Delhi University Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Delhi University - DU Tender

Works
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date22 Jun 2024
Closing DateCancelled
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
S/I/T/C of Air-Cooled VFD Screw Chillers of Actual capacity of min 3 x 145 TR for Biotech centre building University of Delhi South Campus.
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
1 set - Microprocessor based HMI control panel complete with accessories as per specifications.

-

-

-

... More
Chilling machine described above, as per specifications and complete in all respects for the operating parameters as given under.

-

-

-

... More
Cooling Capacity (Actual) : 145 TR

-

-

-

... More
Type of Refrigerant : R-134a

-

-

-

... More
Chilled Water In Temperature : 12.22 Deg C

-

-

-

... More
Chilled Water Out Temperature: 6.67 Deg C

-

-

-

... More
Fouling Factor:0.0005 FPS

-

-

-

... More
Design Air Entering Temperature: 50 Deg C

-

-

-

... More
IKW/TR on design conditions shall not exceed (100% load) 1.35 for complete unit.

-

-

-

... More
a) Factory Test point at site/design Condition are following.

-

-

-

... More
1) 100 % Load

-

-

-

... More
2) 75% Load

-

-

-

... More
3) 50% Load

-

-

-

... More
4) 25% Load

-

-

-

... More
Chilling machines as described above (2W+1S)

3

20075589

6691863

... More
Primary Chilled Water Pumps Supply, installation, testing and commissioning of End suction back pull out type chilled water circulating pump sets complete with coupling,T.E.F.C. motor, base plate, mechanical seal, Priming Funnel , air vent cock etc. as per specifications and drawings. Chilled water 821 LPM, (216 GPM) at head 15 mtr.

3

318600

106200

... More
Secondary Chilled Water Pumps Supply, installation, testing and commissioning of variable speed pumping system consisting of the following: End section circulating Pump sets complete with coupling, T.E.F.C. motor, base plate, Priming Funnel, air vent, air cock etc. as per specifications and drawings having capacity 1232 LPM (324 GPM) at 20 m head.

4

826000

206500

... More
Adjustable variable frequency drive suitable for pump and to be suitable for inter facing with other system components & Auto/ Manual changeover arrangement. Differential pressure sensor. Microprocessor based logic controller common for above pumps complete with necessary software duly downloaded.

1

590000

590000

... More
Air Handling units (Ceiling suspended type) Testing and commissioning of factory built floor mounted chilled water double skin type horizontal/vertical air handling units made of 25mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/PVC eliminators, cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5mm) cooling coil of 6 row deep, filter section with 50mm thick metal viscous/ washable synthetic type air prefilters, belt drive package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply suitably designed for varialbe frequency drive applications, drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 nos.)and industrial type thermometers (2 nos.) at the inlet and outlet of coil, auto purge valve wherever required, necessary vibration isolation arrangement etc. complete as per specification and of following capacities.

-

-

-

... More
8500 CMH

2

345934

172967

... More
6800 CMH

11

1535831

139621

... More
3400 CMH

5

528055

105611

... More
2040 CMH

55

2283270

41514

... More
Treated Fresh Air Handling Units (TFA) : Providing and fixing of unitary type double skin treated fresh air handling units complete with thermal break profiles, 50mm thick insulated panels, fan, cooling coil section with coil, filter section with filters, fan motor, drive set, mounting base damper etc. as per specifications and drawings. 4000 CMH, 8 row deep coil cooling.

4

1321600

330400

... More
Providing and fixing fan coil unit complete with fan section, fan motor, Cooling Coil, Filter Selection with standard filters, fan motor, drive belt, fresh air damper 2-way motorised control valve etc. as per specification and drawings

-

-

-

... More
3 TR

4

128000

32000

... More
2.5 TR

5

135000

27000

... More
2.0 TR

27

648000

24000

... More
1.5 TR

26

572000

22000

... More
1 TR

1

19000

19000

... More
INSULATED CHILLED WATER PIPING (Nitrite rubber insulation) Supplying,laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but as excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 kg/cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repariring of damage to building etc. as per specifications and as required complete in all respect. Note:- the pipes of sizes 150mm & below shall be M.S. 'C' class as per IS: 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.

