Dr Ram Manohar Lohia Hospital Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Dr Ram Manohar Lohia Hospital Tender

Goods
Healthcare and Medicine
Eprocure
Opening Date17 Aug 2023
Closing Date9 Sep 2023
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Digital multi-programmable pacemaker pulse generator. Mode: single chamber: VVI/AAI. Pulse generator compatible with above leads (Sl. No. 1 & 2)

1

-

-

... More
Digital multi-programmable pacemaker with lifetime warranty, 1.5 Tesla MRI compatible with Automatic capture facility for rescue pacing and automatic lead polarity switch. Mode: single chamber: VVI/AAI. With ≤6F compatible passive-fixation tined lead with ≤7F lead introducer.

1

-

-

... More
Digital multi-programmable pacemaker with lifetime warranty, 1.5 Tesla MRI compatible with Automatic capture facility for rescue pacing and automatic lead polarity switch. Mode: single chamber: VVI/AAI. With ≤6F compatible active-fixation screw in lead with ≤7F lead introducer.

1

-

-

... More
Digital multi-programmable pacemaker pulse generator, 1.5 Tesla MRI compatible. Mode: single chamber: VVI/AAI. Pulse generator compatible with above leads (Sl. No. 4 & 5)

1

-

-

... More
Digital multi-programmable pacemaker with lifetime warranty, 3 Tesla MRI compatible with Automatic capture facility for rescue pacing and automatic lead polarity switch. Mode: single chamber: VVI/AAI. With ≤6F compatible passive-fixation tined lead with ≤7F lead introducer.

1

-

-

... More
Digital multi-programmable pacemaker with lifetime warranty, 3 Tesla MRI compatible with Automatic capture facility for rescue pacing and automatic lead polarity switch. Mode: single chamber: VVI/AAI. With ≤6F compatible active-fixation screw in lead with ≤7F lead introducer.

1

-

-

... More
Digital multi-programmable pacemaker pulse generator, 3 Tesla MRI compatible. Mode: single chamber: VVI/AAI. Pulse generator compatible with above leads (Sl. No. 7 & 8)

1

-

-

... More
Digital multi-programmable pacemaker with lifetime warranty, 1.5 Tesla MRI compatible with Automatic capture facility for rescue pacing and automatic lead polarity switch. Mode: single chamber: VVIR/AAIR. With dynamic adjustment of pacing output and proven longevity of 10 years with 100% pacing of RA/RV. Digital high sampling rate of P/R wave and automated ventricular rate stabilization during AF. With ≤6F compatible passive-fixation tined lead or screw in lead with ≤7F lead introducer.

1

-

-

... More
Pulse generator only for serial number 10.

1

-

-

... More
Digital multi-programmable pacemaker with lifetime warranty, full body 3 Tesla MRI compatible with Automatic capture facility for rescue pacing and automatic lead polarity switch. Mode: single chamber: VVIR/AAIR. With dynamic adjustment of pacing output and proven longevity of 10 years with 100% pacing of RA/RV. Digital high sampling rate of P/R wave and automated ventricular rate stabilization during AF. With ≤6F compatible passive-fixation tined lead or screw in lead with ≤7F lead introducer.

1

-

-

... More
Pulse generator only for serial number 12.

1

-

-

... More
Digital multi-programmable pacemaker with lifetime warranty Mode: Dual chamber VDD (with separate atrial and ventricular leads). With dynamic adjustment of pacing output and proven longevity of 10 years with 100% pacing of RA/RV. With advanced features like automatic AV search, to minimize RV pacing. With ≤6F compatible passive-fixation tined leads or screw in leads with ≤7F lead introducers.

1

-

-

... More
Pulse generator only for serial number 14.

1

-

-

... More
Digital multi-programmable pacemaker with lifetime warranty Mode: Dual chamber VDD (with separate atrial and ventricular leads) with 1.5 Tesla MRI compatible. With ≤6F compatible passive-fixation tined leads or screw in leads with ≤7F lead introducers.

1

-

-

... More
Pulse generator only for serial number 16.

1

-

-

... More
Digital multi-programmable pacemaker with lifetime warranty Mode: Dual chamber VDD (with separate atrial and ventricular leads) with full body 3 Tesla MRI compatible. With ≤6F compatible passive-fixation tined leads or screw in leads with ≤7F lead introducers.

1

-

-

... More
Pulse generator only for serial number 18.

1

-

-

... More
Digital multi-programmable pacemaker with lifetime warranty with Automatic capture facility for rescue pacing and automatic lead polarity switch. Mode: Dual chamber: DDD. With ≤6F compatible passive-fixation tined leads or screw in leads with ≤7F lead introducers.

1

-

-

... More
Pulse generator only for serial number 20.

1

-

-

... More
Digital multi-programmable pacemaker with lifetime warranty, 1.5 Tesla MRI compatible with Automatic capture facility for rescue pacing and automatic lead polarity switch. Mode: Dual chamber: DDD. With ≤6F compatible passive-fixation tined leads or screw in leads with ≤7F lead introducers.

1

-

-

... More
Pulse generator only for serial number 22.

1

-

-

... More
Digital multi-programmable pacemaker with lifetime warranty, full body 3 Tesla MRI compatible with Automatic capture facility for rescue pacing and automatic lead polarity switch. Mode: Dual chamber: DDD. With ≤6F compatible passive-fixation tined leads or screw in leads with ≤7F lead introducers.

1

-

-

... More
Pulse generator only for serial number 24.

1

-

-

... More
Digital multi-programmable pacemaker with lifetime warranty with Automatic capture facility for rescue pacing and automatic lead polarity switch. Mode: Dual chamber: DDDR. With features of automatic threshold check, auto adjusting of AV delay (extendable upto 400 ms), and automatic intrinsic activity search. With dynamic adjustment of pacing output and proven longevity of 10 years with 100% pacing of RA & RV and algorithm for neurocardiogenic syncope. With ≤6F compatible passive-fixation tined leads or screw in leads with ≤7F lead introducers.

1

-

-

... More
Pulse generator only for serial number 26.

1

-

-

... More
Digital multi-programmable pacemaker with lifetime warranty, 1.5 Tesla MRI compatible with Automatic capture facility for rescue pacing and automatic lead polarity switch. Mode: Dual chamber: DDDR. With features of automatic threshold check, auto adjusting of AV delay (extendable upto 400 ms), and automatic intrinsic activity search. With dynamic adjustment of pacing output and proven longevity of 10 years with 100% pacing of RA & RV and algorithm for neurocardiogenic syncope. With ≤6F compatible passive-fixation tined leads or screw in leads with ≤7F lead introducers.

1

-

-

... More
Pulse generator only for serial number 28.

1

-

-

... More
Digital multi-programmable pacemaker with lifetime warranty, full body 3 Tesla MRI compatible with Automatic capture facility for rescue pacing and automatic lead polarity switch. Mode: Dual chamber: DDDR. With features of automatic threshold check, auto adjusting of AV delay (extendable upto 400 ms), and automatic intrinsic activity search. With dynamic adjustment of pacing output and proven longevity of 10 years with 100% pacing of RA & RV and algorithm for neurocardiogenic syncope. With ≤6F compatible passive-fixation tined leads or screw in leads with ≤7F lead introducers.

1

-

-

... More
Pulse generator only for serial number 30.

1

-

-

... More
Biventricular cardiac resynchronization (CRT-P) device with bi-polar LV lead. With ≥4 vector for pacing from LV lead, having dedicated subselect catheter for cannulation of selective coronary sinus branch, having both peel-away or slittable LV lead introducer sheath. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 32 (Biventricular cardiac resynchronization (CRT-P) device with bi-polar LV lead).

1

-

-

... More
Biventricular cardiac resynchronization (CRT-P) device with bipolar LV lead, 1.5 Tesla MRI compatible. With ≥4 vector for pacing from LV lead, having dedicated subselect catheter for cannulation of selective coronary sinus branch, having both peel-away or slittable LV lead introducer sheath. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 34 (Biventricular cardiac resynchronization (CRT-P) device with bi-polar LV lead, 1.5 T MRI compatible).

1

-

-

... More
Biventricular cardiac resynchronization (CRT-P) device with bipolar LV lead, full body 3 Tesla MRI compatible. With ≥4 vector for pacing from LV lead, having dedicated subselect catheter for cannulation of selective coronary sinus branch, having both peel-away or slittable LV lead introducer sheath. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 36 (Biventricular cardiac resynchronization (CRT-P) device with bi-polar LV lead, 3 T MRI compatible).

1

-

-

... More
Biventricular cardiac resynchronization (CRT-P) device with Quadripolar LV lead. With ≥4 vector for pacing from LV lead, having dedicated subselect catheter for cannulation of selective coronary sinus branch, having both peel-away or slittable LV lead introducer sheath. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 38 (Biventricular cardiac resynchronization (CRT-P) device with Quadripolar LV lead).

1

-

-

... More
Biventricular cardiac resynchronization (CRT-P) device with Quadripolar LV lead, 1.5 Tesla MRI compatible. With ≥4 vector for pacing from LV lead, having dedicated subselect catheter for cannulation of selective coronary sinus branch, having both peel-away or slittable LV lead introducer sheath. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 40 (Biventricular cardiac resynchronization (CRT-P) device with Quadripolar LV lead, 1.5 T MRI compatible).

1

-

-

... More
Biventricular cardiac resynchronization (CRT-P) device with Quadripolar LV lead, full body 3 Tesla MRI compatible. With ≥4 vector for pacing from LV lead, having dedicated subselect catheter for cannulation of selective coronary sinus branch, having both peel-away or slittable LV lead introducer sheath. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 42 (Biventricular cardiac resynchronization (CRT-P) device with Quadripolar LV lead, 3 T MRI compatible).

1

-

-

... More
Biventricular cardiac resynchronization (CRT-P) device with epicardial LV lead. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 44 (Biventricular cardiac resynchronization (CRT-P) device with epicardial LV lead).

1

-

-

... More
Biventricular cardiac resynchronization (CRT-P) device with epicardial LV lead, 1.5 Tesla MRI compatible. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 46 (Biventricular cardiac resynchronization (CRT-P) device with epicardial LV lead, 1.5 T MRI compatible).

1

-

-

... More
Biventricular cardiac resynchronization (CRT-P) device with epicardial LV lead, full body 3 Tesla MRI compatible. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 48 (Biventricular cardiac resynchronization (CRT-P) device with epicardial LV lead, 3 T MRI compatible).

1

-

-

... More
Combo device (CRT-D) with bipolar LV lead. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 50 (Combo device (CRT-D) with bipolar LV lead.)

1

-

-

... More
Combo device (CRT-D) with bipolar LV lead. 1.5 Tesla MRI compatible. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 52 (Combo device (CRT-D) with bipolar LV lead. 1.5 Tesla MRI compatible.)

1

-

-

... More
Combo device (CRT-D) with bipolar LV lead. Full body 3 Tesla MRI compatible. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 54 (Combo device (CRT-D) with bipolar LV lead. 3 Tesla MRI compatible.)

1

-

-

... More
Combo device (CRT-D) with bipolar LV lead. Less weight (approx ≤75±5 gm.) and small volume (approx ≤30±6 cc), possibility of ≥5 pacing vectors with bipolar LV lead. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 56.

1

-

-

... More
Combo device (CRT-D) with bipolar LV lead, 1.5 Tesla MRI compatible. Less weight (approx ≤75±5 gm.) and small volume (approx ≤30±6 cc), possibility of ≥5 pacing vectors with bipolar LV lead. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 58

1

-

-

... More
Combo device (CRT-D) with bipolar LV lead, full body 3 Tesla MRI compatible. Less weight (approx ≤75±5 gm.) and small volume (approx ≤30±6 cc), possibility of ≥5 pacing vectors with bipolar LV lead. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 60

1

-

-

... More
Combo device (CRT-D) with Quadripolar LV lead. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 62 (Combo device (CRT-D) with Quadripolar LV lead.)

