If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Delhi University - DU Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date14 Oct 2024
Closing DateCancelled
Tender Amount₹ 4,37,834
Costs
EMD
₹ 8,757Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DU_830603_1Bid Award Id
ViewTender No
CEET-5975Tender Authority
Delhi University ViewPurchaser Address
-Website
http://http://www.du.ac.in/du/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Electrical work to be carried out in resident vacant flat in 23/1 at Cavalry Lane, University of Delhi.
BOQ Items
... More
6 Modules
20
402
8040
... More
8 Modules
1
454
454
... More
12 Modules
5
547
2735
... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group B
30
1182
35460
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required.
-
-
-
... More
1 X 1.5 sq.mm
450
45
20250
... More
2 X 2.5 sq.mm
125
98
12250
... More
2 X 4 sq.mm
200
147
29400
... More
2 X 6 sq.mm
125
216
27000
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 x 10 + 1 x 6 sq.mm
30
570
17100
... More
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. Group B
25
637
15925
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
-
-
-
... More
5/6 amps switch
40
103
4120
... More
3 pin 5/6 amps socket outlet
15
122
1830
... More
15/16 amps switch
36
156
5616
... More
6 pin 15/16 amps socket outlet
36
197
7092
... More
Bell Push
2
140
280
... More
Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB "C" curve including connections, painting etc. as required.
7
727
5089
... More
Supplying and fixing of modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
7
40
280
... More
S/F of suitable size G.I. box with modular plate and cover in front or surface in recess including providing and fixing 6 pin 5/6 & 15/16A modular socket outlet and 15/16A modular switch, connection etc.
4
586
2344
... More
S/F of brass batten/holder including connections etc as reqd
6
131
786
... More
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
7
369
2583
... More
Supply, installation, testing and commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Moter, Class of Insulation: B, 3 Nos. Blades, 30 cm long down rod, 2 nos. conopies, shackle kit, safety rope, copper winding, power Factor not less than 0.9, service Value (CMM/W) minimum 6.85, Air Delivery minimum 215 CMM, 350 RPM (Tolerance as per IS:374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temprature rise= 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230V, 50 Hz, single phase AC supply, earthing etc. complete as required.
6
2730
16380
... More
Supplying and fixing of following sizes of Heavy duty class PVC conduit /Batten along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
-
-
-
... More
25 mm
100
145
14500
... More
20 mm
75
128
9600
... More
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
10
87
870
... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
1
99
99
... More
Supplying and fixing following way single pole and neutral sheet steel of MCB distribution board of 240 volts on surface/ recess complete tinned copper bus bar, neutral link, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) 12 way double door
2
2315
4630
... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
20
256
5120
... More
Supplying and fixing 40/63 amps, double pole, 240 volts, DP MCB in the existingt MCB DB complete with connections, testing and commissioning etc. as required.
2
527
1054
... More
S/F of single box type fitting complete with all accessories i/c making connection etc. as required. TMC 501 1XT- LED 22w P3242 i/c having 1 No. of stellar 20 watts LED tube light in the existing fitting as required.
7
1147
8029
... More
S/F fancy lights / wall bracket with forsted glass, B22 holder, brass frame including making connection etc. as required at site. (Philips)
15
761
11415
... More
S/F LED 72 watts street lights fitting luminaire with pressure dia cast aluminium and heat resistance toughened flat glass complete with accessories top opening compartment with IP66 protection with 7200 lumens 220-240V i/c making connections etc. as required (model No. BRP409 LED CW 074 CW HE MR S1 PSU GR) (Philips)
2
10603
21206
... More
Supplying and fixing of LED 12 watts ceiling circular including making connection etc. as required at site. (Philips)
4
1231
4924
... More
Supplying and fixing of street light pole box of size 8"x10" complete with all accessories i/c suitable clamps, suitable bakelite sheet, brass screws, washers and 1 Nos. SP MCB 10 amps capacity i/c making connection etc. as required at site.
2
1604
3208
... More
Supplying, fixing and laying of one number PVC insulated and PVC sheathed/ XLPE aluminium armoured conductor power cable confirming to 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering, refilling the same etc. as required.
-
-
-
... More
4x16 sq.mm
100
704
70400
... More
3x6 sq.mm
100
619
61900
... More
Supplying and fixing following rating 63 amps double pole RCCB (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1
4019
4019
Evaluation Notes How It Works ?