Delhi University Tender
... More
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Delhi University - DU Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date6 Mar 2025
Closing Date17 Mar 2025
Tender Amount₹ 1,26,34,230
Costs
EMD
₹ 2,52,685Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_DU_852213_1Bid Award Id
ViewTender No
CEET-6429Tender Authority
Delhi University ViewPurchaser Address
-Website
http://http://www.du.ac.in/du/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Retrofitting and repairing of existing VRV/VRF air-conditioning system at Second Floor and Basement in Permanent Stand at Sports Complex. Cluster Innovation Centre, University of Delhi. (Part-B)
BOQ Items
... More
2.0 TR 4 way Cassette Type IDU having 812 CFM (f3/min)
5
72330
361650
... More
3.0 TR 4 way Cassette Type IDU having 1200 CFM (f3/min)
5
106773
533865
... More
4.0 TR 4 way Cassette Type IDU having 1624 CFM (f3/min)
5
111939
559695
... More
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation /with Class- O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :(NOTE :- 1) The Copper Piping & Piping Circuit should be with Minimum Number of joints, which shall be attained by : (i) Using One End Expanded Tubes (ii) Bending the tubes instead of using elbow joints wherever 90 degree bending is required. (2) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimum. (3) The makes of tube fittings shall be same as that of tubes. (4) The thickness of fittings used shall be same as that of the pipe.)
-
-
-
... More
41.27mmdia(OD)(Harddrawn)with tube thickness1.62mm with19 mm thick insulation
20
3000
60000
... More
34.9 mm dia (OD) (Harddrawn) with tube thickness 1.62 mm with 19 mm thick insulation
15
2500
37500
... More
28.58 mm dia (OD) (Harddrawn) with tube thickness 1.2 mm with 19 mm thick insulation
30
2000
60000
... More
22.2 mm dia (OD) (Harddrawn) with tube thickness 1.2 mm with 19 mm thick insulation
30
1800
54000
... More
15.86 mm dia (OD) (Softdrawn)with tube thickness 1.2 mm with 19 mm thick insulation
60
1711
102660
... More
12.7mmdia(OD)(Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation
50
1600
80000
... More
9.5mm dia (OD) (Softdrawn) with tube thickness 1.2mm with 19mm thick insulation
80
1504
120320
... More
6.4 mm dia (OD) (Softdrawn) with tube thickness 1.2mm with 19mm thick insulation
30
1200
36000
... More
Supply , Installation , testing and commissioning of unarmoured 2 core X 1.5 sqmm copper wire between indoor units and their wired remote as per requirement and specifications.
150
150
22500
... More
Supply , Installation , testing and commissioning of drain pipe of 25mm dia UPVC pipe complete with fittings, supports duly insulated on surface/recess i/c cutting and making good the same etc. as required (Astral/ Finolex)
500
180
90000
... More
Topping up of VRF/ VRV airconditioning system with Refrigerant R 410 A as per the requirement at site.
135
1700
229500
... More
Provision of UV coating treatment of approved make on Outdoor Units.
13
22500
292500
... More
Supply , Installation , testing and commissioning of 'Y' joints for Outdoor VRV/ VRF units.
6
11590
69540
... More
Supply , Installation , testing and commissioning of 'Y' joints for Indoor VRV/ VRF units.
9
8500
76500
... More
Dismantling the existing defective VRV/ VRF units from roof of the building and depositing the same at Engineering store
1
120000
120000