg type cable lugs in LT panel / MCCB in bldg etc to suit the cable laid in trenches/fixed to poles/drawn through pipes complete all as specified and directed.

150

-

-

... More
Supply,laying, testing and commissionnig of LT cable of size 25 Sqmm, 4 Core, 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimpimg type cable lugs in LT panel / MCCB in bldg etc to suit the cable laid in trenches/fixed to poles/drawn through pipes complete all as specified and directed.

50

-

-

... More
Supply,laying, testing and commissionnig of LT cable of size 50 Sqmm, 3.5 Core, 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimpimg type cable lugs in LT panel / MCCB in bldg etc to suit the cable laid in trenches/fixed to poles/drawn through pipes complete all as specified and directed.

150

-

-

... More
Supply and laying in replecement XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cable of size 95 Sqmm, 4 Core, (Heavy duty) with aluminium conductor, 11000 volts, grade complete all as specified and directed.

50

-

-

... More
Supply and laying in replecement XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cable of size 120 Sqmm, 3 Core, (Heavy duty) with aluminium conductor, 11000 volts grade cross sectional area 120 Sqmm 3 core complete.

150

-

-

... More
Supply and laying in replecement XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cable of size 150 Sqmm, 3 Core, (Heavy duty) with aluminium conductor, 11000 volts grade complete all as specified and directed.

50

-

-

... More
Supply,laying, testing and commissionnig of LT cables 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimpimg type cable lugs in LT panel / MCCB in bldg etc to suit the cable laid in trenches/fixed to poles/drawn through pipes complete of sizes 185 Sqmm 3.5 core.

150

-

-

... More
Supply,laying, testing and commissionnig of LT cable of size 240 Sqmm, 3.5 Core, 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimpimg type cable lugs in LT panel / MCCB in bldg etc to suit the cable laid in trenches/fixed to poles/drawn through pipes complete all as specified and directed.

100

-

-

... More
Supply,laying, testing and commissionnig of LT cable of size 300 Sqmm, 3.5 Core, 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimpimg type cable lugs in LT panel / MCCB in bldg etc to suit the cable laid in trenches/fixed to poles/drawn through pipes complete all as specified and directed.

150

-

-

... More
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables etc. and getting out in the following soil of strata complete all as specified and as directed.

-

-

-

... More
(a) Soft/Loose soil

135

-

-

... More
(b) Hard/ Dense soil

50

-

-

... More
(c) Soft/disintegrated Rock

20

-

-

... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed.

189

-

-

... More
Removal of excavated material [soil] to a distance not Exc 50m and depositing where directed at a level not exc 1.5m above the starting point where directed complete all as specified and as directed.

21

-

-

... More
M&L for Servicing of the window AC 1.5 ton capacity of any make, including oiling/greasing the blower motor, cleaning the evaporator condenser coils externally to remove the dust, reassembling and re-fixing the air conditioner at its original position or complete all as specified and directed.

25

-

-

... More
All as per item Ser No.86 above but for split type AC (Inverter type) 1.5 ton capacity (Inner & Outer unit) complete all as specified and directed.

50

-

-

... More
All as per item Ser No.86 above but for split type AC 2.0 ton capacity (Inner & Outer unit) complete all as specified and directed.

30

-

-

... More
All as per item Ser No. 86 above but for split type AC 3.0 ton capacity (Inner & Outer unit) complete all as specified and directed.

8

-

-

... More
M&L for in rewinding of Fan Motor/blower motor of AC (Window/ Split Type) 1.5/2.0/3.0 TR Capacity complete all as specified and directed.

20

-

-

... More
M&L for in replacement Fan Motor of AC (Window/ Split Type) 1.5 TR Capacity complete all as specified and directed.

50

-

-

... More
All as per item Ser No 91 above but AC (Window/Split Type) 2.0 TR Capacity.

20

-

-

... More
All as per item Ser No 91 above but AC (Window/Split Type) 3.0 TR Capacity.

20

-

-

... More
S&F cooling coil suitable for Split type room AC 1.5 TR including taking out unserviceable cooling coil complete all as specified and directed.

20

-

-

... More
S&F Condensing coil suitable for Split type AC 1.5 TR including taking out unserviceable condensing coil complete all as specified and directed.

20

-

-

... More
S&F cooling coil suitable for Split type room AC 2.0 TR including taking out unserviceable cooling coil complete all as specified and directed.

20

-

-

... More
S&F Condensing coil suitable for Split type AC 2.0 TR including taking out unserviceable condensing coil complete all as specified and directed.

30

-

-

... More
S&F cooling coil suitable for split type AC 3 TR capacity including taking out unserviceable cooling coil complete all as specified and directed.

8

-

-

... More
S&F Condensing coil suitable for split type AC 3 TR capacity including taking out unserviceable condensing coil complete all as specified and directed.

8

-

-

... More
Suuply & Fix in replacement of Hermitacally sealed compressor for split type AC capacity 1.5 Ton complete all as specified and directed.

20

-

-

... More
Suuply & Fix in replacement of Hermitacally sealed compressor for split type AC capacity 2.0 Ton complete all as specified and directed.

15

-

-

... More
Suuply & Fix in replacement of Hermitacally sealed compressor for split type AC capacity 3.0 Ton complete all as specified and directed.

8

-

-

... More
S&F in replacement PCB with remote for window type AC of 1.5 Ton capacity complete all as specified and directed.

15

-

-

... More
S&F in replacement PCB with remote for Split type AC of 1.5 Ton capacity complete all as specified and directed.

25

-

-

... More
S&F in replacement PCB with remote for Split type AC of 2.0 Ton capacity complete all as specified and directed.

20

-

-

... More
S&F in replacement PCB with remote for Split type AC of 3.0 Ton capacity complete all as specified and directed.

8

-

-

... More
M&L in repair of PCB for Split/window AC of 1.5/2.0/3.0 Ton capacity complete all as specified and directed.

50

-

-

... More
Supply and charging the gas refrigerant R22 of window/split type AC upto 3 ton capacity including testing after application of nitrogen gas pressure to find out any leakage, brazing and stopping of all leakage detected, re-application of nitorgen pressure to ensure leak proof gas circulator system flushing out the nitrogen gas complete all as specified and directed.

50

-

-

... More
All as per item Ser No 108 above but R- 410 for split type AC up to 3 TR capacity.

50

-

-

... More
All as per item Ser No 108 above but R-32 Refg upto 03 Ton AC.

50

-

-

... More
S&F in replacement of electrolyte grade copper tubing of size 1/4" suitable for any type of split type AC including synthetic rubber foam complete all as specified and directed. Note: - The quoted rate is inclusive of necessary T&P, Rope, Ladder etc with safety equipment for execution the work for multy story building.

50

-

-

... More
All as per item Ser No.111.00 above but size 1/2".

50

-

-

... More
All as per item Ser No.111.00 above but size 3/8".

50

-

-

... More
All as per item Ser No.111.00 but size 5/8".

50

-

-

... More
M&L in replacement Capacitor Running 36 mfd – 45 mfd suitable for new/star rated for AC (Window/Split Type) 1.5 TR/2.0 TR Capacity and of any make complete all as specified and as directed.

50

-

-

... More
M&L in replacement Capacitor Starting 80 mfd – 120 mfd suitable for old ones AC (Window/Split Type) 1.5 TR/2.0 TR Capacity and of any make complete all as specified and as directed.

50

-

-

... More
M&L in replacement Fan Motor Capacitor 4 mfd of suitable for new/star rated AC (Window/Split Type) 1.5/2.0TR capacity complete all as specified and as directed.

80

-

-

... More
M&L for laying reinforced concrete pipes for cable protection, class NP-2 of dia 100 mm, 2 nos half round (for bottom and top) and before laying exacaved area shall be leveling all as specified and directed.