1

-

-

... More
Combo device (CRT-D) with Quadripolar LV lead. 1.5 Tesla MRI compatible. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 64 (Combo device (CRT-D) with Quadripolar LV lead. 1.5 Tesla MRI compatible.)

1

-

-

... More
Combo device (CRT-D) with Quadripolar LV lead. Full body 3 Tesla MRI compatible. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 66 (Combo device (CRT-D) with Quadripolar LV lead. 3 Tesla MRI compatible.)

1

-

-

... More
Combo device (CRT-D) with Quadripolar LV lead. Less weight (approx ≤75±5 gm.) and small volume (approx ≤30±6 cc), possibility of ≥10 pacing vectors with the Quadripolar LV lead. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 68

1

-

-

... More
Combo device (CRT-D) with Quadripolar LV lead, 1.5 Tesla MRI compatible. Less weight (approx ≤75±5 gm.) and small volume (approx ≤30±6 cc), possibility of ≥10 pacing vectors with the Quadripolar LV lead. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 70

1

-

-

... More
Combo device (CRT-D) with Quadripolar LV lead, full body 3 Tesla MRI compatible. Less weight (approx ≤75±5 gm.) and small volume (approx ≤30±6 cc), possibility of ≥10 pacing vectors with the Quadripolar LV lead. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 72

1

-

-

... More
Combo device (CRT-D) with Quadripolar LV lead. Less weight (approx ≤75±5 gm.) and small volume (approx ≤30±6 cc), possibility of ≥15 pacing vectors with the Quadripolar LV lead. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 74

1

-

-

... More
Combo device (CRT-D) with Quadripolar LV lead, 1.5 Tesla MRI compatible. Less weight (approx ≤75±5 gm.) and small volume (approx ≤30±6 cc), possibility of ≥15 pacing vectors with the Quadripolar LV lead. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 76

1

-

-

... More
Combo device (CRT-D) with Quadripolar LV lead, full body 3 Tesla MRI compatible. Less weight (approx ≤75±5 gm.) and small volume (approx ≤30±6 cc), possibility of ≥15 pacing vectors with the Quadripolar LV lead. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 78

1

-

-

... More
Combo device (CRT-D) with bipolar LV lead, with DF-4 connector of RV lead. Less weight (approx ≤75±5 gm.) and small volume (approx ≤30±6 cc), possibility of ≥3 pacing vectors with bipolar LV lead. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 80

1

-

-

... More
Combo device (CRT-D) with bipolar LV lead, DF-4 connector of RV lead, 1.5 Tesla MRI compatible. Less weight (approx ≤75±5 gm.) and small volume (approx ≤30±6 cc), possibility of ≥3 pacing vectors with bipolar LV lead. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 82

1

-

-

... More
Combo device (CRT-D) with bipolar LV lead, DF-4 connector of RV lead, full body 3 Tesla MRI compatible. Less weight (approx ≤75±5 gm.) and small volume (approx ≤30±6 cc), possibility of ≥3 pacing vectors with bipolar LV lead. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 84

1

-

-

... More
Combo device (CRT-D) with bipolar LV lead, with DF-4 connector of RV lead. Less weight (approx ≤75±5 gm.) and small volume (approx ≤30±6 cc), possibility of ≥5 pacing vectors with bipolar LV lead. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 86

1

-

-

... More
Combo device (CRT-D) with bipolar LV lead, DF-4 connector of RV lead, 1.5 Tesla MRI compatible. Less weight (approx ≤75±5 gm.) and small volume (approx ≤30±6 cc), possibility of ≥5 pacing vectors with bipolar LV lead. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 88

1

-

-

... More
Combo device (CRT-D) with bipolar LV lead, DF-4 connector of RV lead, full body 3 Tesla MRI compatible. Less weight (approx ≤75±5 gm.) and small volume (approx ≤30±6 cc), possibility of ≥5 pacing vectors with bipolar LV lead. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 90

1

-

-

... More
Combo device (CRT-D) with Quadripolar LV lead, DF-4 connector of RV lead. Less weight (approx ≤75±5 gm.) and small volume (approx ≤30±6 cc), with possibility of ≥10 pacing vectors with Quadripolar LV lead. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 92

1

-

-

... More
Combo device (CRT-D) with Quadripolar LV lead, DF-4 connector of RV lead, 1.5 Tesla MRI compatible. Less weight (approx ≤75±5 gm.) and small volume (approx ≤30±6 cc), with possibility of ≥10 pacing vectors with Quadripolar LV lead. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 94

1

-

-

... More
Combo device (CRT-D) with Quadripolar LV lead, DF-4 connector of RV lead, full body 3T MRI compatible. Less weight (approx ≤75±5 gm.) and small volume (approx ≤30±6 cc), with possibility of ≥10 pacing vectors with Quadripolar LV lead. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 96

1

-

-

... More
Combo device (CRT-D) with Quadripolar LV lead, DF-4 connector of RV lead. Less weight (approx ≤75±5 gm.) and small volume (approx ≤30±6 cc), with possibility of ≥15 pacing vectors with Quadripolar LV lead. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 98

1

-

-

... More
Combo device (CRT-D) with Quadripolar LV lead, DF-4 connector of RV lead, 1.5 Tesla MRI compatible. Less weight (approx ≤75±5 gm.) and small volume (approx ≤30±6 cc), with possibility of ≥15 pacing vectors with Quadripolar LV lead. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 100

1

-

-

... More
Combo device (CRT-D) with Quadripolar LV lead, DF-4 connector of RV lead, full body 3T MRI compatible. Less weight (approx ≤75±5 gm.) and small volume (approx ≤30±6 cc), with possibility of ≥15 pacing vectors with Quadripolar LV lead. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 102

1

-

-

... More
Combo device (CRT-D) with epicardial LV lead. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 104

1

-

-

... More
Combo device (CRT-D) with epicardial LV lead, 1.5 Tesla MRI compatible. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 106

1

-

-

... More
Combo device (CRT-D) with epicardial LV lead, full body 3T MRI compatible. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 108

1

-

-

... More
Implantable cardioverter defibrillator: Single chamber. Device with lead (passive tined or active screwing)

1

-

-

... More
Pulse generator for serial no. 110 (Implantable cardioverter defibrillator: Single chamber.)

