India Trade Promotion Organisation Tender
... More
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 1,83,300Document Cost
₹ 1,180Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_ITPO_557799_2Bid Award Id
ViewTender No
169 ITPO-(1)/E-E/20-21/1993Tender Authority
India Trade Promotion Organisation ViewPurchaser Address
-Website
http://http://indiatradefair.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
CHWP 800 GPM suitable head in York Plant room
2
-
-
... More
200 mm NRV for CHWP
2
-
-
... More
200 mm Butterfly Valve for CHWP
2
-
-
... More
200 mm Y Strainer for CHWP
2
-
-
... More
SITC of following sizes of MS "C" Class Pipe/valves complete with all filltings, Support duly insulated,wherever required suitable deep excavation and refilling of trench with making good the damages, PUF Insulation ( 32kG/m3 ) alongwith Fibre Glass & StarBond Shall also be used for external application whereas Nitrile Rubber / XLPE ( 32mm ) shall be used for internal application complete etc as required.
-
-
-
... More
SITC of following size of CHW Pipe at required location
-
-
-
... More
450 mm dia 7mm thick CHW Pipe
60
-
-
... More
300 mm dia 7mm thick CHW Pipe
290
-
-
... More
250 mm dia 6.35mm thick CHW Pipe
145
-
-
... More
200 mm dia 6.35mm thick CHW Pipe
90
-
-
... More
150 mm dia 6.35mm thick CHW Pipe
40
-
-
... More
SITC of following size of CHW Pipe at required location
-
-
-
... More
150 mm Plant Isolation Valve
4
-
-
... More
200 mm Plant Isolation Valve
2
-
-
... More
250 mm Plant Isolation Valve
2
-
-
... More
350 mm Plant Isolation Valve
2
-
-
... More
SITC of Balancing Valve
-
-
-
... More
250 mm Balancing Valve for Plant
2
-
-
... More
350 mm Balancing Valve for Plant
1
-
-
... More
SITC of following size of Condenser Pipe at required location.
-
-
-
... More
500 mm, 7mm thick CWP Pipe
80
-
-
... More
300 mm, 7mm thick CWP Pipe
15
-
-
... More
200 mm, 6.35mm thick CWP Pipe
40
-
-
... More
100 mm, 6.35mm thick CWP Pipe
10
-
-
... More
Starter Panel for York Plant CHW Pump
2
-
-
... More
Temperature Gauge
20
-
-
... More
Pressure Gauge
20
-
-
... More
Automatic Purge Valve
5
-
-
... More
25mm Drain Valve
10
-
-
... More
Shifting of 2 Nos Trane Chillers alongwith Electrical Panel, CHWP, CWP etc. including dismentalling and re-installation by Providing and Making suitable Foundations,antivibration arrangements,Electrical Connections for Chillers,Pumps etc. by providing suitable size and length cables,end terminations etc. and Recommissioning of Chillers,pumps etc. as an integral part of the scheme.
1
-
-
... More
Shifting & Reinstallation,Recommissioning of Cooling Tower for Trane Chillers along with Electrical Panel etc. including dismentalling and re-installation by Providing and Making suitable Foundations,Electrical Connections etc. by providing suitable size and length cables,end terminations, repair inclding replacement of brocken header,nozels,other accessaries etc. complete as required.
2
-
-
... More
Recommissioning,resetting,balancing of entire system in integrated mode including providing data such as chilled water,condenser water flow rates,operating points for varios equipments,doing seasonal tests during summer and Monsoon etc. complete as required.
1
-
-
... More
SH-2(Dismantling and buyback)
-
-
-
... More
Dismantling and buyback of following equipment with accessaries including making good the damages etc as required.
-
-
-
... More
Buy-Back (ie minus)Amount of Trane Chiller.
1
-
-
... More
Buy-Back (ie minus) Amount of Trane Primary CHWP.
1
-
-
... More
Buy-Back (ie minus) Amount of Trane CWP.
1
-
-
... More
Buy-Back (ie minus)Amount of York Chiller.
2
-
-
... More
Buy-Back (ie minus) Amount of York Primary CHWP.
2
-
-
... More
Buy-Back (ie minus) Amount of York CWP.
3
-
-
... More
Buy-Back (ie minus) Amount of York Elect Panel
1
-
-
... More
Buy-Back (ie minus) Amount of CT, Piping, Valves & Accessories
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements