Delhi Transport Corporation Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Delhi Transport Corporation - DTC Tender

Works
Electrical and Electronics
Eprocure
Opening Date29 Jul 2024
Closing Date13 Aug 2024
Tender Amount₹ 36,44,563 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required

900

252900

281

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.

-

-

-

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

1200

164400

137

... More
2 X 6 sq. mm + 1 X 6 sq. mm earth wire

750

170250

227

... More
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire

900

193500

215

... More
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.

-

-

-

... More
Group C

30

13560

452

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.

-

-

-

... More
3 x 2.5 sq. mm

200

15000

75

... More
3 x 4 sq. mm

300

33300

111

... More
5 x 4 sq. mm

300

54600

182

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
25 mm

700

48300

69

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

-

-

-

... More
5/6 A switch

25

2100

84

... More
15/16 A switch

50

5700

114

... More
3 pin 5/6 A socket outlet

25

2025

81

... More
6 pin 15/16 A socket outlet

50

7650

153

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.

-

-

-

... More
3 Module (100 mmX75 mm)

10

1850

185

... More
6 Module (200 mmX75 mm)

5

1290

258

... More
8 Module (125 mmX125 mm)

5

1485

297

... More
12 Module (200 mmX150 mm)

15

5160

344

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.

100

40600

406

... More
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.

450

20700

46

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

70

20160

288

... More
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.

-

-

-

... More
Group C

30

12450

415

... More
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.

-

-

-

... More
100 A, 30kA, FPMCCB

6

32160

5360

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
12 way, Double door

1

1151

1151

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
6 way (4 + 18), Double door

8

21272

2659

... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)

-

-

-

... More
4 way (4 + 12), Double door

2

9004

4502

... More
8 way (4 + 24), Double door

1

5664

5664

... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Single pole

144

24912

173

... More
Triple pole

16

11200

700

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
63 A

1

2242

2242

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
63 A

8

18416

2302

... More
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A, 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.

4

2508

627

... More
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

10

9800

980

... More
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A, "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

5

12440

2488

... More
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.

8

29376

3672

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

150

19350

129

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required.

100

2300

23

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required.

-

-

-

... More
Upto 35 sq. mm (clamped with 1mm thick saddle)

200

5000

25

... More
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

350

25200

72

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.

-

-

-

... More
2 X 16 sq. mm (22mm)

2

340

170

... More
4 X 35 sq. mm (32mm)

2

566

283

... More
4 X 50 sq. mm (35 mm)

2

716

358

... More
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.

-

-

-

... More
4 X 35 sq. mm

3

4245

1415

... More
4 X 50 sq. mm

3

4941

1647

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.

-

-

-

... More
120 mm dia (OD-120 mm & ID-103 mm nominal)

50

8650

173

... More
Supply of XLPE insulated PVC Sheathed Armoured Aluminium Conductor cable 1.1KV Grade Conforming to IS-7098 of size 2x16 Sq. mm.

100

27900

279

... More
Supply of XLPE insulated PVC Sheathed Armoured Aluminium Conductor cable 1.1KV Grade Conforming to IS-7098 of size 4x35 Sq. mm.

150

94350

629

... More
Supply of XLPE insulated PVC Sheathed Armoured Aluminium Conductor cable 1.1KV Grade Conforming to IS-7098 of size 4x50 Sq. mm.

200

168000

840

... More
S/I/T/C of LED Fitting 20 watt 6500k

290

111650

385

... More
S/I/T/C of led panel 36 watts 2'X2' 6500K

4

8684

2171

... More
S/I/T/C of High Speed Ceiling Fan 48"

70

200900

2870

... More
S/I/T/C of LED flood light fitting 100 watt IP -66 protection

30

189180

6306

... More
S/I/T/C of LED flood light fitting 60 watt IP -66 protection

5

20935

4187

... More
S/I/T/C of LED flood light fitting 250 watt IP -66 protection

9

90117

10013

... More
S/I/T/C of 380mm Exhaust fan heavy duty 1400 RPM single phase

8

44912

5614

... More
S/I/T/C of 300mm Exhaust fan heavy duty 1400 RPM single phase

10

40540

4054

... More
S/I/T/C of 600mm Industrial Wall fan 1440 RPM single phase

15

213720

14248

... More
Supplying, fixing and Installing of 63A TPN rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Three poles and Neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required.