1

-

-

... More
Implantable cardioverter defibrillator: Single chamber, 1.5 Tesla MRI compatible. Device with lead (passive tined or active screwing)

1

-

-

... More
Pulse generator for serial no. 112 (Implantable cardioverter defibrillator: Single chamber, 1.5 T MRI compatible.)

1

-

-

... More
Implantable cardioverter defibrillator: Single chamber, full body 3T MRI compatible. Device with lead (passive tined or active screwing)

1

-

-

... More
Pulse generator for serial no. 114 (Implantable cardioverter defibrillator: Single chamber, 3 T MRI compatible.)

1

-

-

... More
Implantable cardioverter defibrillator: Single chamber with DF-4 header. Device with lead (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 116 (Implantable cardioverter defibrillator: Single chamber with DF-4 header)

1

-

-

... More
Implantable cardioverter defibrillator: Single chamber with DF-4 header, 1.5 Tesla MRI compatible. Device with lead (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 118 (Implantable cardioverter defibrillator: Single chamber with DF-4 header, 1.5 T MRI compatible.)

1

-

-

... More
Implantable cardioverter defibrillator: Single chamber with DF-4 header, full body 3T MRI compatible. Device with lead (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 120 (Implantable cardioverter defibrillator: Single chamber with DF-4 header, 3 T MRI compatible.)

1

-

-

... More
Implantable cardioverter defibrillator: Dual chamber. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 122 (Implantable cardioverter defibrillator: Dual chamber.)

1

-

-

... More
Implantable cardioverter defibrillator: Dual chamber, 1.5 Tesla MRI compatible. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 124 (Implantable cardioverter defibrillator: Dual chamber, 1.5 T MRI compatible.)

1

-

-

... More
Implantable cardioverter defibrillator: Dual chamber, full body 3 Tesla MRI compatible. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 126 (Implantable cardioverter defibrillator: Dual chamber, 3 T MRI compatible.)

1

-

-

... More
Implantable cardioverter defibrillator: Dual chamber. Less weight (approx ≤60±5 gm.) and small volume (approx ≤25±5 cc) with advanced features of automatic AV search, adjustable AV delay etc. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 128

1

-

-

... More
Implantable cardioverter defibrillator: Dual chamber, 1.5 Tesla MRI compatible. Less weight (approx ≤60±5 gm.) and small volume (approx ≤25±5 cc) with advanced features of automatic AV search, adjustable AV delay etc. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 130

1

-

-

... More
Implantable cardioverter defibrillator: Dual chamber, full body 3 Tesla MRI compatible. Less weight (approx ≤60±5 gm.) and small volume (approx ≤25±5 cc) with advanced features of automatic AV search, adjustable AV delay etc. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 132

1

-

-

... More
Implantable cardioverter defibrillator: Dual chamber with DF-4 header. Less weight (approx ≤60±5 gm.) and small volume (approx ≤25±5 cc) with advanced features of automatic AV search, adjustable AV delay etc. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 134

1

-

-

... More
Implantable cardioverter defibrillator: Dual chamber with DF-4 header, with 1.5 Tesla MRI compatible. Less weight (approx ≤60±5 gm.) and small volume (approx ≤25±5 cc) with advanced features of automatic AV search, adjustable AV delay etc. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 136

1

-

-

... More
Implantable cardioverter defibrillator: Dual chamber with DF-4 header, with full body 3 Tesla MRI compatible. Less weight (approx ≤60±5 gm.) and small volume (approx ≤25±5 cc) with advanced features of automatic AV search, adjustable AV delay etc. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 138

1

-

-

... More
Subcutaneous ICD. Device with lead and all accessories for implantation

1

-

-

... More
Pulse generator for serial no. 140

1

-

-

... More
MRI compatible subcutaneous ICD. Device with lead and all accessories for implantation

1

-

-

... More
Pulse generator for serial no. 142

1

-

-

... More
Permanent pacing lead (ventricular/atrial endocardial bipolar, passive fixation with tines), steroid eluting, IS-1 header with the introducer sheath and puncture set (PLI).

1

-

-

... More
1.5 Tesla MRI compatible permanent pacing lead (ventricular/atrial endocardial bipolar, passive fixation with tines), steroid eluting, IS-1 header with the introducer sheath and puncture set (PLI).

1

-

-

... More
3 Tesla full body MRI compatible permanent pacing lead (ventricular/atrial endocardial bipolar, passive fixation with tines), steroid eluting, IS-1 header with the introducer sheath and puncture set (PLI).

1

-

-

... More
Permanent pacing lead (ventricular/atrial endocardial bipolar, active fixation steroid eluting screw in lead) with IS-1 header with the introducer sheath and puncture set (PLI).

1

-

-

... More
1.5 Tesla MRI compatible permanent pacing lead (ventricular/atrial endocardial bipolar, active fixation steroid eluting screw in lead) with IS-1 header with the introducer sheath and puncture set (PLI).

1

-

-

... More
3 Tesla full body MRI compatible permanent pacing lead (ventricular/atrial endocardial bipolar, active fixation steroid eluting screw in lead) with IS-1 header with the introducer sheath and puncture set (PLI).

1

-

-

... More
Unipolar, MRI compatible, epicardial permanent screw-in pacing lead, steroid eluting, IS-1 header with the deploying kit and introducer set.