50

-

-

... More
M & L for Earthing complete (Generator, Transformer, lightning arrestor and feeder pillar box) with galvanised steel earth plate electrode '60cm × 60cm × 6mm thick, buried 'directly in ground (earth pit not less 'than 2.5 metres deep below normal ground 'level) with top edge of the plate not 'less than 1.5 metres below normal ground level', connected to 'galvanised iron strip 32x6mm by means of bolts, nuts, check 'nuts and washers of galvanised iron or steel earth strip protected by provision of GI 'medium grade' pipe 40mm bore including provision of concrete pit in PCC (1:2:4) type B1 (using 20mm graded stone aggregate) with 40mm thick cover in RCC (1:2:4) type B-1 reinforced with XPM (weight not less than 4 kg/sqm) and frame made out in MS angle iron of size 25x25x3mm with lugs 02 Nos and with MS handle made in 6mm dia round bar made to shape, including GI 'medium grade' 20mm bore pipe for watering, perforated at bottom 1.75m long placed on top edge of earth plate including including provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate, test point made out of ohosphorus bronze with fixing arrangement ,funnel, wire mesh and earth work in hard/dense soil returning filling in and removal of surplus soil to a distance not exceeding 50mtr all as shown in electrical plate No. 5 of SSR Part I 2009 connected to earthing test point all as specified or indicated 'including testing on completion.NOTE:-GI strip and GI pipe 40mm bore medium grade for encasing GI strip upto 7.50m length per earthing shall be deemed to be included in the unit rate.

7

-

-

... More
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required for 32x6 galvanized iron strip, complete all as specified and directed.

50

-

-

... More
Supply and laying in trenches burnt brick sub class 'B', standard size in trenches for cable protection keeping width of the brick parallel to the length of the cable all as specified and directed.

3

-

-

... More
Supply ad laying un-reinforced factory made precast concrete cable cover, class HV, type 1, flat size-300x180x40 mm complete all as specified and directed.

100

-

-

... More
Supply and spread clean and dry river sand in trenches ,ducts including leveling, punning for cushioning of cables all as specified Note : Punned thickness of sand cushioning shall be measured.

15

-

-

... More
S&F in replacement MCCB 630 Amps, 'C' curve, 4 Pole breaking capacity 50 KA microprocessor based (ICS=100% of ICU) with rotary handle complete all as specified and directed.

1

-

-

... More
S&F in replacement MCCB 400 Amps, 'C' curve, 4 Pole breaking capacity 50 KA microprocessor based (ICS=100% of ICU) with rotary handle complete all as specified and directed.

1

-

-

... More
S&F in replacement MCCB 250 Amps 4 Pole breaking capacity 50 KA microprocessor based (ICS=100% of ICU) with rotary handle complete all as specified and directed.

1

-

-

... More
S&F in replacement MCCB 160 Amps, 'C' curve, 4 Pole breaking capacity 25 KA thermal magnetic release (ICS=100% of ICU) complete all as specified and directed.

1

-

-

... More
S&F in replacement MCCB 125 Amps, 'C' curve, 3 Pole breaking capacity 25 KA fixed type (ICS=100% of ICU) complete all as specified and directed.

1

-

-

... More
S&F in repair MCCB 63/100Amps, 'C' curve, 3 Pole breaking capacity 16KA thermal magnetic release ((ICS=100% of ICU) complete all as specified and directed.

2

-

-

... More
S&F in repair jointing kit for 11 kv ( earthed) grade cable indoor type for end termination, heat shrinkable of size 50 to 95 sq mm, 3 core conforming to IS - 7098 part-II including thimblling, nut/bolts & washers, HV insulating tape etc, complete all as specified and directed.

