India Tourism Development Corporation Limited Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 63,100Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_ITDC_145900_1Bid Award Id
ViewTender No
Ah/Engg-civil/B-hall/2022Tender Authority
India Tourism Development Corporation Limited ViewPurchaser Address
-Website
http://http://itdc.co.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Prevention of Leakage/Seepage at the terrace of the Banquet Hall and Re-Strengthing work of shop near Kendriya Bhandar at The Ashok, New Delhi
Prevention of Leakage/Seepage at the terrace of the Banquet Hall and Re-Strengthing work of shop near Kendriya Bhandar at The Ashok, New Delhi
Prevention of Leakage/Seepage at the terrace of the Banquet Hall and Re-Strengthing work of shop near Kendriya Bhandar at The Ashok, New Delhi
BOQ Items
... More
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
134
-
-
... More
Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
47.29
-
-
... More
20 mm cement plaster of mix :1:4 (1 cement: 4 coarse sand)
945.88
-
-
... More
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 ltr/sqm. by the same membrane manufacturer of density at 25°C, 0.87-0.89 kg/ltr and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane. 3mm thick
945.88
-
-
... More
Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation.
945.88
-
-
... More
Providing Laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat: With common burnt clay F.P.S. (non modular) brick tiles of class designation 10
945.88
-
-
... More
Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In- Charge Upto and including 12mm dia.
70
-
-
... More
Steel reinforcement for R.C.C. work ready to use "cut and bend" rebar‟s of approved make from factory/workshop to construction site including placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
390
-
-
... More
Providing and applying the bonding coat of SBR for using of water proofing coating 2.2 Sqm/kg in 1 coat as per the direction of the Engineer-In-Charge
1015.48
-
-
... More
Shot creating the RB/RCC ceiling coloums etc with cement mortar 1:2:2(1 cement : 2 coarse sand :2 stone aggregate 6mm down gauge ) to an average thickness of 40mm with pressure of 2.3kg/cm2 over M.S welded wire mesh of 75 x 75 x 4mm tied to reinforcement with binding wire including erecting the scaffolding and dismantling the old plaster cover for RB/RCC ceiling, cleaning the reinforcement by the rust scales, removing malba from the site and disposing the same as per the direction of Engineer-In-Charge and curing the surface of shot creating for 7days including the cost of welded mesh finishing but excluding the cost of reinforcement complete as the direction of Engineer-In-Charge.
69.6
-
-
... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
187.2
-
-
... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
187.2
-
-
... More
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification Two or more coats on new work
187.2
-
-
... More
Carriage of materials by mechanical transport including loading, unloading and stacking to approved municipal dumping ground for lead upto 20 kms for all lifts, complete as per directions of Engineer-in-charge. Lime, Moorum, Building rubbish.
428.32
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements