Jamia Millia Islamia Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Jamia Millia Islamia - JMI Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date2 May 2024
Closing Date11 May 2024
Tender Amount₹ 23,44,125
Costs
EMD
₹ 46,900Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_JMI_805772_1Bid Award Id
ViewTender No
JMI/BD/E- NIT/No.12/2024-25Tender Authority
Jamia Millia Islamia ViewPurchaser Address
-Website
http://https://www.jmi.ac.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
JMI/BD/E- NIT/No.12/2024-25 for Comprehensive Annual Maintenance Contract for Air Conditioning Units includes Tower Type, Cassette Type, Ductable Type, Package Type Split A.C. Unit and Treated Fresh Air Units etc. installed at various sites at Jamia Milli
JMI/BD/E- NIT/No.12/2024-25 for Comprehensive Annual Maintenance Contract for Air Conditioning Units includes Tower Type, Cassette Type, Ductable Type, Package Type Split A.C. Unit and Treated Fresh Air Units etc. installed at various sites at Jamia Milli
BOQ Items
Name of Sites:- CAD Lab Computer lab civil Engineering, Mohibbul Hasan (V.C.Archive), Premchand and urdu archive, Drawing Hall D/o Mechanical Engineering F/o Engg. & Tech.,Nelson Mandela (Peace & Conflict), Director Room University Polytechnic, D/o Physiotherapy, 3rd Floor Placement Cell F/O Engg. & Tech.,New Library, 1st floor Dean office at F/o Engg. & tech.), Department of Theoretical Physics, Meer Taqi Meer, CIT, M.F.Hussain Art Gallery, D/o Tourism, Humanities & Languages, Jamuna Lal Bajaj, Coaching and Career Planning, M.A.Ansari Auditorium, Examination Branch, MCRC, MMAJ Library, Third World Building and Jamia Sr. Sec. School).
822.5
-
2850
Split Type Ductable Air-Conditioning Units of F/O Engg & Tech. Computer Lab Civil Engg. CAD LAB 1) 11 TR x 1 = 11.0 TR
-
-
-
Split Type Ductable Air-Conditioning Units of Mohibbul Hasan (V.C Archive). 1) 5.5 TR x 4 = 22.0 TR
-
-
-
Split Type Tower (Slim Pack) Air-Conditioning Units of Premchand Archive & Urdu Archive. 1) 3 TR x 4 = 12.0 TR
-
-
-
Cassette Air-Conditioning Units of Management Building 1) (G.F) 3TR X 4 = 12.0 TR 2) (F.F) 3TR X 4 = 12.0 TR
-
-
-
Split type Tower Air conditioning units of Drawing Hall, D/o Mechanical Engineering, F/o Engg. & Tech. 1) 3.5 TR x 4 = 14.0 TR
-
-
-
Split type Tower Air conditioning units of Nelson Mandela (Peace & Conflict) 1) 3.5 TR x 4 = 14.0 TR
-
-
-
Split type cassette Air conditioning units of Director Room, University Polytechnic 1) 3.0 TR x 2 = 6.0 TR
-
-
-
Split type cassette Air conditioning units of Deptt. Of Physiotherapy 1) 4.0 TR x 15 = 60.0 TR
-
-
-
Split type Hi-Wall Air conditioning units of Deppt. Of Physiotherapy 1) 2.0 TR x 5 = 10.0 TR
-
-
-
Split type Cassette Air Conditioning Units. Of New Library 1st Floor at F/o Engg. & Tech.
-
-
-
1) 4.0 TR x 12 = 48.0 Tr
-
-
-
2) 3.0 TR x 02 = 6.0 Tr
-
-
-
Portable type Air Conditioning Units. Of New Library 1st Floor at F/o Engg. & Tech.