-

-

-

... More
200 mm dia(32 mm thick insulation)

48

299616

6242

... More
150 mm dia(32 mm thick insulation)

36

154008

4278

... More
125 mmdia(32 mm thick insulation)

120

449040

3742

... More
100 mm dia(32 mm thick insulation)

48

143040

2980

... More
80 mm dia(32 mm thick insulation)

36

80136

2226

... More
65 mm dia(32 mm thick insulation)

36

64584

1794

... More
50 mm dia(32 mm thick insulation)

48

74544

1553

... More
40 mm dia(32 mm thick insulation)

120

150840

1257

... More
32 mm dia(19 mm thick insulation)

240

251280

1047

... More
25 mmdia(19 mm thick insulation)

144

125136

869

... More
INSULATED VALVE:- Supplying,fixing, testing and commissioning of following valves, strainers, gauges in the Chilled water plumbing duly insulated to the same specifications as the conncected piping and adequately supported as per specifications. Butterfly Valve (Manual) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water circulation as specified.

-

-

-

... More
125 mm

22

183326

8333

... More
50 mm

13

53677

4129

... More
32 mm

5

14325

2865

... More
25 mm

55

192555

3501

... More
Supplying,fixing, testing and commissioning of following valves, strainers, gauges in the Chilled water plumbing duly insulated to the same specifications as the conncected piping and adequately supported as per specifications. Balancing Valve with Built in Measuring Facility with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled/hot water circulation as specified. 125 mm

3

79428

26476

... More
Supplying,fixing, testing and commissioning of following valves, strainers, gauges in the Chilled water plumbing duly insulated to the same specifications as the conncected piping and adequately supported as per specifications. Non Return Valve with dual plate of CI body and SS plates vulcanized NBR seal flanged and PN 16 pressure rating as specified. 125 mm

7

55069

7867

... More
Supplying,fixing, testing and commissioning of following valves, strainers, gauges in the Chilled water plumbing duly insulated to the same specifications as the conncected piping and adequately supported as per specifications. Y - Strainer of Ductile CI Body flanged ends with stainlesssteel strainer for condensor water circulation as specified. 125 mm

7

153468

21924

... More
Supply and fixing of the industrial type pressure gauges with gun metal / brass valves complete as required.

80

95680

1196

... More
Supply and fixing of in position the mercury in glass industrial type Thermometers.

80

83440

1043

... More
Flow Switches

3

16284

5428

... More
Auto Air vent 25 mm dia

3

8496

2832

... More
Providing & fixing of motorized 2-way modulating valves for AHUs. Flow Rate 25-39 USGPM

77

2448908

31804

... More
Providing & fixing of motorized 2-way Modulating valves for FCUs.

63

1014741

16107

... More
Expansion tank Providing and fixing HDPE open Expansion Tank with 50 MM thick insulation and cladded with 26 G aluminium cladding as per specifications and drawings. Size : 1000 liter Capacity

1

69525

69525

... More
Pipe Cladding Aluminum cladding with 0.5 mm aluminum sheet with 50mm overlap on joints and fixed with self-allaying screws etc. as per specificationsand drawing. Aluminum cladding on pipes.

200

188800

944

... More
Drain Piping:Providing and fixing pipes with all necessary fittings, supports and insulations.PVC pipe with 06 mm nitrile insulation complete with fittings, supports, valves and Insulation as per specifications and drawings.

-

-

-

... More
40 mm

100

47200

472

... More
32 mm

100

35400

354

... More
25 mm

250

82500

330

... More
Ducting: Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.63 mm sheet

430

454940

1058

... More
Duct Acoustic Lining : Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications 25 MM thick

430

304440

708

... More
Duct Insulation : Supply, installation, testing and commissioning of glass wool insulationwith factory faced aluminium foil, chicken wire netting aluminium adhesive tape etc. on ducts complete as per specifications and drawings. 25 MM thick

200

283200

1416

... More
Providing and fixing extruded vertical Aluminum grilles duly powder coated as per specifications and drawings.

