Jawaharlal Nehru University Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Jawaharlal Nehru University - JNU Tender
Eprocure
Opening Date18 Jan 2019
Closing Date28 Jan 2019
Tender Amount₹ 16,16,227
Costs
EMD
₹ 32,325Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_JNU_432453_1Bid Award Id
ViewTender No
NIT No. JNU/Engg./28/2018-19Tender Authority
Jawaharlal Nehru University ViewPurchaser Address
-Website
http://https://www.jnu.ac.in/main/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
general condition of contract
BOQ Items
Panel No 1. (for A.C & Non-A.C Panel Near Sanskrit Centre)
i) Incomming: – • 400 amp 3 pole, 35kA, MCCB with adjustable thermal & adjustable magnetic setting i/c Ics=100% of Icu --- 1 No ii) Bus Bar:- 600 Amps, 4 strip aluminium conductor iii) Outgoing:- • 200 amp 3 pole, 35kA Fixed Thermal & fixed magnetic setting MCCB Ics=100% of Icu --- 3 Nos. • 100 amp 3 pole, 35kA Fixed Thermal & fixed magnetic setting MCCB Ics=100% of Icu --- 3 Nos.
• 3 phase ...Indicating lights, 0-500 V digital Voltmeter, 0-500 Amp Ammeter3 Nos C.T's, selector switch.
2
-
-
Panel No 2:- (for A.C Panel outside Sanskrit centre)
i) Incomming: – •200 amp 3 pole, 35kA, Fixed Thermal & fixed magnetic setting MCCB of Ics=100% of Icu --- 1 No
ii) Bus Bar:- 400 Amps, 4 strip aluminium conductor
iii) Outgoing:- • 100 amp 3 pole, 25kA, Fixed Thermal & fixed magnetic setting MCCB of Ics=100% of Icu --- 6Nos.
• 3 phase ...Indicating lights, 0-500 V digital Voltmeter, 0-500 Amp Ammeter3 Nos C.T's, selector switch.
2
-
-
Fabrication, supply, installation, testing and commissioning of electrical power distribution cubical panel board Indoor type fully compartmentalized complete with base frame, vermin and dust proof design, neoprene gasket with suitable M.S top cover,2 No’s G.I Bus Bar for earth connection 50mm X 5mm size, entirely fabricated from at least 2 mm thick CRCA sheet steel ,duly treated for preventing corrosion , passivised and powder coated in approved colour, with depth of 400mm, complete with masonry foundation blocks duly finished with cement sand plaster, PVC insulated copper wiring for inter connection as applicable and following switchgears supply fixing following switchgears mounted thereon, earthing, sign writing etc as required:-
-
-
-
Panel No 1. (For A.C and Non-A.C P Panel for Law of Governance)
i) Incomming: – • 160 amp 3 pole, 35kA, Fixed Thermal & fixed magnetic setting Isc=100% of Icu MCCB --- 1 No
ii) Bus Bar:- 400 Amps, 4 strip aluminium conductor
iii) Outgoing:- • 100 amp 3 pole, 25kA MCCB with Fixed Thermal & fixed magnetic setting Isc=50% of Icu MCCB --- 6 Nos.
iv) Indicating lights, 0-500V Digital Voltmetre, 0-200A Digital Ammetre, 3 Nos.--C.T's , Selector switch
2
-
-
Panel No 2. (for non-A.C at Sanskrit Centre)
i) Incomming: – • 160 amp 3 pole, 35kA, Fixed Thermal & fixed magnetic setting Isc=100% of Icu MCCB --- 1 No
ii) Bus Bar:- 400 Amps, 4 strip aluminium conductor
iii) Outgoing:- • 100 amp 3 pole, 25kA with Fixed Thermal & fixed magnetic setting Isc=50% of Icu MCCB --- 5 Nos.