-
-
-
1) 1.0 TR x 4 = 4.0 Tr
-
-
-
Split type Cassette Air conditioning units of 3rd Floor, Placement Cell, F/o Engg. & Techonology 1) 3.0 TR x 3 = 9.0 TR 2) 2.0 TR x 6 = 12.0 TR
-
-
-
Cassette type AC unit of Bsc. Aeronautics, ., 1st floor at Dean Office, F/o Engg. & Tech. 1) 4.25 TR x 2 = 8.5 TR 2) 2.0 TR x 1 = 2.0 TR
-
-
-
Cassette type AC unit of Lab No. 214, Computer Engineering, F/o Engg. & Tech. 1) 4.25 TR x 2 = 8.5 TR
-
-
-
Cassette type AC unit of Seminar Hall(2nd Floor) and Library (3rd Floor), Department of theoretical Physics. 1) 2.0 TR x 7 = 14.0 TR
-
-
-
Cassette type A.C. Unit at Lab at Social works 1) 3.0 TR x 02 = 6.0 TR
-
-
-
Tower type A.C. Unit at Multipurpose hall, Jamia Sr. Sec. School. 1) 4.0 TR x 10 = 40.0 TR
-
-
-
Split Type Ductable Air-Conditioning Units of Khayaban e Ajmal Mir Taqi Mir. 1) 17 TR x 2 = 34.0 TR 2) 7.5 TR x 1 = 7.5 TR
-
-
-
Split Type Tower Air Conditioning Unit of Khayanan e Ajmal Mir Taqi Mir 1) 3.0 TR x 4 Nos. = 12.0 TR
-
-
-
Split type venture slimeline Tower Air conditioning Units of Seminar hall at Coaching and Career Planning
-
-
-
1) 3.0 Tr x 04 = 12.0
-
-
-
Split type cassette Air conditioning units of D/o Tourism, Humanities & Language 1) 3.0 TR x 4 = 12.0 TR
-
-
-
Split type Cassette Air conditioning units of Jamuna Lal Bajaj 1) 3.0 TR x 4 = 12.0 TR
-
-
-
Split type Hi-wall Inverter Air conditioning units of Jamuna Lal Bajaj 1) 2.0 TR x 1 = 2.0 TR
-
-
-
Split type Ductable Air conditioning units of M.F.Hussain Art Gallery 1) 8.5 TR x 1 = 8.5 TR 2) 5.5 TR x 2 = 11.0 TR
-
-
-
Split Type Ductable Air-Conditioning Units of CIT. 1) 16.5 TR x 4 = 66.0 TR 2) 11 TR x 3 = 33.0 Tr 3) 3 TR x 2 = 6.0 TR 4) 5.5 TR x 1 = 5.5 TR
-
-
-
Cassette Type air-Conditioning Units of CIT. 1) 3 TR x 2 = 6.0 TR
-
-
-
TFA Units of CIT. 1) 5 TR X 2 = 10.0 TR 4.5 TR x 1 = 4.5 TR 3) 3.75 TR x 2 = 7.5 TR
-
-
-
Split type Ductable Air conditioning units of M.A.Ansari Auditorium 1) 11.0 TR x 6 = 66.0 TR 2) 10.0 TR x 2 = 20.0 TR
-
-
-
Split type Ductable Air conditioning units of MCRC New Block. 1) 17.5 TR x 3 = 52.5 TR 2) 12.0 TR x 1 = 12.0 TR
-
-
-
Split Type Ceiling suspended Cassette Type air-Conditioning Units of Media Resource centre(MCRC). 1) 4 TR x 3 = 12.0TR
-
-
-
Split Type Tower (slim pack) Air-Conditioning Units of Digital Photo Lab(MCRC). 1) 3 TR x 3 = 9.0 TR
-
-
-
Split Type Ceiling suspended Three phase Cassette Type air-Conditioning Units of P.C.R-1 Room (MCRC). 1) 2.2 TR x 3 = 6.60 TR
-
-
-
Split Type Ceiling suspended Three phase Cassette Type air-Conditioning Units of P.C.R-2 Room (MCRC). 1) 2.2 TR x 2 = 4.40 TR
-
-
-
Split Type Ductable Three phase air-Conditioning Units of Old N.L.E. Ground Floor (MCRC). 1) 5.5 TR x 2 = 11.0 TR
-
-
-
Split Type Ductable Three phase air-Conditioning Units of Radio Studio Ground floor, New Building (MCRC). 1) 3.5 TR x 1 = 3.5 TR
-
-
-
2) 3.0 TR x 1 = 3.0 TR
-
-
-
Split Type Ductable Three phase air-Conditioning Units of LD-1,LD-2 & Master Control Room (MCRC). 1) 3.0 TR x 1 = 3.0 TR
-
-
-
2) 3.5 TR x 1 = 3.5 TR
-
-
-
Split Type Cassette Three phase air-Conditioning Units at Multimedia Lab, Ist Floor, New Building, MCRC. 1) 4.0 TR x 3 = 12.0 TR
-
-
-
Split Type Tower type Three phase air-Conditioning Units at Library, Ground Floor, MMAJ Building. 1) 3.0 TR x 3 = 9.0 TR
-
-
-
Split Type Tower type Three phase air-Conditioning Units at Conference Hall, 1st floor, Third World Building. 1) 3.0 TR x 3 = 9.0 TR
-
-
-
Tower type Split Air Conditioning unit of Printing room at 1st floor, Examination Branch. 1) 3 TR X 2 = 6.0 TR
-
-
-
The rates are including all taxes, cartage and contractor's profit.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements