India Tourism Development Corporation Limited Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
India Tourism Development Corporation Limited - ITDC Tender
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date27 Sep 2022
Closing Date13 Oct 2022
Tender Amount₹ 3,06,78,024
Costs
EMD
₹ 6,20,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_ITDC_130240_1Bid Award Id
ViewTender No
ITDC/Engg/Kerala/HTLT 2/2022Tender Authority
India Tourism Development Corporation Limited ViewPurchaser Address
-Website
http://http://itdc.co.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Design, Supply, Installation, Testing and Commissioning of Grid connected substation at Sivagiri, Aruvipuram, Chempazanthi and Kunnumpara at Kerala.
Design, Supply, Installation, Testing and Commissioning of Grid connected substation at Sivagiri, aruvipuram, Chempazanthi and Kunnumpara at Kerala
BOQ Items
Bus Bar mounting Surge Protection Device (with 10years OEM Warranty) Class B & Class C/ Class 1 & Class 2 and shall be tested as per IEC 61643 Part 11:2011 & UL 1449 4th edition in the Main Panel. The Surge Protection Devices shall have TOV withstand for 120 Min : 528 V and shall be with out Follow Current & Leakage Current. Protective Elements shall be single, heavy duty, distribution grade Metal Oxide Varistor (MOV) disk, assembled under pressure in an environmentally sealed aluminum casing. The Protection Modes shall be for : L & N to PE. The connections (Three Lines & Neutral) should be directly connected to rotective Earth Terminal for better response time.
Nominal voltage -230V 50/60Hz, MCOV of 350 V, Total Impulse current-50 kA (10/350µ sec) & Total Max Discharge current 560kA (8/20µ sec), Voltage protection level 1.2 kV. Short- Circuit Current rating – 65 kA/50 Hz.There shall be in built Back up fuse. Total Response time shall be 1 nano sec.-2 Nos
OUTGOINGS
250A, 25kA TP MCCB (adjustable setting) - 1 nos
160A, 25kA TP MCCB (adjustable setting) - 6 nos
100A, 25kA TP MCCB (adjustable setting) - 13 nos
Accessories as per schematic drawing.
1
-
-
Supply, installation, testing and commissioning of APFC PANEL-1 & 2 (60 kVAR) Capacitors shall be heavy duty APP with thermoplastic jelly as dielectric medium, wet cells Eccol as dielectric fluid, fully anti-explosive design incorporating 3 Phase UL approved pressure sensitive interrupter, suitable for - 40 ° C to + 70 ° C operating temperatures and there shall be 7% block reactor with each capacitor bank of same rating as capacitor. The size of panel is 1500 x 1000 x 400mm with 160A Aluminium Bus Bar. The panel shall be fabricated from a CPRI approved vendor and comply with KSEI/CPRI standards.
160A 4P 25kA MCCB incomer, APP capacitor with pf relay of 6 stages - 7% block reactor with each capacitor bank of same rating as capacitor,
20 kVAR x 2 no, 10 kVAR x 1 no
10 kVAR x 1no (Fixed Type) complete with suitable MCBs and capacitor duty contactors and all accessories as in drawing etc complete as required for the installation.
5
-
-
Supply, installation, testing and commissioning of 320/125 KVA Silent Diesel generator coupled to 415Volts alternator mounted on a commen base frame along with CPCB approved acoustic enclosure complete with all necessary accessories i.e. Manual Control Panel, Fuel Tank, Battery with leads etc. for mechanical erection and complete exhaust system & cooling system including foundation as requiered and as directed by the engineer in charge
-
-
-
320 KVA
1
-
-
125KVA
3
-
-
Supply and installation of 11kV 2-Pole Structure with Girder - pole length 9.0m in size of ISMB 175mm - 02nos, cross MS channels with length 2.25m in size of ISMC 75mm - 04 Nos, cross MS angle with length 2.25m in size of ISA 50x50x5 - 04 Nos, clamps 50x5 patti -20 m, nut & bolts complete with moulded fittings & accessories, two stays to H-pole, all structure aluminium painted with GO, DO, including loading & unloading by crane or heavy labour and shall meet all KSEB standards and requirements.
