Delhi University Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Delhi University - DU Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date3 Feb 2025
Closing Date17 Feb 2025
Tender Amount₹ 8,15,111
Costs
EMD
₹ 16,302Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_DU_847294_1Tender No
CEET-6337Tender Authority
Delhi University ViewPurchaser Address
-Website
http://http://www.du.ac.in/du/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Miscellaneous electrical work to be carried out in International Student House for Men at University of Delhi.
BOQ Items
... More
12 Modules
8
454
3632
... More
12 Modules
8
547
4376
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
-
-
-
... More
5 amps switch
120
103
12360
... More
5 amps socket
20
122
2440
... More
15 amps switch
60
156
9360
... More
15 amps socket
60
197
11820
... More
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
20
369
7380
... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
20
586
11720
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required.
-
-
-
... More
1 x 1.5 sq.mm
350
45
15750
... More
2 x 2.5sq.mm
150
98
14700
... More
2 x 4 sq.mm
200
147
29400
... More
Supplying and fixing of following sizes of heavy duty class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
80
90
7200
... More
Supplying and fixing suitable size G.I. box with modular plate and cover in front or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB "C" curve including connections, painting etc. as required.
10
727
7270
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 10 sq.mm + 1 X 6 Sq.mm earth wire
60
570
34200
... More
Supplying and fixing following way single pole and neutral sheet steel of MCB distribution board of 240 volts on surface/ recess complete tinned copper bus bar, neutral link, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) 12 way double door
4
2315
9260
... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
-
-
-
... More
Single pole
80
256
20480
... More
Single pole and neutral
5
599
2995
... More
Supplying and fixing following rating, four pole 415V isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 100 amps
8
1227
9816
... More
S/F/testing and commissioning of prewired LED single box type fitting (1x20 watts) complete with all accessories on the existing surface/ down rod i/c connection with 1.5 sq.mm FRLS PVC copper cond. Cable in suitable size PVC sleeve etc. as required. (TMC 501 P 1XT- LED 20W P3241) (Philips make) and having 1 Nos. of 18 watts MAS LED tubelight
40
1443
57720
... More
S/F/testing and commissioning of prewired LED double box type fitting (2x20 watts) complete with all accessories on the existing surface/ down rod i/c connection with 1.5 sq.mm FRLS PVC copper cond. Cable in suitable size PVC sleeve etc. as required. (TMC 501 P 2XT- LED 20W P3241) (Philips make) and having 2 Nos. of 18 watts MAS LED tubelight
20
2439
48780
... More
S/F of 18 watts MAS LED tubelight in the existing fitting i/c making connection etc. as required.
80
845
67600
... More
Servicing/painting the rusted panel with twoor more coat i/c rubbing the corrossion and painting the same with spray machine i/c dressing wires/ replacement of burnt thimbles etc. i/c welding
4
4000
16000
... More
Making provision for servicing/ dressing the MCBDB i/c balancing the load, replacing burnt thimbles and painting the DB inside and outside completely with two or more coat, after removing corrossion
10
500
5000
... More
Repairing the ceiling fan by replacing the defective copper winding, bearing bushes etc. as required etc. as required i/c removing and installation the same.
20
850
17000
... More
S/F of following size exhaust fan complete with all accessories i/c having suitable louver shutter etc. as required.
-
-
-
... More
15" exhaust fan
6
6926
41556
... More
S/F of snap-on DLP trunking of 80 mm x 50 mm with suitable cover on the existing wall/ surface i/c having all the accessories such as flat angle, end caps, internal/ external angle etc. as required at site.
80
1759
140720
... More
S/F of louver shutter suitable for 12/15" exhaust fan i/c fixing as required at site.
10
600
6000
... More
Supply/ installation / testing and commissioning of 200 watts flood light LED fitting having suitable angle frame, complet with all accessories i/c having pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having front opening seperate driver compartment with IP66 protection and Impact resistance of IK07 with 10KV Build In SPD i/c making connection as required. (Philips/Trilux or equivalent)
4
26769
107076
... More
Supplying / laying of one number of PVC insulated and PVC sheathed/XLPE aluminium cond. Power cable of 1.1 KV grade of following size direct in grond i/c excavation, sand cushioning , protective covering and refilling the trench etc. as required at site. 4cx16 sq.mm
60
753
45180
... More
Dismantling the existing accessories and depositing the same at Engineering Store.
1
500
500
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%