1

-

-

... More
Bipolar, MRI compatible, epicardial permanent screw-in pacing lead, steroid eluting, IS-1 header with the deploying kit.

1

-

-

... More
Unipolar, epicardial permanent screw-in pacing lead, steroid eluting, IS-1 header with the deploying kit and introducer set.

1

-

-

... More
Bipolar, epicardial permanent screw-in pacing lead, steroid eluting, IS-1 header with the deploying kit.

1

-

-

... More
MRI compatible short (45±3 cm) endocardial bipolar pacing lead with introducer sheath and puncture set (PLI).

1

-

-

... More
Only introducer kit for endocardial RA/RV/ICD leads (without leads), 6F, 7F, 8F.

1

-

-

... More
Permanent defibrillation lead, bipolar, endocardial steroid eluting tipped, DF-1 header, with the introducer kit and puncture set (PLI). Tined end

1

-

-

... More
Permanent defibrillation lead, bipolar, endocardial steroid eluting tipped, DF-1 header, with the introducer kit and puncture set (PLI). Screw in lead

1

-

-

... More
Permanent defibrillation lead, bipolar, endocardial steroid eluting leads, DF-1 header, with the introducer sheath and puncture set (PLI). 1.5 Tesla full body MRI compatible. Tined lead

1

-

-

... More
Permanent defibrillation lead, bipolar, endocardial steroid eluting leads, DF-1 header, with the introducer sheath and puncture set (PLI). 1.5 Tesla full body MRI compatible. Screw lead

1

-

-

... More
Permanent defibrillation lead, bipolar, endocardial steroid eluting leads, DF-1 header, with the introducer sheath and puncture set (PLI). 3 Tesla full body MRI compatible. Tined lead

1

-

-

... More
Permanent defibrillation lead, bipolar, endocardial steroid eluting leads, DF-1 header, with the introducer sheath and puncture set (PLI). 3 Tesla full body MRI compatible. Screw lead

1

-

-

... More
Permanent defibrillation lead, bipolar, endocardial steroid eluting tipped, with DF-4 header, with the introducer kit and puncture set (PLI). Tined end

1

-

-

... More
Permanent defibrillation lead, bipolar, endocardial steroid eluting tipped, with DF-4 header, with the introducer kit and puncture set (PLI). Screw end

1

-

-

... More
Permanent defibrillation lead, bipolar, endocardial steroid eluting tipped, DF-4 header, with the introducer kit and puncture set (PLI), 1.5 Tesla MRI compatible. Tined end

1

-

-

... More
Permanent defibrillation lead, bipolar, endocardial steroid eluting tipped, DF-4 header, with the introducer kit and puncture set (PLI), 1.5 Tesla MRI compatible. Screw end

1

-

-

... More
Permanent defibrillation lead, bipolar, endocardial steroid eluting tipped, DF-4 header, with the introducer kit and puncture set (PLI), full body 3 Tesla MRI compatible. Tined end

1

-

-

... More
Permanent defibrillation lead, bipolar, endocardial steroid eluting tipped, DF-4 header, with the introducer kit and puncture set (PLI), full body 3 Tesla MRI compatible. Screw end

1

-

-

... More
Bipolar endocardial LV lead with introducer kit and puncture set (PLI).

1

-

-

... More
Bipolar endocardial LV lead with introducer kit and puncture set (PLI), 1.5 Tesla MRI compatible.

1

-

-

... More
Bipolar endocardial LV lead with introducer kit and puncture set (PLI), full body 3 Tesla MRI compatible.

1

-

-

... More
Quadripolar endocardial LV lead with introducer kit and puncture set (PLI).

1

-

-

... More
Quadripolar endocardial LV lead with introducer kit and puncture set (PLI), 1.5 Tesla MRI compatible.

1

-

-

... More
Quadripolar endocardial LV lead with introducer kit and puncture set (PLI), full body 3 Tesla MRI compatible.

1

-

-

... More
Quadripolar endocardial LV lead for multisite pacing with introducer kit and puncture set (PLI), full body 3 Tesla MRI compatible.

1

-

-

... More
CS cannulation kit only (without the LV lead) with all accessories like sheath, puncture needle, syringe, 0.035” long guidewire.

1

-

-

... More
External event recording of upto one week of arrhythmic events, portable, easy to operate with 1/3 lead system and easy operation by patient/relatives at home.

1

-

-

... More
Patch type External event recorder, disposable, wireless, easy to use smart biosensor, shower-proof for recording upto one week of arrhythmic events, and easy operation by patient/relatives at home.

1

-

-

... More
Implantable event/loop recorder for recording of arrhythmic events for prolong period of upto 2 years.

1

-

-

... More
Digital multi-programmable pacemaker with features of automatic detection of MRI and conditioning whenever the device/patient comes to an MRI environment or MR room for MRI and with automatic timeout feature, bringing back the normal settings whenever the set window period is over. Mode: VVIR Device with lead and all accessories

1

-

-

... More
Pulse generator for serial no. 179

1

-

-

... More
Digital multi-programmable pacemaker with features of automatic detection of MRI and conditioning whenever the device/patient comes to an MRI environment or MR room for MRI and with automatic timeout feature, bringing back the normal settings whenever the set window period is over. Mode: DDDR Device with leads and all accessories

1

-

-

... More
Pulse generator for serial no. 181

1

-

-

... More
CRT-D with features of automatic detection of MRI and conditioning whenever the device/patient comes to an MRI environment or MR room for MRI and with automatic timeout feature, bringing back the normal settings whenever the set window period is over. Mode: CRT-D with bipolar LV lead Device with leads and all accessories

1

-

-

... More
Pulse generator for serial no. 183

1

-

-

... More
CRT-D with features of automatic detection of MRI and conditioning whenever the device comes to an MRI environment or MR room for MRI and with automatic timeout feature, bringing back the normal settings whenever the set window period is over. Mode: CRT-D with Quadripolar LV lead Device with leads and all accessories