3

-

-

... More
S&F in repair jointing kit for 11 kv ( earthed) grade cable indoor type for end termination, heat shrinkable of size 120 to 185 sq mm, 3 core conforming to IS - 7098 part-II including thimblling, nut/bolts & washers, HV insulating tape etc, complete all as specified and directed.

3

-

-

... More
S&F in repair straight through joint 11 kv heat shrinkable of size upto 95 sq mm, 3 core conforming to IS - 7098 part-II including thimbling, nut/bolts & washers, HV insulating tape etc, complete all as specified and directed.

1

-

-

... More
S&F in repair straight through joint 11 kv heat shrinkable of size 120 to 185 sq mm, 3 core conforming to IS - 7098 part-II including thimbling, nut/bolts & washers, HV insulating tape etc, complete all as specified and directed.

2

-

-

... More
Supply and laying in replecement XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 150 Sqmm 3 core complete.

100

-

-

... More
M&L for PCC 1:3:6 type C-1 (using 20 mm graded stone aggregates) for repairing foundation of LT pole/ panel etc including filling in road cuts/hard standing etc complete all as specified and directed.

3

-

-

... More
M&L for PCC 1:4:8 type D-1 (using 20 mm graded stone aggregates) for repairing of LT pole/ panel foundation etc including filling in road cuts/hard standing etc complete all as specified and directed.

1.2

-

-

... More
Supply,laying, testing and commissionnig of LT cable of size 400 Sqmm , 3.5 core, 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimpimg type cable lugs in LT panel / MCCB in bldg etc to suit the cable laid in trenches/fixed to poles/drawn through pipes complete all as specified and directed.

50

-

-

... More
Supply and laying 80mm bore light grade GI pipe fixed to walls / poles or laid in trenches, road crossing etc, for protection of under ground cable including sealing ends with hessian cloth impregnated with bituminous compound in ground and with suitable clamps, bolt/nuts etc for fixing on walls, poles etc. complete all as specified and directed.

20

-

-

... More
Supply and laying 50mm bore light grade GI pipe fixed to walls / poles or laid in trenches, road crossing etc, for protection of under ground cable including sealing ends with hessian cloth impregnated with bituminous compound in ground and with suitable clamps, bolt/nuts etc for fixing on walls, poles etc. complete all as specified and directed.

20

-

-

... More
Supplying and laying synthetic rubber insulated mats 3 mm thick for voltage upto 33 KV (size 2 m x 1 mtr) for electrical purpose as per IS 15652-2006 suitable for electrical shock safety complete all as directed.

3

-

-

... More
Maintenance /servicing / Repair to 250 KVA Compact Sub Station includes HT sides, LT sides and connected switchgears / spares parts etc complete will be carried out by OEM only including replacement of unserviceable parts by new parts as per part list of OEM as specified and directed. Note : - 1. Spares required for above maintenance / repair deemed to be included in this item only and Servicing to be carried out as per manufacturer instruction.

2

-

-

... More
Dehydration and Filteration of 11 KV grade Transformer oil through stream line filteration plant for extracting moisture content in the oil and carbon deposits and achiving the dielectric strength to 40 KV for 1 minute with a sphare gap of 2.5 mm and also checking the acidity of oil with acidity test kit and submitting the necessary test kit report /certificate, refilling the filtered oil into any KVA transformer etc as specified and directed. Note: The filtration includes taking necessary connection to filtration plant from the transformer to their hose pipe by opening the inlet and outlet of transformers and closing the same after filtration.

1500

-

-

... More
Taking out HT VCB/OCB ,11 KV grade 400 Amps rating from HT panel for servicing / repairs by dismantling the HT VCB operating mechamism, inspection of control wiring realignment of moving contacts with fixed contacts assy, vaccum interrupter ,checking of relays for protection, greasing of all moving parts of mechanis, checking and realignment of mechanism for its proper functioning and operation, re-assembling of HT VCB , fixed in its original position , testing for functions, and commissioning complete all as directed by Engr in charge.

