Guru Gobind Singh Indraprastha University Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Guru Gobind Singh Indraprastha University - GGSIPU Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date13 Sep 2024
Closing Date4 Oct 2024
Tender Amount₹ 34,39,219 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Annual routine/preventaive/Curative maintenance and complete servicing of 3/4 pole, 440 volt, 50 Hz Air Circuit breaker of rating 800 Amps to 2500 Amps of ABB make at Sub Stations i.e. MSS, LSS, ASS-1 & ASS-II including cleaning the contacts with CRC liquid, testing closing/opening and tripping mechanism, charging circuits, testing control circuits, relays, fuses, indicating lights, all measuring instruments and providing jelly on male/female contacts complete as required as Annexure-III as per instructions of Engineer-in-charge and terms & conditions defined in tender document.

33

-

-

... More
Annual routine/preventaive/Curative maintenance of capacitor panel etc complete of rating 80 KVR to 425 KVR at Sub Stations i.e. MSS, LSS, ASS-1 & ASS-II including cleaning complete as required as Annexure-IV as per instructions of Engineer-in-charge and terms & conditions defined in tender document.

13

-

-

... More
Dehydration of insulating Transformer oil of 11 KV Transformers with Filteration Machine equipped with suitable capacity heating system including cost of transportation of Filteration Machine, checking dielectric strength of oil at site after dehydration complete as required.

4786

-

-

... More
Replacement of worn out Silica Gel with new Silica Gel for the breather of the Transformer complete as required.

9

-

-

... More
Providing insulating Transformer Oil for topping up of Transformer complete as required. Make:- Power/APAR/Transol etc

80

-

-

... More
Locating cable fault of under ground 11 KV, HT cables of sizes up to 630 Sq.mm with the help of Fault Locating Machine including pin pointing the location of cable fault complete as required as per direction of Engineer-in-Charge.

4

-

-

... More
Making High Pot Test of 11 KV cable with the help of High Pot Machine by providing a surge voltage between 15 KV to 18 KV after making straight through joint (excluding straight through joint) including discharging the cable after test and connecting both ends of cable with VCBs terminals after successful completion of test complete as required as per direction of Engineer-In-Charge.

4

-

-

... More
To carryingout thermography of cable end terminations of the H.T. and L.T. Panels, Transformers with H.T. & L.T. Side, Bas bar link etc. in Sub Stations i.e. MSS, LSS, ASS-1 & ASS-II and submitting the reports generated comprising of observations and thermography Images, comments and recommendation for necessary action for the following installation:

1

-

-

... More
Supply and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:70/95 sq. mm

2

-

-

... More
Supply and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:120 sq. mm

2

-

-

... More
Supply and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm

2

-

-

... More
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 70/ 95 sq. mm

1

-

-

... More
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 120 sq. mm

1

-

-

... More
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 300 sq. mm

1

-

-

... More
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 70/95 sq. mm

1

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 120 sq. mm

10

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 120 sq. mm and upto 400 sq. mm

5

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required. Upto 120 sq. mm

10

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required. Above 120 sq. mm and upto 400 sq. mm

5

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required

60

-

-

... More
Supply of heavy duty 11KV grade, XLPE insulated, PVC sheathed armoured cable with aluminium conductor for the following size with ISI mark confirming to IS : 7098 part-1 amended up to date as required. 3x95 sqmm Aluminium conductor cable

10

-

-

... More
Supply of heavy duty 11KV grade, XLPE insulated, PVC sheathed armoured cable with aluminium conductor for the following size with ISI mark confirming to IS : 7098 part-1 amended up to date as required. 3 x 120 sqmm Aluminium conductor cable

10

-

-

... More
Supply of heavy duty 11KV grade, XLPE insulated, PVC sheathed armoured cable with aluminium conductor for the following size with ISI mark confirming to IS : 7098 part-1 amended up to date as required. 3 x 300 sqmm Aluminium conductor cable

10

-

-

... More
Demolishing cement concrete manually/by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-Charge. a) Nominal concrete 1:3:6 or richer mix ( i/c equivalent design mix).

1

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drain (not exceeding 1.5m in width or 10sqm on plan),including dressing of sides and ramming of bottoms,lift upto 1.5m. Including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m (A) All kinds of soil.

8

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundation etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50m and lift upto 1.5 m

8

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level.a) 1:2:4 ( 1 Cement: 2 Coarse sand : 4 graded stone aggregate 20 mm nominal size)

1

-

-

... More
Round the clock operation of 2 Nos. 1500 & 1 No. 1010 KVA capacity, 11 KV DG sets alongwith associated installations, equipments such as Engine, Alternator, Batteries, PLC Panel, Auxiliary Panel, Coil Coolers and Air Washers which includes general equipment cleaning and daily checks etc. by deploying following manpower and as per directions of Engineer-in-charge. Skilled (Operator)

1005

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.