Guru Gobind Singh Indraprastha University Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Guru Gobind Singh Indraprastha University - GGSIPU Tender
Electrical and Electronics
Eprocure
Opening Date20 Sep 2024
Closing Date27 Sep 2024
Tender AmountRefer Documents
Costs
EMD
₹ 79,699Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_GGSIP_262570_1Tender No
11/EE/UWD/East Campus/2024-25Tender Authority
Guru Gobind Singh Indraprastha University ViewPurchaser Address
-Website
http://http://www.ipu.ac.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
35
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
35
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 4 Sq. mm
2200
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 6 x 4 Sq. mm
500
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 1.5 sq. mm
200
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
100
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm
250
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
250
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A Switch
445
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A Switch
442
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A Socket outlet
445
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 Pin 15/16 A Socket outlet
442
-
-
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
20
-
-
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
50
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm)
50
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm)
200
-
-
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 Way (4 + 12),Double door
10
-
-
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 Way (4 + 18),Double door
6
-
-
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 Way (4 + 24), Double door
3
-
-
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
300
-
-
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral
20
-
-
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
50
-
-
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
10
-
-
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
15
-
-
Supplying and fixing TPN MCB 63 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as requiredSupplying and fixing TPN MCB 63 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required 63A
10
-
-
Supplying, Installation, Testing and Commissioning of 400 mm Wall Fan having 5 star energy rating of the approved make as per directions of Engineer-In-Charge.
10
-
-
SITC of 2'x2' recess mounting luminaries 36W with high performance LEDs & CRCA powder coated body, High efficiency long life LED package in integral module with System lumen efficacy of ≥110 lm/W, CRI 80,Color temperature 5700K, THD 10% and PF≥0.9, IP20, IK03, Life class of 50,000 hrs @ L70,Input Supply Voltage Range:150-270 V, Frequency :50-60 HZ; Internal Surge Protection:2.5 KV, System Lumen 3600.The luminaries shall be following LM79 and LM 80 report issued by LED manufacturer etc. complete as required.
25
-
-
SITC of 15 w recess mounted LED Downlighter made of Pressure die-cast aluminium heat sink for effective thermal management with heavy duty driver in PC housing ,efficacy at System level ≥110lumens/watt with system minimum 1350 Lumens, 50000 burning Hrs. @ L70,THD 10%,CCT of 5700K/6500K, IP 20, IK03, CRI 80, PF 0.9, operating Voltage Range of 140 - 277 VAC, Minimum Internal Surge Protection of 2.0KV, the luminaries shall be following LM79 and LM 80 report issued by LED manufacturer etc. complete as required.
30
-
-
Supply, installation, testing and Commissioning of 18W- 20Watt LED light 4 feet Batten Luminare having minimum system Lumen output of 2000 Lumens, minimum system efficacy of 110 Lumen/Watt, Colour temperature ( 6500K) in Cool day light, extruded Aluminium housing, Power factor 0.90 CRI80, THD20 with APFC isolated driver with efficiency of 85% Surge protection 2KV, operating voltage 150-270 50Hz AC. With LED chip make : Cree, Nichia, Philips, Lumiled, Osram, Edison, Seoul, Bridge lux, luminaries shall be complying to LM80 Report from LED manufacturer for burning life of 5,0000 Hrs and LM-79 Report from NABL accredited lab, connection with 3x1.5 sqmm FRLS PVC conductor wire etc complete as required.
30
-
-
Dismantling the 600 mmx 600 mm MS False ceiling from the ceiling and making 150-200 mm wide hole for 15-18 W downlight without making any bend and damaging the paint and re fixing at same location as per directions of Engineer-In-Charge.
30
-
-
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
25
-
-
Providing and fixing 100 x 50 mm DLP U-PVC trunking system with all accessories including flexible top cover, internal angles external angles, joints, end caps etc. complete as required.
200
-
-
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
400
-
-
Supply of XLPE insulated pvc sheated Copper conductor, armoured cable 1.1kv grade confirming to IS 7098(Part-1) 1988 4 X 16 sqmm.
100
-
-
Supply of XLPE insulated pvc sheated Copper conductor, armoured cable 1.1kv grade confirming to IS 7098(Part-1) 1988 4 X 10 sqmm.
350
-
-
Supply of XLPE insulated pvc sheated Copper conductor, armoured cable 1.1kv grade confirming to IS 7098(Part-1) 1988 3 X 4 Sqmm
500
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
350
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sqmm. (28 mm)
10
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sqmm.( 25 mm)
20
-
-
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.