10

-

-

... More
Supply and fixing of push button suitable for 400 amps VCB/OCB complete all as specified and directed.

5

-

-

... More
Supply and fix in repair HT bushing spout of fibre or as per existing for 11 KV HT VCB 400 Amp rating complete all as directed by Engr in charge.

9

-

-

... More
Calibration of 11 KV grade HT VCB /OCB relays of various types / Make by OEM through primary & Secondary injection method by bringing relay test kit, software PC system and other required measuring equipments to the site, after testing refixing to VCB/OCB 11 KV panel all as directed by Engr-in-Charge. Note- Certificate of this test will be provided by the contractor free of cost.

13

-

-

... More
Testing of HT current transformer (set of three) through primary current injection method and also checking the connected panel wiring by brining required test kit and other required testing equipment and also checking tripping and closing operation complete all as directed by Engr-in-Charge.

5

-

-

... More
Supply, install, test, commissioning of 11 KV grade HT VCB/OCB current transformer in repair CT of 11 KV grade with CT ratio 300/150/5-5 fixed with HT VCB 11 KV including necessary cable connection etc suitable for fixing in HT panel board of any make including modification required at site to be carried to fix CT upto recess/coils including removing the burnt CTs complete all as directed.

5

-

-

... More
M & L for checking of Potential Transformer by conducting ratio test/meggering for IR values, provided in VCBs/OCBs 11 KV feeders checking of control wiring meters, relay and tripping system complete all as directed by Engr-in-Charge.

2

-

-

... More
S & F in repair Potential Transformer for HT OCB/VCB 11/110 volts/3, 100 VA resincast appoxy moulded with metal enclosure as per site requirement and connecting bus bar including providing bus bar, testing for functionality complete all as directed by Engr-in-Charge.

1

-

-

... More
Supply and fixing HT Voltmeter, range 0 to 15 KV auxillary supply 110 Volts suitable for fixing with existing HT VCB 11 KV panel.complete all as directed by Engr-in-Charge.

2

-

-

... More
Supply and fixing ammeter suitable for fixing with existing HT VCB / OCB 11 KV panel ratio like 300/5,200/5,100/5 complete all as directed by Engr-in-Charge.

2

-

-

... More
Supply only hand gloves HT for operating / handling sub station upto 22 KV ISI Marked.complete all as directed.

2

-

-

... More
Supply and fix in repair breather assembly suitable for existing transformer upto 500 KVA capacity complete all as specified and directed.

2

-

-

... More
Repair to transformer to arrest oil leakage by removing transformer oil , dismantling the top cover alongwith conservator tank/ OLTC, replacing the top gasket washer etc replacement of HT/LT bushes complete dismantling the cooling fins and welding where leakage to arrest oil leakage and reassembling the transformer, refilling filtered oil testing complete for transformer capacity upto 500 KVA all as directed. Note- Filteration of oil and all other spares/ Material will be measured and paid separately .

1

-

-

... More
Dismantalling the exsisting Transformer upto 500 KVA transformer by disconnecting incoming and outgoing HT/LT cables/bus duct connection, shifting to workshop by arranging suitable vehicle and crane and removing tank top cover /lid of 11 KV grade at workshop , draining out the transformer oil and keeping in safe custody in clean and dry containers for reuse and carrying out the maintenance work by experienced and qualified Engineer , dismantling the OLTC/ conservator tank , dismantling HT/LT bushings from core winding and lifting the core assy carefully without damaging by using the tripod/ chainpully/crane etc, cleaning / removing the sludge from the transformer tank, cleaning the OLTC/ conservator tank and checking the serviceability of the coil / core winding , checking the condition of the body , cleaning the coil/ core assy , refixing of core , core assy , OLTC/ conservator tank, HT/LT winding connection, connection of protective devices like buckholz relay connection,winding temperature indication ,oil temperature indication including fixing new gaskets to transformer top and all other places gaskets/washer , terminal studs of HT/LT sides and reassembling of transformer after repairs, refitting the transformer coil incl improvement of insulation resistance value within desired level by heating or any other method to required level and re assembling at the site, connection of LT/HT sides, testing and charging the transformer complete all as directed to the entire satisfaction of Engr in Charge. Note- Filteration of oil and all other spares/ Material will be measured and paid separately .