• 125 amp 3 pole, 35kA MCCB with Fixed Thermal & fixed magnetic setting Isc=100% of Icu MCCB--- 1 Nos.
iv) Indicating lights, 0-500V Digital Voltmetre, 0-200 A Digital Ammetre, 3 Nos.--C.T's , Selector switch
1
-
-
Panel No 3- (for Sanskrit Centre)
i) Incomming:– • 125 amp 3 pole, 25kA,with Fixed Thermal & fixed magnetic setting Isc=50% of Icu MCCB --- 1 No
ii) Bus Bar:- 200 Amps, 4 strip aluminium conductor
iii) Outgoing:- • 100 amp 3 pole, 25kAwith Fixed Thermal & fixed magnetic setting Isc=50% of Icu MCCB --- 6 Nos.
iv) Indicating lights, 0-500V Digital Voltmetre, 0-200A Digital Ammetre, 3 Nos.--C.T's , Selector switch
1
-
-
Supplying and fixing of following way surface/recess mounting, vertical type 415 V, TP&N MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's, (But without MCBs and incomer) as required. (Note : vertical type MCB TPDB is normally used where 3 phase outlets are required.)
-
-
-
i) 8 Way (4+124), Double door
12
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 V, 10kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
i) Single pole
150
-
-
ii) Double pole
20
-
-
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
i) Triple pole and neutral 63 amps
12
-
-
Supplying and fixing single pole blanking plate in the existing MCB DB etc. as required.
50
-
-
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
8
-
-
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
40
-
-
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe FRLSom earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
24
-
-
Supply of 1100 volts rated aluminium conductor steel wire/armored XLPE of following size conductor power cable as per IS-7098 part-I with ISI marked including testing at manufacturer site etc complete as required.
-
-
-
i) 4 X 16 sq mm (from floor panel to SDB)
500
-
-
ii) 3 ½ X 70 sq mm (from main panel to floor panel)
300
-
-
iii) 3 ½ X 185sq mm (from sub-station to feeder)
425
-
-
Supplying and making end terminatio with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
-
-
-
i) 3 ½ X 25 sq mm (28 mm)
30
-
-
ii) 3 ½ X 70 sq mm (28 mm)
6
-
-
iii) 3 ½ X 185 sq mm (57 mm)
8
-
-
iv) 3 ½ X 300 sq mm (70 mm)
2
-
-
Supplying and making straight Through joint with Heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
-
-
-
i) 3 ½ X 25 sq mm
2
-
-
ii) 3 ½ X 240 sq mm
1
-
-
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required.
2450
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
-
-
-
i) Upto 35 sq. mm
350
-
-
ii) Above 35 sq. mm and upto 95 sq. mm
250
-
-
iii) Above 95 sq.mm and upto 185 sq.mm
360
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/ METAL pipe as required.
-
-
-
i) Upto 35 sq. mm
20
-
-
ii) Above 55 sq.mm and upto 95 sq.mm
10
-
-
iii) Above 95 sq.mm and upto 185 sq.mm
10
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
-
-
-
i)Upto 35 sq. mm
30
-
-
ii) Above 35 sq. mm and upto 95 sq. mm.
10
-
-
iii) Above 95 sq.mm and upto 185 sq.mm
30
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
-
-
-
i) Upto 35 sq. mm (Clamped with 1mm thick Saddle)
100
-
-
ii) Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
30
-
-
iii) Above 95 sq.mm. and upto 185 sq.mm (Clamped with 40x3mm MS flat clamp)
25
-
-
Providing, laying and fixing following dia RCC pipe NP 2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required.
-
-
-
i) 100 mm dia
12
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required
-
-
-
i) 2x2.5 sq.mm + 1x2.5 sq.mm earth wire
100
-
-
ii) 2x4 sq.mm + 1x4 sq.mm earth wire
100
-
-
SITC of SMC/DMC 2 pole copper connector of following current carrying capacity to connect two copper conductor of thickness atleast 1.5 sq mm in the loose wire box i/c connection etc as req.
-
-
-
a) 30 Amp
50
-
-
Dismantling of existing feeder pillar/floor pannels i/c connections and carriage of same from site to the store or suitable location etc as req.
5
-
-
Evaluation Notes How It Works ?