Delhi University Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Delhi University - DU Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date9 Feb 2023
Closing Date22 Feb 2023
Tender Amount₹ 8,99,078
Costs
EMD
₹ 17,982Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_DU_739666_1Tender No
CEET-4714Tender Authority
Delhi University ViewPurchaser Address
-Website
http://http://www.du.ac.in/du/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Electrical renovation work to be carried out in lab no. B-1 and B-2 other allied work to be carried out at Department of Environmental Studies, University of Delhi
BOQ Items
... More
12 Module
18
-
547
... More
6 Module
20
-
402
... More
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required. Group C
25
-
894
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required.
-
-
-
... More
1 x 1.5 sq.mm
1375
-
45
... More
2 x 2.5 sq.mm
200
-
98
... More
2 x 4 sq.mm
800
-
147
... More
2 x 6 sq.mm
375
-
216
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 4 X 16 sq. mm + 2 X 16 sq. mm earth wire
40
-
1365
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
-
-
-
... More
15/16 amps switch
72
-
156
... More
6 pin 15/16 amps socket outlet
72
-
197
... More
5/6 amps switch
50
-
103
... More
3 pin 5/6 amps socket outlet
10
-
122
... More
Supplying and fixing of following sizes of Heavy duty PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
-
-
-
... More
25 mm
150
-
45
... More
20 mm
150
-
128
... More
Supplying and fixing of suitable size G.I. box with modular plate and cover in front or surface in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB "C" curve including painting etc.
5
-
727
... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C
10
-
1467
... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required.
500
-
57
... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
-
-
-
... More
12 way (4 + 36), Double door
2
-
12833
... More
8 way (4 + 24), Double door
1
-
10165
... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
96
-
256
... More
Supplying and fixing 63 amps, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
3
-
1227
... More
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 120 sq. mm
4
-
4538
... More
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
-
-
-
... More
100A 16 KA TPMCCB
1
-
3777
... More
250A, 50KA FPMCCB
1
-
18411
... More
S/F of single box type fitting complete with all accessories i/c making connection etc. as required TMC 501 1XT- LED 22W P3242 i/c having 1 Nos. of stellar 20 watts LED tubelight in the existing fitting as required.
10
-
1063
... More
S/F of double box type fitting complete with all accessories i/c making connection etc. as required (TMC 501 P 2XT- LED 22W P3241) i/c having 2 Nos. stellar 20watts LED tube light in the existing fitting etc. as required. (Philips make)
35
-
1629
... More
S/F 1 No. RJ-45 1 Module box i/c modular plate & covering in front on surface connection etc. as required.
15
-
757
... More
S/I/T/C of Heavy Duty exhaust fan with suitable size louver shutter and making connection i/c wooden work if required. 12 Exhaust
10
-
5200
... More
Supplying and fixing of 48" ceiling fan including 3" fan rod and making connectioni etc. as required at site. (Crompton)
7
-
2430
... More
S/F DLP UPVC trunking compartment with cofe4 with cover clip on separates partition left right top internal angle, flat angle, raise function , flat function cover to body joint mosaic clip & support from mosaic 80 mm X 50 mm with all accessories
30
-
1794
... More
Finding and detecting location of underground LT cable with FLC machine including excavation, pin pointing , fault refilling after repair of ground at marked fault as required at site.
3
-
10000
... More
Making provision of digging out the fault location upto 10 mtr for making straight through joint by tracing out the loop and then refilling the trench after restoration the electric supply etc. as required.
3
-
2500
... More
Supplying, fixing and laying of one number of PVC insulated and PVC sheathed/ XLPE aluminum armoured conductor power cable confirming to 1.1 KV grade of following size direct in ground including excavation, sand cushioning , protective covering , refilling the same etc. as required. 3½ X 120 sq. mm
30
-
1885
... More
Supplying and fixing of following rating, TPN MCB 415V in the existing MCB DB complete with connecction, testing and commissioning etc. as required.
3
-
2568
... More
Servicing/ cleaning/ meggering / checking of load balancing / checknig with top tester of existing panel i/c removing the dust and carbonized and dress upt the hanging wire along with thimblf if necessary etc. as required at site.
2
-
3500