4
-
-
Supply,Unloading,conveyance, installation, testing and commissioning of Outdoor Dry type Transformer (CRT) of 315 kVA,11kV/433 V, 3 phase AN cooled, vector group DYN-11 cast resin dry type transformer with Off circuit tapings of +5% to -10% in steps of 2.5, changeable on off circuit by tap links provided, with incoming suitable for connecting 3C x 185sqmm HT cable and LV cable box suitable for connecting 2Rx3.5Cx300 Sqmm A2XFY or 3Rx3.5Cx185 Sqmm 2XFY cable with all fittings and accessories conforming to IS:2026/77. The installation shall be inclusive of all necessary accessories as recommended by the supply authority/consultants as required.
5
-
-
Supply and providing emergency push button switch control complete with suitable weather proof IP 65 thermoplastic polycarbonate enclosure including all necessary connections as required
5
-
-
Supply and installation, testing (from EB/CEIG approved laboratory) and commissioning of CT units/relays in generator and transformer complete with weather proof metallic enclousure and giving connections as required.
-
-
-
100/5A 15VA class 5P10 (Neutral CT for 315kVA Transformer)
5
-
-
100/5A 15VA class 5P10 (Neutral CT for 320kVA DG Set)
5
-
-
51G Relay
10
-
-
Supply, conveyance, erection, testing and commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board conforming IS-8623, made out of 14 SWG thick CRCA sheet, powder coated after 7 tank process, fully compartmentalised complete with hinges and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel with all necessary meters, indications, CTs etc as shown in the electrical drawing or as per the latest requirement of local authority complete with all connections and interconnections for the following: INCOMER 400A, 35kA FP MCCB (Microprocessor based) with 3O/C & 1 E/F release - 1 nos 400A, 35kA FP MCCB (Microprocessor based) - 1no 400A, 4P AC-3 Duty Contactor - 1 nos AMF Controller-1no PLC Control Module with Load Manager -1no Multifunction Meter with RS485 of size 96mm CTs 400 / 5A, CL - 1, 15 VA - 12 Nos. Digital Ammeters of size 96mm x 96mm in the range (0 -400A) - 2Nos.Digital Voltmeter of size 96mmx96mm in the range (0 - 500V) with selector switch - 2 set.RYB phase indicating lamps (lamps shall be of LED) with control fuses /MCB 2A - 2 set.Busbar 400Amps uniformly rated, continuous duty, 415Volts A/C, 3 phase and neutral Aluminium busbar with colour coded heat shrink sleeves supported on SMC type grip supports 50kA.Bus Bar mounting Surge Protection Device (with 10years OEM Warranty) Class B & Class C/ Class 1 & Class 2 and shall be tested as per IEC 61643 Part 11:2011 & UL 1449 4th edition in the Main Panel. The Surge Protection Devices shall have TOV withstand for 120 Min : 528 V and shall be with out Follow Current & Leakage Current. Protective Elements shall be single, heavy duty, distribution grade Metal Oxide Varistor (MOV) disk, assembled under pressure in an environmentally sealed aluminum casing. The Protection Modes shall be for : L & N to PE. The connections (Three Lines & Neutral) should be directly connected to Protective Earth Terminal for better response time.
Nominal voltage -230V 50/60Hz, MCOV of 350 V, Total Impulse current-50 kA (10/350µ sec) & Total Max Discharge current 560kA (8/20µ sec), Voltage protection level 1.2 kV. Short- Circuit Current rating (Isccr) – 65 kA/50 Hz.There shall be in built Back up fuse. Total Response time shall be 1 nano sec.-2
OUTGOINGS
250A, 25kA TP MCCB (adjustable setting) - 1 nos
160A, 25kA TP MCCB (adjustable setting) - 3 nos
100A, 25kA TP MCCB (adjustable setting) - 3 nos
Accessories as per schematic drawing.
3
-
-
Supply and installation of Ladder type Cable tray without cover, uniformily galvanised with 60 microns of zinc, shall be tested as per IEC 61537 and galvanisation shall conform to DIN EN 10346 / ISO 1461. The installation shall be complete with bends, connectors, couplers, all mechanical supports like threaded roads, anchor bolts of approved makes etc complete as required and as recommeded in standards. The trays should be tested for a safe working load as per the standard with a span distance of 2 meters and the deflection should be within the limits as per NEMA standards. The tray covers shall be min 1.2 mm thickness and snap fitted. The minimum size of rung shall be 35x15 mm at a span of maximum 300mm.