1

-

-

... More
Pulse generator for serial no. 185

1

-

-

... More
Single chamber ICD with features of automatic detection of MRI and conditioning whenever the device comes to an MRI environment or MR room for MRI and with automatic timeout feature, bringing back the normal settings whenever the set window period is over. Mode: ICD (single chamber) Device with leads and all accessories

1

-

-

... More
Pulse generator for serial no. 187

1

-

-

... More
Dual chamber ICD with features of automatic detection of MRI and conditioning whenever the device comes to an MRI environment or MR room for MRI and with automatic timeout feature, bringing back the normal settings whenever the set window period is over. Mode: ICD (Dual chamber) Device with leads and all accessories

1

-

-

... More
Pulse generator for serial no. 189

1

-

-

... More
Combo device (CRT-D) with Quadripolar LV lead having features of multi-site pacing from LV lead. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 191

1

-

-

... More
Combo device (CRT-D) with Quadripolar LV lead having features of multi-site pacing from LV lead, 1.5 Tesla MRI compatible. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 193

1

-

-

... More
Combo device (CRT-D) with Quadripolar LV lead having features of multi-site pacing from LV lead, full body 3 Tesla MRI compatible. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 195

1

-

-

... More
Combo device (CRT-D) with Quadripolar LV lead having features of multi-site pacing from LV lead. DF-4 RV lead. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 197

1

-

-

... More
Combo device (CRT-D) with Quadripolar LV lead having features of multi-site pacing from LV lead, DF-4 RV lead, 1.5 Tesla MRI compatible. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 199

1

-

-

... More
Combo device (CRT-D) with Quadripolar LV lead having features of multi-site pacing from LV lead, DF-4 RV lead, 3 Tesla full body MRI compatible. Less weight (approx ≤75±5 gm.) and small volume (approx ≤30±6 cc). Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 201

1

-

-

... More
Digital multi-programmable pacemaker with limited warranty for 10 years. Mode: single chamber: VVI/AAI. With dynamic adjustment of pacing output. Digital high sampling rate of P/R wave and automated ventricular rate stabilization during AF and with Automatic capture facility for rescue pacing and automatic lead polarity switch. With ≤6F compatible passive-fixation tined lead or screw in lead with ≤7F lead introducer.

1

-

-

... More
Pulse generator for serial no. 203

1

-

-

... More
Digital multi-programmable pacemaker with limited warranty for 10 years, 1.5 Tesla MRI compatible. Mode: single chamber: VVI/AAI. With dynamic adjustment of pacing output. Digital high sampling rate of P/R wave and automated ventricular rate stabilization during AF and with Automatic capture facility for rescue pacing and automatic lead polarity switch. With ≤6F compatible passive-fixation tined lead or screw in lead with ≤7F lead introducer.

1

-

-

... More
Pulse generator for serial no. 205

1

-

-

... More
Digital multi-programmable pacemaker with limited warranty for 10 years, full body 3 Tesla MRI compatible. Mode: single chamber: VVI/AAI. With dynamic adjustment of pacing output. Digital high sampling rate of P/R wave and automated ventricular rate stabilization during AF and with Automatic capture facility for rescue pacing and automatic lead polarity switch. With ≤6F compatible passive-fixation tined lead or screw in lead with ≤7F lead introducer.

1

-

-

... More
Pulse generator for serial no. 207

1

-

-

... More
Digital multi-programmable pacemaker with limited warranty for 10 years. Mode: single chamber: VVIR/AAIR. With dynamic adjustment of pacing output. Digital high sampling rate of P/R wave and automated ventricular rate stabilization during AF and with Automatic capture facility for rescue pacing and automatic lead polarity switch. With ≤6F compatible passive-fixation tined lead or screw in lead with ≤7F lead introducer.

1

-

-

... More
Pulse generator for serial no. 209

1

-

-

... More
Digital multi-programmable pacemaker with limited warranty for 10 years, 1.5 Tesla MRI compatible. Mode: single chamber: VVIR/AAIR. With dynamic adjustment of pacing output. Digital high sampling rate of P/R wave and automated ventricular rate stabilization during AF and with Automatic capture facility for rescue pacing and automatic lead polarity switch. With ≤6F compatible passive-fixation tined lead or screw in lead with ≤7F lead introducer.

1

-

-

... More
Pulse generator for serial no. 211

1

-

-

... More
Digital multi-programmable pacemaker with limited warranty for 10 years, full body 3 Tesla MRI compatible. Mode: single chamber: VVIR/AAIR. With dynamic adjustment of pacing output. Digital high sampling rate of P/R wave and automated ventricular rate stabilization during AFand with Automatic capture facility for rescue pacing and automatic lead polarity switch. With ≤6F compatible passive-fixation tined lead or screw in lead with ≤7F lead introducer.

1

-

-

... More
Pulse generator for serial no. 213

1

-

-

... More
Digital multi-programmable pacemaker with lifetime warranty. Mode: Dual chamber: DDDR. With features of automatic threshold check, auto adjusting of AV delay (extendable upto 400 ms), automatic intrinsic activity search, and ATP. With dynamic adjustment of pacing output and proven longevity of 10 years with 100% pacing of RA & RV and with Automatic capture facility for rescue pacing and automatic lead polarity switch. With ≤6F compatible passive-fixation tined leads or screw in leads with ≤7F lead introducers.

1

-

-

... More
Pulse generator for serial no. 215

1

-

-

... More
Digital multi-programmable pacemaker with lifetime warranty. Mode: Dual chamber: DDDR. With features of automatic threshold check, auto adjusting of AV delay (extendable upto 400 ms), automatic intrinsic activity search, and ATP. With dynamic adjustment of pacing output and proven longevity of 10 years with 100% pacing of RA & RV. 1.5 Tesla MRI compatible and with Automatic capture facility for rescue pacing and automatic lead polarity switch. With ≤6F compatible passive-fixation tined leads or screw in leads with ≤7F lead introducers.