2

-

-

... More
Supply only silica gel in the transformer breather assy including taking out UNSV silicagel complete.

2

-

-

... More
Supply only HV Bushing suitable for upto 500 KVA transformer including connection complete all as directed.

2

-

-

... More
Supply only LV Bushing suitable for upto 500 KVA transformer including connection complete all as directed.

2

-

-

... More
Supply only copper terminal stud , both end threaded complete with double nuts and washers with heat resistant gasket suitable for upto 500 KVA transformer LV side 415 volts including connection complete all as directed.

2

-

-

... More
Supply and fill transformer oil duly filtered and tested confirming to IS 335 1963 as amended including all testing complete all as directed.

300

-

-

... More
Supply only (HV side) copper winded coil of existing type size and guage 11000 volts complete with insulating material for trnsformers of upto 500 KVA complete all as directed.

150

-

-

... More
All as per Item No 162.00 above but LT side, 415 volts grade complete all as directed.

150

-

-

... More
Supply and fixing of limit switch suitable for 400 amps VCB/OCB complete all as specified and directed.

2

-

-

... More
Supply and fixing of AC/DC controling unit suitable for 400 amps VCB/OCB complete all as specified and directed.

2

-

-

... More
Supply and fixing of Triping and closing coil 24 v DC suitable for 400 amps VCB/OCB complete all as specified and directed.

2

-

-

... More
Supply and fixing of bushing suitable for 400 amps VCB/OCB complete all as specified and directed.

3

-

-

... More
Supply and fixing of bushing rod suitable for 400 amps VCB/OCB complete all as specified and directed.

3

-

-

... More
Supply and fixing of CT with ratio 100/50/5+1 suitable for 400 amps VCB/OCB complete all as specified and directed.

3

-

-

... More
Supply and fixing of 11 kv OCB spout contact suitable for 400 amps VCB/OCB complete all as specified and directed.

9

-

-

... More
Supply and fixing of panel wiring complete suitable for 400 amps VCB/OCB complete all as specified and directed.

1

-

-

... More
Supply and fixing of earth fault over current relay IDMT relay suitable for 400 amps VCB/OCB complete all as specified and directed.

2

-

-

... More
Supply and fixing of 5 way RMU CT 400/200/1-1 complete suitable for RMU complete all as specified and directed.

3

-

-

... More
Taking proper shutdown & Isolate the HT electric supply and HT 11KV outdoor upto 5 way RMU of any make and type and servicing of all minor/major parts of the RMU by cleaning isolating contact moving parts,removing dust particle from the bus bar chamber spout gear mechanism, repair to motor charge spring mechanism,tightening of all nut & bolts and testing the complete HT electric supply and putting on supply on load complete all as directed.

4

-

-

... More
S&F in replacement of HRC/MCB fuse link clip type on fuse link 2 to 20 amps operating voltage 415 Volt complete all as specified and directed.

2

-

-

... More
S&F in replacement of fuse base suitable for cylindrical/DIN type HRC fuse of capacity 2-32 amps complete all specified and directed.

2

-

-

... More
S&F in replacement of closing spring assembly complete all as specified and directed.

2

-

-

... More
S&F in replacement of tripping spring assembly complete all as specified and directed.

2

-

-

... More
S&F in replacement of charging motor cut off limit switch complete all as specified and directed.

2

-

-

... More
S&F in replacement of spring charging handle motorized mechanism of VCB complete all as specified and directed.

2

-

-

... More
S&F in replacement of push button bracket assembly complete all as specified and directed.

