If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Delhi University - DU Tender
Electrical and Electronics
Eprocure
Opening Date14 May 2024
Closing Date3 Jun 2024
Tender Amount₹ 2,74,437
Costs
EMD
₹ 5,489Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DU_807160_1Bid Award Id
ViewTender No
CEET-5614Tender Authority
Delhi University ViewPurchaser Address
-Website
http://http://www.du.ac.in/du/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Repairing/ rewinding of existing 20 HP booster pump in Multistory Building, 10 HP booster pump in Kanad Bhawan, 10 HP open well submersible pump in Central Office and 7.5 HP open well submersible pump in ARC Building , University of Delhi
BOQ Items
Supplying and fixing of gun metal gate valve of following size etc. as required at site. 50 mm
2
1756
878.25
Providing and fixing G.I. union for G.I. pipe including cutting and threading the pipe and making long screw etc. complete
4
2826
706.7
S/D the following size FRLS of PVC insulated copper conductor cable in the existing surface/ recess PVC conduit as required. 6x6 sqmm
5
2990
598
S/F testing and commissioning of panel board 3 phase 4 wire system 415v, AC supply
1
14000
14000
Incoming 2 Nos. VM 0-500V
1 nos. AM meter analog 0-20V with in built selector switch 0-20 amps Outgoing
1 Nos. DOL starter 1 Nos. Single phase preventer 1 Nos. OLR Indication light and ON/OFF button
Complete with all accessories (Reids Line and ISH Hostel)
-
-
-
Fully rewinding of following booster pump after cutting the existing winding with super enameled copper wire at the existing gauge i/c varnishing, heating etc. as required a site.
-
-
-
10 HP booster pump (Kanad Bhawan)
1
15000
15000
20HP booster pump (Multistory)
1
30000
30000
Fully rewinding of following open well pump after cutting the existing winding with super enameled copper wire at the existing gauge i/c varnishing, heating etc. as required a site.
-
-
-
10 HP open well (Central Office
1
15000
15000
7.5 HP open well (ARC Building
1
11500
11500
Supplying and fixing of imellor gun metal for repairing of 20 HP booster pump etc. as required at site. (Beacon make)
1
8000
8000
Supplying and fixing of fun metal bush for the existing open well submersible pump etc. as required at site. (Central office/ ARC)
4
12000
3000
Providing and fixing of ball bearing suitable for 5 HP and 20 HP booster pump etc. as required at site. (Multistorey and Kanad Bhawan)
-
-
-
(a) 6308
2
1700
850
(b) 6306
2
1500
750
© 6312
1
1000
1000
Supplying and fixing of OLR 20-30 amps for the existing pump etc. as required at site.
1
1615
1615
Supplying and fixing of contactor suitable for 10 HP submersible pump 3 pole 440 volt 50 Hz making connection etc. as required at site. (C & S) ( Model no. TC1C X 254 Code 8536) (Central Office/ ARC)
1
2877
2877
Supplying and fixing of water sensor for the existing pump and making connection etc. as required at site. (Central Office/ ARC)
2
7000
3500
Supplying and fixing of mechanical seal for the 7.5/10 HP open well submersible pump etc. as required at site.
4
18000
4500
S/F of following PVC insulated and PVC sheathed copper conductor flexible cable i/c connection etc. as required
-
-
-
3x4 sqmm
30
8040
268
3x1.5 sqmm
30
5700
190
Providing and fixing of 50 mm foot ball for the existing 7.5/10 HP open well pump etc. as required at site. (make DRP)
4
12000
3000
S/I/T/C of Automatic star delta ML2 starter of 3 phase, 415Volt, AC supply suitable for 20 HP L & L ML 2 fully automatic i/c making connection etc. as required at site. (Multistory)
1
35500
35500
Providing and fixing of 3 HP motor of the hiring charging for the removing of water from the tank by the suitable arrangement etc. as required. (Central Office /ARC)
2
5000
2500
Providng and fixnig of G.I. union , socket, nipple, bend for G.I. pipe including cutting and threading the pipe and making long screws etc.
4
10000
2500
Supplying and fixing following 63 amps TPN MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2
5136
2568
Removing & refixing of existing booster/ open well submersible pump set for its position as required at site.
4
6000
1500