1

-

-

... More
Pulse generator for serial no. 217

1

-

-

... More
Digital multi-programmable pacemaker with lifetime warranty. Mode: Dual chamber: DDDR. With features of automatic threshold check, auto adjusting of AV delay (extendable upto 400 ms), automatic intrinsic activity search, and ATP. With dynamic adjustment of pacing output and proven longevity of 10 years with 100% pacing of RA & RV and with Automatic capture facility for rescue pacing and automatic lead polarity switch. Full body 3 Tesla MRI compatible. With ≤6F compatible passive-fixation tined leads or screw in leads with ≤7F lead introducers.

1

-

-

... More
Pulse generator for serial no. 219

1

-

-

... More
Digital multi-programmable pacemaker with lifetime warranty with Automatic capture facility for rescue pacing and automatic lead polarity switch. Mode: Dual chamber: DDDR. With features of automatic threshold check, auto adjusting of AV delay (extendable upto 400 ms), and automatic intrinsic activity search. With dynamic adjustment of pacing output and proven longevity of 10 years with 100% pacing of RA & RV and with closed loop stimulation. With ≤6F compatible passive-fixation tined leads or screw in leads with ≤7F lead introducers.

1

-

-

... More
Pulse generator for serial no.221

1

-

-

... More
Digital multi-programmable pacemaker with lifetime warranty with Automatic capture facility for rescue pacing and automatic lead polarity switch. Mode: Dual chamber: DDDR. With features of automatic threshold check, auto adjusting of AV delay (extendable upto 400 ms), and automatic intrinsic activity search. With dynamic adjustment of pacing output and proven longevity of 10 years with 100% pacing of RA & RV and with minute ventilation sensor. With ≤6F compatible passive-fixation tined leads or screw in leads with ≤7F lead introducers.

1

-

-

... More
Pulse generator for serial no.223

1

-

-

... More
Implantable cardioverter defibrillator: VDD with single lead. Device with lead (passive tined or active screwing) and introducer set.

1

-

-

... More
Pulse generator for serial no. 225

1

-

-

... More
Implantable cardioverter defibrillator: VDD with single lead, 1.5 Tesla MRI compatible. Device with lead (passive tined or active screwing) and introducer set.

1

-

-

... More
Pulse generator for serial no. 227

1

-

-

... More
Implantable cardioverter defibrillator: VDD with single lead, full body 3 Tesla MRI compatible. Device with lead (passive tined or active screwing) and introducer set.

1

-

-

... More
Pulse generator for serial no. 229

1

-

-

... More
MRI compatible Leadless pacemaker with all accessories for implantation. VVIR type.

1

-

-

... More
3 Tesla & / 1.5 Tesla full body MRI conditional Multi-programmable, Quadripolar lead, auto capture management for RA,RV & LV, Automatic atrial anti tachy therapies, Heart failure diagnostics with trans thoracic fluid impedance measurement and rate drop response, multi-site/multipoint pacing CRT-P.

1

-

-

... More
Pulse generator for serial no. 232

1

-

-

... More
3 Tesla & / 1.5 Tesla full body MRI conditional Multi-programmable, Quadripolar lead, auto capture management for RA,RV & LV, Automatic atrial anti tachy therapies, Heart failure diagnostics with trans thoracic fluid impedance measurement and rate drop response, multi-site/multipoint pacing CRT-D.

1

-

-

... More
Pulse generator for serial no. 234

1

-

-

... More
DDDR pacemaker with rate response, AF diagnostic and heart failure management.

1

-

-

... More
Pulse generator for serial no. 236

1

-

-

... More
3.0 Tesla DDDR pacemaker with auto rate response, AF diagnostic and heart failure management.

1

-

-

... More
Pulse generator for serial no. 238

1

-

-

... More
His bundle pacing system A) Complete system with leads B) IPG only C) His bundle lead only

1

-

-

... More
Pulse generator for serial no. 240

1

-

-

... More
3 Tesla MRI compatible His bundle pacing system A) Complete system with leads B) IPG only C) His bundle lead only

1

-

-

... More
Pulse generator for serial no. 242

1

-

-

... More
Adaptor for old pacing lead to IS-I Compatible

1

-

-

... More
Latex free compression set with soft material for pacemaker/ICD implantation after care.

1

-

-

... More
Implantable cardioverter defibrillator: Single chamber. With 8 years full warranty plus 2 years warranty on pro-rata basis. Device with lead (passive tined or active screwing) and introducer set.

1

-

-

... More
Pulse generator for serial no. 246

1

-

-

... More
Implantable cardioverter defibrillator: Single chamber, 3 Tesla MRI compatible. With 8 years full warranty plus 2 years warranty on pro-rata basis. Device with lead (passive tined or active screwing) and introducer set.

1

-

-

... More
Pulse generator for serial no. 248

1

-

-

... More
Implantable cardioverter defibrillator: Dual chamber with 5 years full warranty plus 3 years warranty on pro-rata basis. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 250

1

-

-

... More
Implantable cardioverter defibrillator: Dual chamber, 3 Tesla MRI compatible. With 5 years full warranty plus 3 years warranty on pro-rata basis.Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 252

1

-

-

... More
Combo device (CRT-D) with Quadripolar LV lead, with 4 years full warranty plus 2 years warranty on pro-rata basis. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 254

1

-

-

... More
Combo device (CRT-D) with Quadripolar LV lead, with 4 years full warranty plus 2 years warranty on pro-rata basis. 3 Tesla MRI compatible. Device with all leads (passive tined or active screwing) and introducers.

1

-

-

... More
Pulse generator for serial no. 256

1

-

-

... More
MRI compatible AV Leadless pacemaker (AV Micra) with all accessories for implantation.

