Inter University Accelerator Centre Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Inter University Accelerator Centre - IUAC Tender
Civil And Construction
Building Construction
Eprocure
Opening Date22 Dec 2023
Closing Date11 Jan 2024
Tender AmountRefer Documents
Costs
EMD
₹ 38,000Document Cost
₹ 10Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_IUAC_786978_1Bid Award Id
ViewTender No
IUAC/NIT/17/HAR/2023-24Tender Authority
Inter University Accelerator Centre ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Following civil works in IUAC campus 1 Construction of Badminton court including light poles provision in Football Ground 2 Partial covering with GI chain link fabric fencing of existing Badminton court situated near Kalptarua resident
BOQ Items
Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer-in-charge. Circular manhole 122 cm diameter and 1.68 m deep
2
-
-
Providing, laying and jointing glazed stoneware pipes class SP-1, 300 mm diameter with stiff mixture of cement mortar in the proportion of 1:1 (1 cement: 1 fine sand) including testing of joints etc. complete
25
-
-
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design, 300 mm pipe:
25
-
-
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) as per standard design: With 20x20 mm square bar
6
-
-
Making connection of drain or sewer line (For pipes 100 to 250 mm diameter) with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement: 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete:
2
-
-
Supplying and fixing C.I. cover without frame for manholes :500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg
1
-
-
Providing and laying in position cement concrete of 1:2:4 (1 cement: 2 coarse sand (zone-III): 4 graded stone aggregate 20 mm nominal size
16
-
-
Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in cement mortar 1:6 (1 cement :6 coarse sand) in foundation and plinth
7
-
-
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand(zone-III): 4 graded stone aggregate 20mm nominal size).
20
-
-
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
10
-
-
Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 with Cement mortar 1:6 (1 cement: 6 coarse sand) in superstructure above plinth level up height of 4 mtr.
5
-
-
Providing and laying Steel reinforcement (Thermo-Mechanically Treated bars) for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
150
-
-
Reinforced cement concrete work with 1:1.5:3 (1 cement: 1.5 coarse sand: 4 graded stone aggregate 20 mm nominal size). in lintels, bands above plinth level, including the cost of centring, shuttering, finishing but excluding the cost of reinforcement.
11
-
-
Supplying and filling in plinth with Jamuna sand under floors, including watering, ramming, consolidating and dressing complete.
20
-
-
Providing and laying in position cement concrete of 1:3:6 (1 cement :3 coarse sand:6 agg.) including the cost of centring and shuttering in plinth/ floor
5
-
-
P/F 15 mm cement plaster of 1:4 (1 cement: 4 coarse sand) on brick wall
120
-
-
Extra for providing and mixing waterproofing compound of approved quality as per manufacturer’s specification in cement concrete (Pidilite LW + or equivalent of other repute).
15
-
-
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying two or more coat of PU Enamel paint including priming coat of approved steel primer all complete
1200
-
-
P/F Chequered precast red coloured cement concrete tiles 20 mm thick in ramp floor, jointed with neat cement slurry mixed with pigment (Light shade pigment using white cement) to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) including providing/maintaining proper slope on ramp.
5
-
-
Providing and fixing wall cladding on the outside of brick wall/ramp height with 12 mm thick precast Glass Fibre reinforced concrete (GRC) panel of uniform colour and size jointed with neat cement slurry / dry fixed with S.S /M. S fixture, including finishing /grouting mixed with pigment (Light shade pigment using white cement) to match the shade of panel and cleaning etc. complete, on 12 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).
40
-
-
Providing and laying Non-Pressure NP-3 class (Medium duty) R.C.C. pipes ,450 mm dia, including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete
15
-
-
Providing and fixing stainless steel (grade 304) railing (50 mm Dia) made of hollow tube, channels plates etc., including welding, grinding, buffing, polishing and making curvature and fitting the same with necessary accessary & stainless-steel dash fastener, stainless stell bolt etc. of required size, on the top of the floor or the wall with suitable arrangement as per approval of Engineer.
80
-
-
Providing and applying white cement-based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
100
-
-
P/A one coat of cement primer on all internal/external walls and ceiling before application of paint
100
-
-
Distempering with two or more coat of oil bound washable distemper including the base coat of cement primer of approved brand and make to give an even shade
100
-
-
P/A two or more coat of synthetic enamel paint of approved make and colour to give an even shade
290
-
-
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
110
-
-
Providing & fixing outdoor sports flooring with modified PP (Polypropylene) modular tile of minimum size 304.8 x 304.8 x 15.7 mm, manufacturing based on elastic material technology REBOGRID ELITE tiles or equivalent including edge strip, line marking with reflective tape/paint as required complete as per direction of IUAC Engineer
90
-
-
Providing & fixing Badminton pole set of 2 with net & other accessories complete as per direction of IUAC Engineer
1
-
-
Supplying and fixing retro reflective signage boards fixed on made up of 2 mm thick aluminium sheet, letters, borders etc. as per IRC: 67-2001 in silver white with blue colour back ground as approved by Engineer-in-charge, rectangular area of the sheet only shall be measured for payment).