1

-

-

... More
S&F in replacement of bus bar support insulator 75 mm dia including all fixing accessories complete suitable or VCB/HT bus bar chamber all as specified and directed.

2

-

-

... More
S&F in replacement of bus bar barrier as per existing (set of three) with nuts bolts complete all as specified and directed.

2

-

-

... More
S&F in replacement of toggle switch for space heater complete with all accessories all as specified and directed.

2

-

-

... More
S&F in replacement of charged/ discharged indication assembly complete all as specified and directed.

2

-

-

... More
S&F in replacement of 11 pin anti pumping relay 110 volt DC complete all as specified and directed.

3

-

-

... More
S&F in replacement of bottom terminal with jaw contact complete all as specified and directed.

1

-

-

... More
S&F in replacement of top terminal with jaw contact complete all as specified and directed.

1

-

-

... More
S&F in replacement of PT epoxy female bushing suitale for R Y B phase complete all as specified and directed.

1

-

-

... More
S&F in replacement of PT epoxy male bushing suitale for R Y B phase complete all as specified and directed.

1

-

-

... More
S&F in replacement of PT fuse 11 KV complete all as specified and directed.

1

-

-

... More
S&F in repair HT bushing 11 kv suitable for upto 500 KVA transformer including brass rod complete with gasket as per matching to existing all as specified and directed.

2

-

-

... More
S&F in repair LT bushing 11 kv suitable for upto 500 KVA transformer including brass rod complete with gasket as per matching to existing all as specified and directed.

2

-

-

... More
S&F in repair head gasket sheet 6 mm thick suitable for transformer upto 500 KVA capacity including replacement of nuts bolts washers including necessary T&P required at site complete all as specified and directed.

2

-

-

... More
S&F in repair temparature gauge analog type complete with all accessories as per matching to existing complete all as specified and directed.

1

-

-

... More
S&F in repair three phase over current earth fault relay MC-61 as per matching to existing one including all accessories and wiring complete all as specified and directed.

1

-

-

... More
S&F in repair three phase over current earth fault relay MC-61A as per matching to existing one including all accessories and wiring complete all as specified and directed.

1

-

-

... More
S&F in repair Led type indication lamp of voltage AC/DC set of RYB as per matching to existing complete all as specified and directed.

5

-

-

... More
S&F in repair battery charger of capacity 12 volts for AMF panel complete all as specified and directed.

1

-

-

... More
S&F in repair battery charger of capacity 24 volts for AMF panel complete all as specified and directed.

1

-

-

... More
S&F in repair HT three phase digital multifunctional meter suitable for measure all electrical quanlities like voltmeter, current, power, Frequency & power factor complete all as specified and directed.

3

-

-

... More
S&F in repair LT three phase digital multifunctional meter suitable for measure all electricl qualities like voltmeter, current, power, Frequency & power factor complete all as specified and directed.

5

-

-

... More
S&F in repair VCB power pack unit 24 volt DC 7 AH with battery bank for backup for panel as per existing matching complete all as specified and directed.

1

-

-

... More
Supply and fixing in replacement of RMU protection relay model No- CSDPR-V2 type CSDR-V2-300-D-L-P, Frequence-50Hz, UN-in-1A, UV-18-60 volt DC and control rating-5A @ 220 volt AC and making as per existing make (C&S) with all connected accessories complete all as specified.

1

-

-

... More
M&L for painting of LT panel indoor/outdoor type area of front face of panel exc 1.5 Sqm but n. exc 2.5 sq m each with spray gun with two coats of synthetic enamel heat resistant grey paint including preparation of old painted surface/ removing old faded/rust/cemeted material of surface of complete LT panel complete all as specified and directed.

4

-

-

... More
S&F in repair old unserviceable angle iron work and fixing/fabrication of angle iron frame 40x40x5 mm thick for LT panel complete including welding work at site complete all as specified and directed.

