If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Delhi University - DU Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date3 Apr 2025
Closing Soon30 Apr 2025
Tender AmountRefer Documents
Costs
EMD
₹ 1,20,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Tender For Supply, Replacement, Installation, Testing And Commissioning Of Vrv And Vrf Type Air Conditioning System For Library And Conference Hall
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_DU_855446_1Tender No
MAC/NIT/VRF/2024/02Tender Authority
Delhi University ViewPurchaser Address
-Website
http://http://www.du.ac.in/du/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Tender for Supply, Replacement, Installation, Testing and Commissioning of VRV and VRF Type Air Conditioning System for Library and Conference Hall
Tender for Supply, Replacement, Installation, Testing and Commissioning of VRV and VRF Type Air Conditioning System for Library and Conference Hall
Tender for Supply, Replacement, Installation, Testing and Commissioning of VRV and VRF Type Air Conditioning System for Library and Conference Hall
BOQ Items
... More
Supplying, replacement, installation, testing & commissioning of different types Indoor units Nominal capacity working on R-410A refrigerant gas including mounting arrangements supports, dash fasteners complete with all accessories to be connected with existing different size refrigerant pipe as per detail below
1
-
-
... More
a) 2.0 TR, walll mounted high wall units complete with Cross flow fan, motor, cooling coil fittings etc.
2
-
-
... More
Supplying, installation, testing & Commissioning of Refrigerant 'Y' Joint with insulation required for distribution of refrigerant in copper piping etc. complete as reqd
4
-
-
... More
Providing & fixing Cordless remote for above capacities of cassette units
4
-
-
... More
Supplying & Installation and interconnecting of following size of refrigerant copper pipe work with fitting duly insulated with 19/13 mm thick closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specification all piping inside the room shall be properly supported with M.S. hanger/ angles/clamping arrangement, dash fasteners suitably run on existing cable tray etc. as reqd
1
-
-
... More
a) 6.40 mm (0.250 inches) dia (20 SWG thick) with 13mm thick nitrile rubber insulation
5
-
-
... More
b) 9.53 mm (0.375 inches) dia (20 SWG thick) with 13mm thick nitrile rubber insulation
5
-
-
... More
c) 12.7 mm (0.50 inches) dia (20 SWG thick) with 13mm thick nitrile rubber insulation
5
-
-
... More
d) 15.86 mm (0.625 inches) dia (20 SWG thick) with 13mm thick nitrile rubber insulation
5
-
-
... More
e) 19.1 mm (0.750 inches) dia (20 SWG thick) with 13mm thick nitrile rubber insulation
5
-
-
... More
e) 19.1 mm (0.750 inches) dia (20 SWG thick) with 13mm thick nitrile rubber insulation
5
-
-
... More
f) 22.2mm (0.875 inches) dia (18 SWG thick) with 19mm thick nitrile rubber insulation
5
-
-
... More
g) 28.6 mm (1 1/8 inches) dia (18 SWG thick) with 19mm thick nitrile rubber insulation
5
-
-
... More
h) 34.1 mm (1 1/8 inches) dia (18 SWG thick) with 19mm thick nitrile rubber insulation
5
-
-
... More
i) 41.3 mm (1 1/8 inches) dia (18 SWG thick) with 19mm thick nitrile rubber insulation
5
-
-
... More
Providing & fixing of Rigid UPVC pipe complete with fittings, supports as per specifications and duly insulated with 6 mm thickness of closed cell nitrile rubber insulation in surface/recess i/c cutting the wall in case of recess making good the same etc. as reqd
1
-
-
... More
a) 32 MM
40
-
-
... More
b) 25 MM
30
-
-
... More
Supplying and installing following size of perforated painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required
1
-
-
... More
a) 200 mm width x 75 mm depth x 1.6 mm thickness
40
-
-
... More
b) Cover for above cable tray
40
-
-
... More
Supply and charging of additional refrigerant R-410A in VRF System
50
-
-
... More
Power PCB of VRF high wall units
4
-
-
... More
BLDC motor of VRF high wall units
4
-
-
... More
Dismantling of existing VRF Out door unit at Terrace of Library and Conference Room
1
-
-
... More
Lifting, shifting of new VRF out door units to terrace level with the help of chain pulley, rope, crane etc
4
-
-
... More
Pressure testing of existing in door units, after connecting new outdoor units, vaccumising the same before commissioning
1
-
-
... More
Electrical connection of new VRF out door units with new thimble, glands and by using existing cables etc
4
-
-
... More
Comprehensive Annual Maintenance Contract during Warranty/Defect Liability Period of above installed VRF/VRV Air Conditioning Units: Completely free of cost (1 year from the ate of commisioning and satisfactory testing)
1
-
-
... More
Comprehensive Annual Maintenance Contract after expiry of Warranty/Defect Liability Period of above installed VRF/VRV Air Conditioning Units - 2nd Year after completing 1 year of Warranty/Defect Liability Period
1
-
-
... More
Comprehensive Annual Maintenance Contract after expiry of Warranty/Defect Liability Period of above installed VRF/VRV Air Conditioning Units - 3rd Year after completing 1 year of Warranty/Defect Liability Period
1
-
-
... More
Comprehensive Annual Maintenance Contract after expiry of Warranty/Defect Liability Period of above installed VRF/VRV Air Conditioning Units - 4th Year after completing 1 year of Warranty/Defect Liability Period
1
-
-
... More
Comprehensive Annual Maintenance Contract after expiry of Warranty/Defect Liability Period of above installed VRF/VRV Air Conditioning Units - 5th Year after completing 1 year of Warranty/Defect Liability Period
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%