3
-
-
Hire charges for hire the Hydraulic Excavator (3D) of minimum of 1 cum bucket capacity or Front-end loader 1 cum bucket capacity (incl. POL) including driver and fuel and all overhead and cost expenditure complete in side of IUAC Complete (for minimum of 6 hours in single day)
10
-
-
Providing and fixing G.I. chain link fabric fencing, Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia. not less than 5 mm in required colour and shade of required width in mesh size 50x50 mm including strengthening with 2 mm dia. wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.
50
-
-
P/F Nursery/Horticulture Green cloth on existing MS wire mesh/section with binding wire for existing badminton ground to prevent cross air ventilation complete as per the direction of Engineer.
50
-
-
Providing and fixing precast RCC Bench made with Five RCC planks of size 1500mm x 100mmx50mm, shall be cast using M-30 Grade grey cement mixed with 3% red pigment and each plank reinforced with 2nos.10mm dia. TMT bars along the length and 10 Nos. 4mm dia. mild steel bars along the width and having 12mm dia. galvanized bolts for fixing these planks on the legs. This item shall govern the provision of supply, erecting and installation of precast concrete reinforced benches with back rest, made by using vibro- compaction technique and
with reinforcement as detailed above. Compressive strength shall be not less than 30 MPa at 28 days. TMT reinforcement of dia. 10mm shall be used as main reinforcement bar and 4mm dia. mild steel bars shall be used as stirrups & connections with 12mm dia. x 65mm long galvanized steel CSK (Countersunk) bolts for connecting seating plank with leg and half threaded carriage bolts & nuts with EVA for connecting back rest plank with leg., Paint: Red colour acrylic based paint should be used. RCC Base Supports: Two number of legs manufactured using M30 grade grey cement concrete of back height 1000mm, front height 400mm, bottom width 620mm with 100mm thickness. Each leg shall be reinforced with 4 nos. of 10mm dia. TMT bars complete as per IUAC engineer Direction
4
-
-
Electrical Work Supplying, erection & testing of 12-meter (12000mm) height swaged type steel tubular pole made out of heavy-duty mild steel tube, PU painted silver/grey colour, having suitable frame for mounting single 100-watt LED flood light fittings. The bottom portion (6000mm long) should be with 194 mm dia., 4.85 mm thick, middle portion (3000 mm long) should be of 170 mm dia. 4.5 mm thick and the top portion (3000mm long) with 140 mm dia., 4.5 mm thick pipe & should have arrangement to fix climbing ladder & brackets. The pole should have a suitable size pole box of Hensel make at the bottom comprising four-way 25 Amp. Connector terminal and a 6 Amp SPMCB, the base plate of pole should be 16 mm thick and minimum 450mmX450mm size duly welded with pole complete as required. Note: An additional arrangement for climbing up on pole with be made with MS welded ladder after 6 ft height as per direction of Engineer In charge on a later stage at site and required material items payment to be made in relevant items
4
-
-
Supplying, installation, testing & commissioning of LED based 100-watt Flood Light Fittings with high efficiency, optical reflector for proper light distribution at 120 Deg., having single piece pressure die cast aluminium housing with built in heat sinks. The housing shall have two compartments, one for LED Trays & other for LED driver & mains cable entry. The optical & electrical compartments, should be sealed with silicon Gasket, toughened Glass and shall confirm to IP 66 protection. (Make: Crompton Greaves/ Philips / Halonix /Havells /Wipro.
8
-
-
Providing & making RCC foundation of 1000mm(D)X500mmX500mm size with 1:1.5:3(1Cement, 1.5 Coarse, 3 Stone aggregate) complete with 12 mm dia. M.S. bar for reinforcement along with centring & shuttering i/c supplying & fixing 500mm long, 16mm dia. J type G.I, coated foundation bolt/ Anchor bolt with template suitable for 12.0mtr. Pole completes with excavation the soil & refilling, ramming, curing etc. as rqd.
4
-
-
Supplying of 3C×16 sq. mm. XLPE insulated, PVC sheathed Aluminium conductor cable for rated voltage of 1100 volts grade conforming to IS :7098 (part-1)/88 with amendment no. 1 armoured with galvanized steel strip (ISI mark) Make – Havells / Poly cab/Nicco
170
-
-
Supply and laying of 3-inch diameter PVC flexible corrugated pipe after digging of cable trench of minimum 450 mm deep and refilling the same
150
-
-
Providing & fixing/Laying 8 SWG dia. G.I. wire along with power cable for loop earthing as reqd.
340
-
-