Delhi University Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Delhi University - DU Tender
Electronics Equipment
Electrical and Electronics
Eprocure
Opening Date26 Oct 2024
Closing Soon7 Nov 2024
Tender Amount₹ 9,83,268
Costs
EMD
₹ 19,665Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DU_832653_1Tender No
CEET-6026Tender Authority
Delhi University ViewPurchaser Address
-Website
http://http://www.du.ac.in/du/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
12 Module
5
547
2735
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required.
-
-
-
1 x 1.5 sq.mm
850
45
38250
2 x 2.5 sq.mm
150
98
14700
2 x 4 sq.mm
500
147
73500
2 x 6 sq.mm
200
206
41200
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
35
1005
35175
Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc. as required.
-
-
-
5/6 amps switch
15
103
1545
3 pin 5/6 amps socket outlet
35
122
4270
15/16 amps switch
100
156
15600
6 pin 15/16 amps socket outlet
100
197
19700
Supplying and fixing of following sizes of medium class PVC conduit/ batten along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
-
-
-
25 mm
100
145
14500
20 mm
80
128
10240
Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB "C" curve including connections, painting etc. as required.
10
727
7270
Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface/ recess steel/ PVC conduit as required. 1run of cable.
800
57
45600
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4+24) double door
1
10165
10165
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
24
256
6144
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
4
1034
4136
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C
10
1467
14670
Supply, installation, testing and commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Moter, Class of Insulation: B, 3 Nos. Blades, 30 cm long down rod, 2 nos. conopies, shackle kit, safety rope, copper winding, power Factor not less than 0.9, service Value (CMM/W) minimum 6.85, Air Delivery minimum 215 CMM, 350 RPM (Tolerance as per IS:374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temprature rise= 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230V, 50 Hz, single phase AC supply, earthing etc. complete as required.
6
2730
16380
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required. Group B
20
894
17880
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
15
369
5535
S/F/testing and commissioning of LED fitting single box type fitting (1x20 watts) complete with all accessories and tubes etc. on directly on ceiling or wall i/c connection with 1.5sqmm FR PVC copper cond. Cable etc. as required. (Model No. TMC 501 1 X T LED 22W P3241) (Philips)
20
1147
22940
S/F/testing and commissioning of LED fitting double box type fitting (2x20 watts) complete with all accessories and tubes etc. on directly on ceiling or wall i/c connection with 1.5sqmm FR PVC copper cond. Cable etc. as required. (Model No. TMC 501 2 X T LED 22W P3242) (Philips)
20
1645
32900
S/F DLP UPVC trunking compartment with cover clip on separates partition left right top internal angle, flat angle, raise function, flat function cover to body joints mosaic clip & support from mosaic isolation bracket 2 mm thick plastic (Legrand)
-
-
-
105 mm x 50 mm with all accessories
45
2136
96120
80 mm x 50 mm with all accessories
20
1804
36080
P/f installation, testing and commissioning of following capacity 3 pole 415 volt AC supply complete with connection in the suitable
-
-
-
100 amps MCCB 36 KA
1
9404
9404
250 amps MCCb 36 KA
1
18500
18500
S/F 1 Nos. RJ-45, 1 Module box i/c modular plate copvering in front on surface connection etc. as required.
40
759
30360
S/F testing & commissioning of of starter panel board 3 phase 4 wire system 415v, AC supply
2
14000
28000
Incoming 1 Nos. VM 0-500V
1 Nos. AM meter Analog 0-20V with in built selector switch 0-20 amps
Outgoing
1 Nos. DOL starter 1 Nos. single phase preventer 1 No. OLR indication light and ON/OFF button
Compete with all accessories.
-
-
-
Servicing/ cleaning / meggering/ checking of load balanciing / checking with ton tester of existing panel i/c removing the dust and carbonized and dress up the hanging wire along with thimble if necessary etc. as required at site.
1
5000
5000
Supplying, installation, testing and commissioning of suitable size cubical panel wall mounted 3 phase 4 wire system compartmentized in multititer , vermin and dust proofed the cubical panel made of 16 gauge CRCA sheet supported on angle channel. The door shallbe made out of 16 gauge CRCA sheet duly painted and having the suitable size following
1
282399
282399
250 amps MCCB 35 KA- 1 No.
100 amps MCCB 35 KA – 3 Nos.
TPN MCB 63 amps -3 Nos.
DP MCB 63 amps -3 No.
Amp meter in the suitable CT (0-500 a) -1 Nos.
Volt meter in the selector switch (0-500 V) – 1 Nos.
CT 200/5 -3 Nos.
Induction light (RYB) – 3 Nos.
The main aluminium 400 amps bus bar 3 phase 4 wire system mounted on with heat shrinkable sleeve
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%