Institute Of Liver And Biliary Sciences Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 19,200Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ILBS_260202_1Tender No
ILBS/2024/GEN/VL/03Tender Authority
Institute Of Liver And Biliary Sciences ViewPurchaser Address
-Website
http://https://www.ilbs.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
NIT_Tender Document for Renovation of Virology Extension Lab at LB, PH-I, ILBS.
Tender Document for Renovation of Virology Extension Lab at LB, PH-I, ILBS.
BOQ Items
1:3 (1 cement : 3 fine sand)
95
-
-
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
120
-
-
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.
-
-
-
With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
600
-
-
Wall painting with acrylic emulsion paint , having VOC content less than 50 grams/litre of approved brand and manufacturer, including applying additional coats whenever required to achieve even shade and colour
-
-
-
Two coat
600
-
-
Providing 2mm thick homogeneous PVC Vinyl flooring of approved make & quality with total weight 2800g/sqm polyurethane reinforced (PUR) abrasion group P: 0.15mm, residual identification approximately 0.3mm, caster wheel test qualified, dimensional stability 0.4% static electrical charge 2kv, impax sound reduction approximately +4db good resistance of scratch, slip, chemical and fire doesn't favor in growth of bacteria no damage of furniture layer thickness 0.7mm cut resistant to heat 0.8mm, slip resistant R9u0.30 on polished smooth base floor of terrazo/granite/tile flooring of first grade quality, the rate shall include for cutting, fitting, fixing hot welding and cove former for skirting and making good as per the direction of Engineer-in charge.
170
-
-
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
-
-
-
12.5 mm thick tapered edge gypsum moisture resistant board
210
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
-
-
-
1 or 2 Module (75mmX75mm)
27
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
10
-
-
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
-
-
-
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
50
-
-
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
50
-
-
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
50
-
-
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
50
-
-
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
50
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
-
-
-
Group C
5
-
-
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
-
-
-
1 run of cable
150
-
-
2 run of cable
250
-
-
3 run of cable
100
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
-
-
-
20 mm
50
-
-
25 mm
100
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
-
-
-
Telephone socket outlet RJ-11 (Legrand make)
9
-
-
Internet socket oulet RJ-45 (Legrand make)
18
-
-