Jawaharlal Nehru University Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Jawaharlal Nehru University - JNU Tender
Eprocure
Opening Date8 May 2019
Closing Date20 May 2019
Tender Amount₹ 16,26,991
Costs
EMD
₹ 32,540Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_JNU_468170_1Bid Award Id
ViewTender No
NIT No. JNU/Engg./04/2019-20Tender Authority
Jawaharlal Nehru University ViewPurchaser Address
-Website
http://https://www.jnu.ac.in/main/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
general condition of contract
BOQ Items
Rewiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel conduit including dismantling as required.
-
-
-
Group B
350
-
-
Rewiring for twin control light point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel conduit including dismantling as required.
48
-
-
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required.
-
-
-
2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire
200
-
-
2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire
200
-
-
2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire
600
-
-
4 x 2.5 sq.mm. + 2 x 2.5 sq.mm. earth wire
150
-
-
4 x 4 sq.mm. + 2 x 4 sq.mm. earth wire
500
-
-
2 x 10 sq.mm. + 1 x 6 sq.mm. earth wire
50
-
-
4 x 16 sq.mm. + 2 x 6 sq.mm. earth wire
25
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required.
-
-
-
1 x 1.5 sqmm.
150
-
-
3 x 1.5 sqmm.
1200
-
-
3 x 2.5 sqmm.
600
-
-
6 x 2.5 sqmm.
200
-
-
3 x 4 sqmm.
500
-
-
6 x 4 sqmm.
200
-
-
Supply and drawing following pair 0.5 sq.mm. FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/recessed steel/ PVC conduit as required.
-
-
-
2 Pair
100
-
-
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
-
-
-
20 mm
100
-
-
25 mm
100
-
-
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. .
-
-
-
250 mm X 300mmX100mm deep
10
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
-
-
-
5/6 amps switch
400
-
-
2 way 5/6 amps switch
96
-
-
3 pin 5/6 amps socket outlet
70
-
-
Telephone socket outlet
17
-
-
Bell Push
14
-
-
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
70
-
-
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
100
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
-
-
-
1 or 2 Module (75mmX75mm)
134
-
-
3 Module (100 mmX75 mm)
50
-
-
4 Module (125mmX75mm)
50
-
-
6 Module (200mmX75mm)
30
-
-
8 Module (125mmX125mm)
60
-
-
12 Module (200mmX150mm)
40
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modularswitch, connection etc. as required. (For light plugs to be used in non residential buildings).
65
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
104
-
-
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/wooden block incuding connectin etc as reuqired.
100
-
-
Supplying andf fixing brass batten/angle holder including connection etc as required.
183
-
-
Erection of wall bracket/ceiling fittings of all sizes and shapes containing upto two GLS lamps per fitting, complete with all accessories including connection etc. as required.
64
-
-
supplying andf fixng call bell/buzzer suitable for single phase,230 volts, complete as required.
28
-
-
installation, testing and commissioning of pre-wired, fluorescent accessories and tube etc directly on ciling/wall, including connection with 1.5 sq.mm. FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
60
-
-
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm. FRLS PVC insulated, copper conductor, single core cable etc as required.
70
-
-
Numbering of ceiling fan/exhaust fan/fluorescent fittings as required.
130
-
-
Installation of exhaust fan in the existing opening, including making good the, damage, connection, testing, commissionining etc as required.
-
-
-
upto 450 mm sweep
10
-
-
Extra for fixing the louvers / shutters complete with frame for exhaust fans of all sizes.
10
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/recess, compelte with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
-
-
-
16 way, Double door
3
-
-
Supplying and fixing following way, horizontal type three pole and enutral, sheet stee, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc as required. (But without MCB/RCCB/Isolator)
-
-
-
8 way (4 + 24), Double door
7
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required.
-
-
-
Single pole
210
-
-
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc as required.
-
-
-
63 amps
3
-
-
Supplying and fixing following rating, 4 pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc as required.
-
-
-
63 amps
7
-
-
Supplying and fixing 20 amps, 240 volts, SPN industrial type,socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket on surface or in recess, with chained metal cover for the socket on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
43
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
-
-
-
upto 35 sq.mm.
50
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
-
-
-
upto 35 sq.mm. (clamped with 1 mm thick saddle)
50
-
-
Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
-
-
-
4 x 25 sq.mm. (28mm)
10
-
-
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/ submain wiring/cable as required.
200
-
-
Supply of 1100 volts rated aluminium conductor steel wire / strip armored XLPE power cable of following sizes as per IS-7098 part-I with ISI marked including testing at manufacturer site etc complete as required.
-
-
-
4 Core 25 sq. mm. Armoured Aluminium cable.
100
-
-
SITC of metering cubical panel made of 14 SWG CRCA sheet complete with 100A, 4 strip aluminium bus bar including providing and fixing 10-60A 3 Phase electronics energy meter in poly carbonate body with counter display of class-I accuracy, 1 No 63A, TP MCB connection, inter connection hinged cove in front painting sing working etc as required.
3
-
-
Supply of 1x40 watt box type luminair made of powder coated CRCA sheet steel enclosure with decorative end caps ,1x36W electronic ballast, tube holder including testing as required.
60
-
-
Supply of copper wound heavy duty Electrical Exhaust fan of sweep 300 mm, having running speed of 900 RPM suitable to operate on 230 V , 50 Hz, A.C supply along with Louvers, of suitable size, nut bolts etc complere as required.
10
-
-
Supply of wall mounted decorative light fixture made up of Polycarbonate, suitable for 15 W retrofit CFL as per Havells Cat. No-LHDL06160099 or equivalent approved make complete in all respects.
64
-
-
Dismantling of existing old fittings/switch board such as wall bracket light/ tube light fitting/ Switch board / 5 Amp switch socket/ 15 A switch socket DB,s,replacing of M.S boxes etc at site and storing at site/ transporting to the store including making good the demage with cement, sand as required.
-
-
-
For type-Iv Qtrs
3
-
-
For type-v Qtrs
4
-
-
For Type-Vi Qtrs
3
-
-