60

-

-

... More
S&F in repair LT panel of any size/make incl cutting, welding of front panel back cover and top cover made of CRCA steel sheet of size not less than 3.15 mm thick as per site requirement including colour matching with existing including hinges and locking device complete all as specified and directed.

5

-

-

... More
S&F in repair of alluminium bus bar PVC insulated in red,yellow, blue & black colours of rating 400 amps complete all as specified and directed.

25

-

-

... More
S&F in repair of alluminium bus bar PVC insulated in red,yellow, blue & black colours of rating 800 amps complete all as specified and directed.

25

-

-

... More
S&F in repair of alluminium bus bar PVC insulated in red,yellow, blue & black colours of rating 1500 amps complete all as specified and directed.

30

-

-

... More
S&F in repair of APFC relay for upto 225 KVAR 10 stages including wiring CTs and all connected item complete all as specified and directed.

2

-

-

... More
S&F in repair of LED type indicating lamp type of voltage AC/DC set of RYB as per matching to existing complete all as specified and directed.

4

-

-

... More
S&F in repair of capacitor bank MP-05 KVAR capacity rated 440 volts AC, 3 phase, 50 Hz delta connection round type complete all as specified and directed.

2

-

-

... More
S&F in repair of capacitor bank MP-10 KVAR capacity rated 440 volts AC, 3 phase, 50 Hz delta connection round type complete all as specified and directed.

2

-

-

... More
Servicing /Caliberation / Repairs to Air Circuit Breaker 800 to 1600 Amps by OEM of ACB only for EDO ( Electrically Draw Out) type/ MDO type(Mannually Draw out type)/ Fixed type. Taking out any type of ACB for servicing / repair and checking / caliberation of microprocessor release,Earth fault protection of 4 pole, 50 KA breaking capacity 415 volts with all draw out type mechanism, advanced self powered electronic protection units, neutral overload protection, automatic earth fault relay / over current relay , automatic safety shutter, inbuilt temperature protection, icu=ics=icw(1s)=50 KA fixed in panel complete including relay wiring checking ,LT UG cable connection with main incoming ACB complete connection for its healthy functioning all as directed. Note- Certificate of Servicing /Caliberation will be provided by the contractor free of cost.

6

-

-

... More
Supply & fix in repair protection releases for air circuit breakers microprocessor based type suitable for existing breakers as per site make / requirement including taking out breakers after taking shutdown of electric supply complete all as specified and directed.

1

-

-

... More
Supply & fix in repair earth fault realease for air circuit breakers microprocessor based type suitable for existing breakers as per site make / requirement including taking out breakers after taking shutdown of electric supply complete all as specified and directed.

2

-

-

... More
Supply & fix in repair shunt realease for air circuit breakers microprocessor based type suitable for existing breakers as per site make / requirement including taking out breakers after taking shutdown of electric supply complete all as specified and directed.

1

-

-

... More
Supply & fix in repair under voltage realease for air circuit breakers microprocessor based type suitable for existing breakers as per site make / requirement after taking shutdown of electric supply complete all as specified and directed.

1

-

-

... More
Supply & fix in repair lockable trip push button for air circuit breakers microprocessor based type suitable for existing breakers as per site make / requirement after taking shutdown of electric supply complete all as specified and as directed by Engr-in-Charge.(Make- L&T-8301 or equivalent in Legrand/ABB/Schenider).

1

-

-

... More
M&L for bringing Cable testing van (Fault Finder) for detecting the location of fault in the LT UG cable 1.1 KV and HT UG cable 11 KV grade of any size complete all as specified and as directed

20

-

-

... More
M&L in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 120 to 400 Sqmm 3.5 core including all accessories required complete all as specified and as directed.

5

-

-

... More
M&L in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 50 to 95 Sqmm 3.5 core including all accessories required complete all as specified and as directed.

5

-

-

... More
M&L in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 16 to 35 Sqmm 3.5 core including all accessories required complete all as specified and as directed.

5

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.