-

-

-

... More
Aluminum linear supply air grilles with damper

10

91050

9105

... More
Aluminum linear supply air grilles without damper

10

59100

5910

... More
Volume Control Dampers

10

121840

12184

... More
Fire Damper: Providing and fixing duct/wall mounted galvanised sheet fire damper with limit switch as per specifications and drawings

10

106590

10659

... More
Motorised spring return actuator for Dampers with control panels.

4

39792

9948

... More
Thermostat : Proportionating thermostat (Cooling/ Heating)

18

354708

19706

... More
Pressurization Blowers : Providing and fixing of SISW blower, complete with drive, base, motoretc. as per specifications and drawings. 5,100 Cubm/Hr.

4

173224

43306

... More
Fresh Air Louvers: Providing and Fixing of extruded aluminium louvers with frame manual damper birdscreen, etc. as per specifications and drawings. Fresh air louver & bird mesh screen as per specifications

10

103840

10384

... More
Acoustic treatment : Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610mm x 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications.

150

184350

1229

... More
Electrical Control Panel: Supply, installation, testing and commissioning of main panel boards made of 2.0 mm thick steel sheet duly power coated complete with voltmeter, ammeter, indicating lights, selection switch, incoming/ outgoing isolators, current operated single phase preventor, power contactors, A/M Switch for remote controls operation complete as per specifications and drawings and as required.

-

-

-

... More
Main A.C. Panel-p1 Incomer 1 No.1600 Amps ACB, TP+NL 1 No. voltmeter with selector switch 1 No.CT operated ammeter with selector switch 3 Nos. phase indicating lamps Bus bar 1 No. 1600 Amps aluminium bus bar duly sleeved Outcomer 3 No. 400 Amps MCCB TP+NL for air cooled chillers 4 No. 16 Amps MCB TP+NL for primary chilled water pumps 4 No. 40 Amps MCB TP+NL for secondary chilled water pump Nos. VFD starter 5 No. Digital type ammeters 10 No. ON/OFF push buttons 10 No. ON/OFF indicating lights

1

1050000

1050000

... More
Panel p2 (TFA) 1 No.32 Amps ACB, TP+NL outgoing 1 No. automatic DOL starter 1 No. Single phase preventer 1 No. Digital type ammeter 2 No. ON/OFF push buttons 2 No. ON/OFF indicating lights

4

85600

21400

... More
Panel P3 (AHUs 0.75 KW motor) 1 No.32 Amps MCB TP+NL incoming 2 No. 16 Amps MCB TP+NL outgoing 2 No. automatic DOL starter 2 No. single phase preventer 1 No. Digital type ammeter 4 No. ON/OFF push buttons 4 No. ON/OFF indicating lights

18

444600

24700

... More
Providing and fixing pvc insulated armoured aluminium conductor cables from main panel boards to various equipments through wall/ celling with appropriate clamps and fixing arrangements etc. as per specifications and drawings.

-

-

-

... More
3.5 Core -185 sqmm (Aluminium Armoured Cable )

100

376900

3769

... More
3 Core -4 sqmm (Cu Arm Cable )

300

260400

868

... More
4 Core -1.5 sqmm (Cu Arm Cable )

150

78000

520

... More
Control cabling: 4 Core -2.5 sqmm (Cu Arm Cable )

150

116250

775

... More
Double earthing continuity conductors between panel boards and Equipments as required and as per I.E. rules 1956. 8 SWG G.I Wire.

1

18880

18880

... More
G.I. Strip of size 25X6 MM as required from Panel to chiller and Boiler.

100

24400

244

... More
PART D - Comprehensive Annual Maintenance Contract - 5 years

-

-

-

... More
1st Year after expire of warranty

1

813191

813191

... More
2nd year after expire of warranty

1

813192

813192

... More
3rd Year after expire of warranty

1

1219787

1219787

... More
4th Year after expire of warranty

1

1626382

1626382

... More
5th Year after expire of warranty

1

1626383

1626383

... More
Part E- Buy Back

-

-

-

... More
Buyback for dismantled Material (To kept by the Contractor) including dismentling and Shifting of following material. All material consider to be as assorted. 145 TR x 3 Air cooled Chiller Plant including Pumps, piping , Electrical Panel, AHU, FCU extra.

1

-2181018

2181018



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.