-
-
-
300mm x 75mm
20
-
-
300mm x 50mm
16
-
-
200mm x 75mm
50
-
-
150mm x 50mm
50
-
-
Supply, installation, testing and commissioning of floor mounting non-metallic enclosures made of thermoplastic polycarbonate of the following ways with standard dimensions suitable for fixing 4P MCCB as incomers and TP MCBs as outgoings including outgoing terminals and all accessories etc as required, enclosure should have an ingress protection of IP65 in accordance with IEC 60529, made of high quality Polycarbonate (PC – GFS) shock proof, rust free, corrosion free, acid and chemical resistant, fire retardant, self-extinguishing, having high impact against mechanical load, made of halogen and silicon free recyclable material conform to RoHS directive 2002/95/EC, UV resistant according to IEC 61439-1, having high grade internally embedded gasket made of Polyurethane ( PUR ).
3PH 6 Way (640x1250x600mm min. dimensions)
21
-
-
Supplying and fixing of the following ways, IP 43 three pole and neutral, sheet steel, Vertical distribution board, double cover 415 volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatised and powder painted including earthing, suitable for fixing 4P MCB /Isolator/RCCB as incomer and TP & SP MCBs as out going etc complete. as required with all accessories.
-
-
-
8 Way MCB VDB wit 4P MCCB Incommer-1No and outgoing of TP MCB and SP MCB
16
-
-
12 Way MCB VDB
18
-
-
6 Way TPN DB
10
-
-
4 Way TPN DB
10
-
-
Supplying and fixing of following ways, IP 43 sheet steel, SPN MCB distribution board, double cover 230 volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatised and powder painted including earthing, suitable for fixing 2P MCB /Isolator and 2P RCCB as incomer and SP MCBs as out going etc complete as required with all accessories.
-
-
-
16 Way SPN DB (18 W ENCL)
12
-
-
12 Way SPN DB (16 W ENCL)
6
-
-
Supply and laying of one number of 11kV armoured A2XFY power cable of following size with conductors of best conductivity Aluminium conforming to relevant IS7098(L), in tray, open duct etc. as required.
-
-
-
3C 300sqmm A2XFY
100
-
-
3C 185sqmm A2XFY
210
-
-
Supply and laying of one number PVC insulated and PVC sheathed / XLPE armoured power cable of 1.1 KV grade of following size conforming to relevant IS standards direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
-
-
-
3.5 core 300 sqmm XLPE Cable
100
-
-
3.5 core 240 sqmm XLPE Cable
210
-
-
3.5 core 185 sqmm Al Armoured Cable
300
-
-
3.5 core 150 sqmm Al Armoured Cable
350
-
-
3.5 core 120 sqmm Al Armoured Cable
200
-
-
3.5 core 95 sqmm Al Armoured Cable
120
-
-
3.5 core 70 sqmm Al Armoured Cable
150
-
-
4 core 10 sqmm Cu Armoured Cable
300
-
-
3 core 4 sqmm Cu Armoured Cable
400
-
-
Supply and making indoor end terminations for 11kV grade X.L.P.E cables of the following size including supply of heat shrinkable type end sealing kit of approved make and quality with all required accessories etc. as required. Conforming for IEEE
48-1990 or IS:13573
-
-
-
3C 300sqmm A2XFY
12
-
-
3C 185sqmm A2XFY
20
-
-
Supply and making end termination with brass compression gland, earth clip and aluminum lugs/ Cu lugs for following size of PVC insulated/ XLPE Aluminum/ copper conductor cable of 1.1kV grade as
required.
-
-
-
3.5 core 300 sqmm Al Armoured Cable
8
-
-
3.5 core 240 sqmm Al Armoured Cable
12
-
-
3.5 core 185 sqmm Al Armoured Cable
16
-
-
3.5 core 150 sqmm Al Armoured Cable
25
-
-
3.5 core 120 sqmm Al Armoured Cable
36
-
-
3.5 core 95 sqmm Al Armoured Cable
44
-
-
4 core 10 sqmm Cu Cable
22
-
-
3 core 4 sqmm Cu Cable
12
-
-
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
20
-
-
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
1000
-
-
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
500
-
-