100
-
-
Supply and installing following size of under floor GI (hot dip galvanized) raceways made out of 1.6mm thick sheet steel, standard length 2.5 meters, 1/2/3 compartment complete with jointing sleeves and other accessories under floor installation including cutting and chasing the floor, making good the same, placing in position and cleaning from inside complete of following sizes etc. as required. (50mm x 38mm x 1.6mm)
40
-
-
Supply and installing following size of under floor GI (hot dip galvanized) raceways made out of 1.6mm thick sheet steel, standard length 2.5 meters, 1/2/3 compartment complete with jointing sleeves and other accessories under floor installation including cutting and chasing the floor, making good the same, placing in position and cleaning from inside complete of following sizes etc. as required. (100mm x 38mm x 1.6mm)
10
-
-
Repairing of Monoblock pump set (10 HP) by replacement of worn out parts including testing and commissioning etc. as required :- (Dismantled material will be contractor's property) Rewinding of motor with copper winding wire i/c varnishing etc. as required
5
-
-
Repairing of Monoblock pump set (10 HP) by replacement of worn out parts including testing and commissioning etc. as required :- (Dismantled material will be contractor's property) Replacement of DE side ball bearing
5
-
-
Repairing of Monoblock pump set (10 HP) by replacement of worn out parts including testing and commissioning etc. as required :- (Dismantled material will be contractor's property) Replacement of NDE side ball bearing
5
-
-
Repairing of Monoblock pump set (10 HP) by replacement of worn out parts including testing and commissioning etc. as required :- (Dismantled material will be contractor's property) Replacement of Gland sleeve
5
-
-
Repairing of Monoblock pump set (10 HP) by replacement of worn out parts including testing and commissioning etc. as required :- (Dismantled material will be contractor's property) Replacement of Safety terminal plate
5
-
-
Repairing of Monoblock pump set (10 HP) by replacement of worn out parts including testing and commissioning etc. as required :- (Dismantled material will be contractor's property) Replacement of Cooling fan
5
-
-
Repairing of Monoblock pump set (10 HP) by replacement of worn out parts including testing and commissioning etc. as required :- (Dismantled material will be contractor's property) Replacement of Gland
5
-
-
Labour charges for dismantling the defective pump from the existing location reassembling, testing at workshop and at site i/c painting and to & fro. Cartage charges etc as required by replacement of worn out parts i/c testing and commissioning.
5
-
-
Repairing of pump set by replacement of worn out parts including testing and commissioning etc. as required:-
For 5-7.5 HP monoblock pump set.(Dismantled material will be contractor's property) Rewinding of motor with copper winding wire i/c varnishing etc. as required
5
-
-
Repairing of pump set by replacement of worn out parts including testing and commissioning etc. as required:-
For 5-7.5 HP monoblock pump set.(Dismantled material will be contractor's property) Replacement of DE side ball bearing
5
-
-
Repairing of pump set by replacement of worn out parts including testing and commissioning etc. as required:-
For 5-7.5 HP monoblock pump set.(Dismantled material will be contractor's property) Replacement of NDE side ball bearing
5
-
-
Repairing of pump set by replacement of worn out parts including testing and commissioning etc. as required:- For 5-7.5 HP monoblock pump set.(Dismantled material will be contractor's property) Replacement of Gland sleeve
5
-
-
Repairing of pump set by replacement of worn out parts including testing and commissioning etc. as required:- For 5-7.5 HP monoblock pump set.(Dismantled material will be contractor's property) Replacement of Gland
5
-
-
Repairing of pump set by replacement of worn out parts including testing and commissioning etc. as required:- For 5-7.5 HP monoblock pump set.(Dismantled material will be contractor's property) Labour charges for dismantling the defective pump from the existing location reassembling, testing at workshop and at site i/c painting and to & fro. Cartage charges etc as required by replacement of worn out parts i/c testing and commissioning.
5
-
-
Repairing of pump set by replacement of worn out parts including testing and commissioning etc. as required:-
For 5-7.5 HP Sump pump set.(Dismantled material will be contractor's property) Rewinding of motor with copper winding wire.
10
-
-
Repairing of pump set by replacement of worn out parts including testing and commissioning etc. as required:-
For 5-7.5 HP Sump pump set.(Dismantled material will be contractor's property) Replacement of mechanical Seal
10
-
-
Repairing of pump set by replacement of worn out parts including testing and commissioning etc. as required:-
For 5-7.5 HP Sump pump set.(Dismantled material will be contractor's property) Replacement of ball bearing
10
-
-
Repairing of pump set by replacement of worn out parts including testing and commissioning etc. as required:-
For 5-7.5 HP Sump pump set.(Dismantled material will be contractor's property) Labour charges for dismantling the defective pump from the existing location reassembling, testing at workshop and at site i/c painting and to & fro. Cartage charges etc as required by replacement of worn out parts i/c testing and commissioning.
10
-
-
Repairing and rewinding of 0.5hp pump set including testing & commissioning etc as required as per directions of Engineer In Charge.(Dismantled material will be contractor's property)
1
-
-
Repairing of pump set by replacement of worn out parts including testing and commissioning etc. as required:-
For 1.5/2 HP Sump pump set. (Dismantled material will be contractor's property) Rewinding of motor with copper winding wire i/c varnishing etc. as required
2
-
-
Repairing of pump set by replacement of worn out parts including testing and commissioning etc. as required:-
For 1.5/2 HP Sump pump set. (Dismantled material will be contractor's property) Replacement of bearing
2
-
-
Repairing of pump set by replacement of worn out parts including testing and commissioning etc. as required:-
For 1.5/2 HP Sump pump set. (Dismantled material will be contractor's property) Replacement of Sleeve
2
-
-
Repairing of pump set by replacement of worn out parts including testing and commissioning etc. as required:-
For 1.5/2 HP Sump pump set. (Dismantled material will be contractor's property) Replacement of connection Plate
2
-
-
Repairing of pump set by replacement of worn out parts including testing and commissioning etc. as required:-
For 1.5/2 HP Sump pump set. (Dismantled material will be contractor's property) Replacement of mechanical Seal
2
-
-
Lowering and Lifting of borewell Submersible pump from & to the bore of 160-200 feet bore including all required equipments as required as per directions of Engineer in charge.
2
-
-
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
300
-
-