Institute Of Liver And Biliary Sciences Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 19,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ILBS_259822_1Tender No
ILBS/2024/GEN/BS/01Tender Authority
Institute Of Liver And Biliary Sciences ViewPurchaser Address
-Website
http://https://www.ilbs.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Renovation of Bronchoscopy Suite at ILBS
Annexure - H (Price Bid)
BOQ Items
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
5
-
-
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :
-
-
-
Cement mortar 1:4 (1 cement : 4 coarse sand)
20
-
-
12 mm cement plaster of mix :
-
-
-
1:4 (1 cement: 4 coarse sand)
55
-
-
Paint Work
-
-
-
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
55
-
-
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content.
-
-
-
With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
55
-
-
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.
-
-
-
Two coats
150
-
-
Gypsum Ceiling Work
-
-
-
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long drywall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of drywall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer Suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cut-outs made with frame of perimeter channels Suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting
-
-
-
12.5 mm thick tapered edge gypsum moisture resistant board designer fall ceiling with cove.
10
-
-
Aluminium partition work
-
-
-
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately)
-
-
-
For fixed portion
-
-
-
Powder coated aluminium (minimum thickness of powder coating 50 micron)
25
-
-
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
-
-
-
Powder coated aluminium (minimum thickness of powder coating 50 micron)
20
-
-
Supply and installation of manually operated sliding door arrangements as per the direction of Engineer-In-Charge.
1
-
-
Providing and fixing 12 mm thick pre-laminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer in-charge.
-
-
-
Pre-laminated particle board with decorative lamination on both sides
10
-
-
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item):
-
-
-
With Toughened glass panes of 88mm thickness (weight not less than 20 kg/sqm)
10
-
-
Wooden Work
-
-
-
Providing and fixing wooden work station with pedestal and wall mounted wooden cup boarded with 19mm thick one side decorative and other side balancing lamination factory pressed BWP grade Marine/HDHMR/WPC ply as per IS 710 of approved brand including drawer handle, channel and 2mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineer in- charge.(Payment of providing and fixing auto closing hinges shall be paid separately) Note: Decorative Laminate will be approved by Engineer-In-Charge
15
-
-
Providing and fixing Stainless steel door latch with necessary screws etc. complete :
-
-
-
300x16x5 mm
20
-
-
Providing and fixing stainless steel soft closing heavy type telescopic drawer channels of approved make 500 mm long with screws etc. complete as per directions of Engineer- in-charge.
6
-
-
Providing/Fixing/Installation of Roller Window Blind, of approved Shade: Sunscreen 0% / Blackout as per Engineer-In-Charge.
2.5
-
-
Wall Panelling Work
-
-
-
Providing and fixing panelling on walls (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick :
-
-
-
Ply Board 12 mm thick
-
-
-
Pre-laminated Ply board with decorative lamination on one side and balancing lamination on other side, Grade I, Type II IS: 12823 marked as per the direction of the Engineer-In-Charge.
35
-
-
Tile Work
-
-
-
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete
70
-
-
Metal Ceiling Work
-
-
-
Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm centre to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centres with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with
-
-
-
GI Metal Ceiling Clip in plain Bevelled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.
60
-
-
Vinyl Flooring Work
-
-
-
Providing 2mm thick homogeneous PVC Vinyl flooring of approved make & quality with total weight 2800g/sqm polyurethane reinforced (PUR) abrasion group P: 0.15mm, residual identification approximately 0.3mm, caster wheel test qualified, dimensional stability 0.4% static electrical charge 2kv, impax sound reduction approximately +4db good resistance of scratch, slip, chemical and fire doesn't favor in growth of bacteria no damage of furniture layer thickness 0.7mm cut resistant to heat 0.8mm, slip resistant R9u0.30 on polished smooth base floor of terrazzo/granite/tile flooring of first grade quality, the rate shall include for cutting, fitting, fixing hot welding and cove former for skirting and making good as per the direction of Engineer-in charge.
90
-
-
Signage Work
-
-
-
Fabrication and installation of LED Signage of appropriate size and Name with acrylic sheet, LED lighting and all necessary fitting and fixtures to make the signage good and fixed on the Door Frame with all complete as per direction of Engineer-In-Charge.
1
-
-
Supply and installation of signage boards as per the direction of Engineer-In-Charge.
3
-
-
Automatic Sliding Door
-
-
-
Providing and Fixing of sensor based auto Sliding Door Operator for aluminium door with Suitable fixing arrangement on wall/lintel by Suitable fasteners with alternate switch arrangements for opening of door with all necessary electrical wirings/SMPS and palm sensor with all complete as pert the direction of Engineer-In charge
1
-
-
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
-
-
-
1 or 2 Module (75mmX75mm)
3
-
-
Supplying and fixing Suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
6
-
-
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
-
-
-
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
50
-
-
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
50
-
-
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
-
-
-
1 run of cable
50
-
-
2 run of cable
50
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
-
-
-
20 mm
50
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
-
-
-
Telephone socket outlet RJ-11
1
-
-
Internet socket outlet RJ-45
2
-
-
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker Suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
Single pole
2
-
-
SITC of LED ceiling light (slim panel recess type 2'X2'), 36 watt 3600 lumens
4
-
-
SITC of LED ceiling light (square recess type), 18 watt
4
-
-
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
-
-
-
0.8 mm / 22 Gauge
15
-
-
Supply, installation, testing and commissioning of inline exhaust fan (950-1050 CFM) in the duct to create negative pressure in the procedure room of the bronchoscopy
1
-
-
Dismantling/ Removing Existing MS Pipes including cutting etc. from the working site
1
-
-
Providing ,laying ,testing & commissioning of C class heavy duty MS Pipe confirming to IS 3589/IS1239 including welding ,fitting like elbow tees flanges tapers not bolts gaskets etc. and fixing the pipe on the wall/ceiling with Suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required
-
-
-
25 mm dia
25
-
-
50 mm dia
15
-
-
Supplying, Fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nut bolts, washers, gaskets confirming to IS 13095 of following sizes as required:
-
-
-
50 mm dia
1
-
-
25 mm dia
1
-
-
Providing ,fixing ,testing & commissioning of 15mm dia quartzoid bulb type sprinkler of rating 68 degree centigrade with required accessories:
-
-
-
Upright sprinkler
10
-
-
Supplying, Fixing, testing and commissioning of multisensory detector, optical/thermal ,model no AVENAR 4000,FAP-425-OTR with the integration of the existing system/panel with required accessories
10
-
-