1

-

-

... More
His Bundle DDDR Pacemaker. (a.)Multi-programmable Dual Chamber Rate Responsive Full Body 3 T MRI Compatible Pacemaker. (b.) Atrial Endocardial Leads both Active and Passive Fixation IS-1 Bipolar and Unipolar as per Clinical Need. (c.) HIS Bundle with Lumen Pacing Lead with Catheter and all accessories (c.) Auto Capture Output Management Software for battery Optimization. (d.) Lead Polarity Switch (e.) With 8 year Warranty Replacement Policy. (f) automatic detection of MRI and conditioning whenever the device/patient comes to an MRI environment or MR room for MRI and with automatic timeout feature, bringing back the normal settings whenever the set window period is over.

1

-

-

... More
Pulse generator for serial no. 259

1

-

-

... More
His Bundle DDDR Pacemaker with lifetime warranty. (a.)Multi-programmable Dual Chamber Rate Responsive Full Body 3 Tesla MRI Compatible Pacemaker. (b.) Atrial Endocardial Leads both Active and Passive Fixation IS-1 Bipolar and Unipolar as per Clinical Need. (c.) HIS Bundle with Lumen Pacing Lead with Catheter and all accessories (c.) Auto Capture Output Management Software for battery Optimization. (d.) Lead Polarity Switch (e) automatic detection of MRI and conditioning whenever the device/patient comes to an MRI environment or MR room for MRI and with automatic timeout feature, bringing back the normal settings whenever the set window period is over.

1

-

-

... More
Pulse generator for serial no. 261

1

-

-

... More
His Bundle DDDR Pacemaker: Dual Chamber Rate Responsive 3 T Full body MRI compatible Pacemaker with HIS Bundle Lumen Lead and Delivery System with features of automatic detection of MRI and conditioning whenever the device/patient comes to an MRI environment or MR room for MRI and with automatic timeout feature, bringing back the normal settings whenever the set window period is over. (a.) HIS Bundle Screwing Lead with Lumen (b.) With Delivery Catheter.

1

-

-

... More
Pulse generator for serial no. 263

1

-

-

... More
His Bundle DDDR Pacemaker. (a.)Multi-programmable Dual Chamber Rate Responsive Full Body 3 T MRI Compatible Pacemaker. (b.) Atrial Endocardial Leads both Active and Passive Fixation IS-1 Bipolar and Unipolar as per Clinical Need. (c.) HIS Bundle with Lumenless Pacing Lead with Catheter and all accessories (c.) Auto Capture Output Management Software for battery Optimization. (d.) Lead Polarity Switch (e.) With 8 year Warranty Replacement Policy. (f) automatic detection of MRI and conditioning whenever the device/patient comes to an MRI environment or MR room for MRI and with automatic timeout feature, bringing back the normal settings whenever the set window period is over.

1

-

-

... More
Pulse generator for serial no. 265

1

-

-

... More
His Bundle DDDR Pacemaker with lifetime warranty. (a.)Multi-programmable Dual Chamber Rate Responsive Full Body 3 Tesla MRI Compatible Pacemaker. (b.) Atrial Endocardial Leads both Active and Passive Fixation IS-1 Bipolar and Unipolar as per Clinical Need. (c.) HIS Bundle with Lumenless Pacing Lead with Catheter and all accessories (c.) Auto Capture Output Management Software for battery Optimization. (d.) Lead Polarity Switch (e) automatic detection of MRI and conditioning whenever the device/patient comes to an MRI environment or MR room for MRI and with automatic timeout feature, bringing back the normal settings whenever the set window period is over.

1

-

-

... More
Pulse generator for serial no. 267

1

-

-

... More
His Bundle DDDR Pacemaker: Dual Chamber Rate Responsive 3 T Full body MRI compatible Pacemaker with HIS Bundle Lumenless Lead and Delivery System with features of automatic detection of MRI and conditioning whenever the device/patient comes to an MRI environment or MR room for MRI and with automatic timeout feature, bringing back the normal settings whenever the set window period is over. (a.) HIS Bundle Screwing Lead without Lumen (b.) With Delivery Catheter.

1

-

-

... More
Pulse generator for serial no. 269

1

-

-

... More
CRTD with Quadripolar LV Lead, DF4 defib with option of pacing in left ventricle simultaneous at two sites with Heart failure monitoring system with Bluetooth Smartphone connectivity for better patient outcome, 3T full body.

1

-

-

... More
Pulse generator for serial no. 271

1

-

-

... More
ICD Single chamber with DF4 header, Full body 3T MRI compatible with, Bluetooth Smartphone connectivity with better patient outcome

1

-

-

... More
Pulse generator for serial no. 273

1

-

-

... More
ICD dual chamber with DF4 header, Full body 3T MRI compatible with, Bluetooth Smartphone connectivity with better patient outcome.

1

-

-

... More
Pulse generator for serial no. 275

1

-

-

... More
Digital multiprogramable pacemaker with lifetime warranty and 3T full body MRI Mode: Dual Chamber, DDDR With Autocapture management and Rate responsive feature with MV Sensor with 6F Passive and active fixation lead with lead introducer

1

-

-

... More
Pulse generator for serial no. 277

1

-

-

... More
Digital multiprogramable pacemaker with lifetime warranty and 3T full body MRI Mode: Dual Chamber, DDDR with Autocapture management and Rate Responsive feature with MV Sensor and Sleep Apnea Diagnostic with 6F Passive and active fixation lead with lead introducer

1

-

-

... More
Pulse generator for serial no. 279

1

-

-

... More
Combo Device (CRT-D) with Quadripolar LV lead and DF-4 RV lead 1.5T full body MRI Conditional ≥17 pacing vectors in LV lead, Rate Responsive feature with MV Sensor with Sleep Apnea diagnostic Device with all leads (Passive and active fixation) and accessories

1

-

-

... More
Pulse generator for serial no. 281

1

-

-

... More
Absorbable anti bacterial envelope for CIED stabilization and infection reduction

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.