Indira Gandhi National Centre For The Arts Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 42,626Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_IGNCA_633303_1Bid Award Id
ViewTender No
04/IGNCA/SD/EMU/2021-22Tender Authority
Indira Gandhi National Centre For The Arts ViewPurchaser Address
-Website
http://http://ignca.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Construction of temporary shed near Back Gate for storage at Janpath Hotel, IGNCA, New Delhi
Construction of temporary shed near Back Gate for storage at Janpath Hotel, IGNCA, New Delhi
Construction of temporary shed near Back Gate for storage at Janpath Hotel, IGNCA, New Delhi
BOQ Items
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm
nominal size)
14
-
347.9
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
20
-
1953.05
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes
and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
55
-
7590.45
12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand)
250
-
254.25
15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand)
250
-
292.85
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to
prepare the surface even and smooth complete.
500
-
115.15
Finishing walls with Acrylic Smooth exterior paint of required shade :
13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming
coat of exterior primer applied @ 2.20 kg/10 sqm)
250
-
164.7
Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable
priming coat to give an even shade.
250
-
117.75
Tile brick masonry with common burnt clay F.P.S. (non modular) tile bricks of class designation 10 in plain arch work in superstructure above plinth and upto floor five level in cement mortar 1:4 (1 cement : 4 coarse sand) including centering
and shuttering complete.
1
-
15551.35
Tile brick masonry with common burnt clay F.P.S. (non modular) tile bricks of class designation 10 in superstructure above plinth level up to floor V level in cement mortar 1:6 (1 cement : 6 coarse sand).
4
-
10808.25
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt
hinges and screws and applying a priming coat of approved steel primer.
10.13.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block
15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate
20 mm nominal size).
100
-
106.45
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the
end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation
complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming
to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.
10.6.1 80x1.25 mm M.S. laths with 1.25 mm thick top cover
5
-
2944.1
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges
bright finished of required size with necessary screws. Kiln seasoned and chemically treated hollock wood
9.9.2.1 35 mm thick
6
-
2951.35
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 150x10 mm
24
-
52.55
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 100 mm
12
-
27.95
Applying priming coat:
13.50.1 With ready mixed pink or Grey primer of approved brand and manufacture on
wood work (hard and soft wood)
6
-
57.05
Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and
manufacture on steel galvanised iron/ steel works
10
-
50.7
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
13.61.1 Two or more coats on new work
16
-
121.55
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm
nominal size)
20
-
5789.6
Providing & fixing Link O Line right shutter lock with 02 long keys, 3 turn through lock, brown coolour or as per direction of Engineer in-charge.
2
-
928
Providing and laying cement concrete in retaining walls, return walls, walls (any
thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor
blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:
4.2.2 1:1½:3 (1 cement : 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm
nominal size).
0.5
-
8976.45
Centering and shuttering including strutting, propping etc. and removal of form work for :Columns, piers, abutments, pillars, posts and struts
5
-
733.7
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window
sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm
nominal size).
0.6
-
9763.8
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
60
-
83.5
Centering and shuttering including strutting, propping etc. and removal of form
forLintels, beams, plinth beams, girders, bressumers and cantilevers
5
-
552.05
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab,
including rubbing and polishing complete with base of cement mortar 1 : 4 (1cement : 4 coarse sand) :
11.26.1 25 mm thick
150
-
1531.85
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped
washers etc. complete. Hot finished seamless type tubes
2450
-
157.5
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm
(+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester
top coat 15-18 microns using self drilling/ self tapping screws complete : 12.51.1 Ridges plain (500 - 600mm)
25
-
416.3
Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete.
8.8.1 Wedge expansion type Fastener with threaded dia 12 mm
96
-
55.1
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated
thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade,
5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid
scratches during transportation and should be supplied in single length upto 12
873 SUB HEAD : 12- ROOFING
metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling
/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in
horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses
and including cutting to size and shape wherever required.
170
-
627.55
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:
(a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.
(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour mand shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.
(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall withaluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
35
-
4309.8
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3
coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick
bed of dry brick ballast 40 mm nominal size, well rammed and consolidated
and grouted with fine sand, including necessary excavation, levelling &
dressing & finishing the top smooth.
4
-
614.05
Wiring for light point/ fan point/ exhaust fan point/ call bell pointwith 1.5 sq.mm FRLS PVC insulated copper conductor singlecore cable in surface / recessed steel conduit, with modularswitch, modular plate, suitable GI box and earthing thepointwith 1.5 sq.mm FRLS PVC insulated copper conductor singlecore cable etc. as required. Group C
22
-
1213
Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
100
-
208
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box includingconnections but excluding modular plate etc. as required.
4
-
342
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recessetc. as required. 3 Module (100 mmX75 mm)
8
-
267
Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections butexcluding modular plate etc. as required. 5/6 A switch
8
-
85
3 pin 5/6 A socket outlet
8
-
111
Supplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) 8 way, Double door
1
-
1760
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required. Single pole
6
-
199
Double pole
1
-
556
Supplying ,Installation, testing and commissioning of 4 ft 22/24watt LED batten fitting with integral electronic driver and LED tube operated on 230vilt 50Hz AC Supply on surface with mounting arrangement, connections etc comp;ete with all accessories
20
-
750
Supplying, Installation, testing and commissioning of 1400mm sweep area ceiling fan including witing and down rods of standard size(upto 30cm) with 1.5mm FRLS PVCinsulated copper conductor single core cable, including providing and fixing. Including MS Hooks of minimum 8mm dia.
4
-
3500
Supplying, Installation, testing and commissioning of 300 mm sweep heavy duty exhaust fan in the existing opening,
4
-
3000
Extra for fixing the louvers/shutters complete with frame for the exhaust fan of all sizes
4
-
168
Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed steel conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
50
-
356