4

7940

1985

... More
Dismentling work of old defective electrical installtions

1

10000

10000

... More
L.T Panel, for Admin block (Please go through for complete description of S.no. 46 schedule as per tender document) Design, manufacture, supply, installation, testing and commissioning of following Utility panels suitable for 415 V, 3 phase, 4 wire, 50 Hz power distribution system. The panel shall be Indoor, free standing, floor mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalised design fabricated out of 2mm thick CRCA sheet steel for Load bearing members and 1.6 mm thick for non-load bearing members, complete with colour coded, heat shrinkable PVC insulated, aluminium bus bars and separate earth bus bar of adequate cross section through out the length of the panel. The incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber (form-3b Construction). The panel shall be complete with name plate, earthing, numbering, danger plate etc. as required and as per specifications and drawings. The panel shall withstand the fault level of as indicated elsewhere or shown in Single Line Diagram. Important Notes: Common for all Switchboard: The BOQ shall be read inconjunction with general notes, specification and Single Line Diagram (attached for Ref.). Incase of any discrepancy between specification, BOQ and SLD, the same shall be brought to the notice of Client/Consultant before quoting the rates, otherwise stringent condition shall be deemed to have been considered. Fault current wherever mentioned shall be Ics value. (Ics = 100% Icu). All MCCB shall be provided with door interlocked rotary handle with ON/TRIP/OFF position indicator, continious variable thermal magnetic O/C and S/C releases. All rating MCCB's shall be thermalmagnetic type. Incoming MCCBs shall be provided with O/C, S/C, and Earth fault protection releases. Outgoing MCCBs shall be provided with O/C, short circuit protection. All feeder doors shall have pad locking arrangement. All TP feeders shall have solid isolable neutral link. All MCCB used in starter feeder shall be suitable for motor duty application. All power contactors including NIC shall be of AC3 duty. All switchgear used in starter feeder shall be type-2 co-ordinated. Manufacturer is required to submit manufacturers type-2 co-ordination chart for the make used. All meters are digital type. Panel shall be powder coated of approved shade with minimum 60 micron thickness. ACB's/MCCB's in one particular panel shall be of one similar make. Size of Voltmeter / Ammeter for incomer also, 96mm x 96mm flush mounted with shrouded terminal shall be used in the panel. Bus bar chamber shall be kept at top of the all panels. All bus bar shall be insulated with coloured PVC Sleeve i.e.RYB,BK as per colour code. Internal wiring of panel shall be with size 2.5sqmm Flexible Copper Conductor for CT circuit and control wiring with 1.5 sqmm. All Lift Panels transport section should not be more then 1000 mm. In soft starter Vender should supply power contactor with aux. Contactor & All necessary accessories required etc. (As per BOQ & specification ) All indicating light shall be LED type . Each vertical section of floor mounted panel shall have independent base frame (75mm x 40mm) size made out of 3 mm sheet steel (LT Panel & DG Panel). All the makes shall be as per Client approved make list only. Wherever only voltmeter & ammeter are required, the same may be provided in combined meter suitable for both parameter. Incoming: One (1) Nos. 250 A FP MCCB, 36 kA thermal megnatic release One (1) No. digital multifunction meter for measurement of voltage and currents with selector push buttons (ELF-3259 of conzerv or equivalent) and one set of CTs of ratio 250 /5A, CL 0.5, 15 VA. 3 Nos. phase indication lamps and 3 Nos. status indication lamps for ON/OFF/ Trip with control SP MCB. Busbar : 300A TPN Al. Busbar of short circuit withstand capacity 36kA. Busbar shall be insulated with heat shrinkable sleeves and shall be color coded. Outgoing : All MCCB outgoing feeders shall be of 25 kA breaking capacity and shall be provided with ON/OFF / Trip indication lamps with back up SP MCB. One (1) Nos. 160A FP MCCB, One (1) Nos. 125A FP MCCB, Five (V) Nos. 100A FP MCCB MDB described as above. (CPRI Approved)

1

230256

230256

... More
Dismantling work of LT Panel, Cables and other allied work as per site requirement.

1

5000

5000

... More
Salvage value of old defective ceiling fan

60

-30000

500

... More
(+) Add prevailing cost index @ 31.27% On DSR-2016 Amount

1860683

581835

0.31

... More
(-)@9.5% below on (DSR-2016 Rate+Add prevailing cost index @ 31.27%) (1860683.00 + 581835.57)

2442518.57

-232039

0.1



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.