Delhi Transport Corporation Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Delhi Transport Corporation - DTC Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date21 Mar 2023
Closing Date28 Mar 2023
Tender Amount₹ 18,59,033 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

200

56200

281

... More
Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.

-

-

-

... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

100

11200

112

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

200

27400

137

... More
.4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire

200

43000

215

... More
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required.

-

-

-

... More
Group C

50

22600

452

... More
Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections butexcluding modular plate etc. as required.

-

-

-

... More
5/6 A switch

70

5880

84

... More
15/16 A switch

45

5130

114

... More
3 pin 5/6 A socket outlet

40

3240

81

... More
6 pin 15/16 A socket outlet

45

6885

153

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

30

8640

288

... More
Supplying and fixing metal box of following sizes (nominal size)on surface or in recess with suitable size of phenolic laminatedsheet cover in front including painting etc. as required

-

-

-

... More
180 mm X 100 mm X 60 mm deep

30

3990

133

... More
250 mm X 300 mm X 60 mm deep

15

5055

337

... More
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single corecable in surface/ recessed PVC conduit, and earthing the pointwith 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.

-

-

-

... More
Group C

50

20750

415

... More
Providing and fixing following rating and breaking capacity and pole MCCB with thermo magnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.

-

-

-

... More
100 A, 30kA, FPMCCB

6

32160

5360

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
8 way, Double door

2

2122

1061

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
12 way, Double door

3

3453

1151

... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)

-

-

-

... More
4 way (4 + 12), Double door

6

27012

4502

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
6 way (4 + 18), Double door

5

13295

2659

... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required

-

-

-

... More
Single pole

147

25431

173

... More
Single pole and neutral

4

1780

445

... More
Triple pole

17

11900

700

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required

-

-

-

... More
63 A

5

11510

2302

... More
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A, "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

35

34300

980

... More
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A, "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

12

29856

2488

... More
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.

5

18360

3672

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

50

6450

129

... More
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering

-

-

-

... More
Up to 35 sq. mm

1100

67100

61

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.

-

-

-

... More
2 X 16 sq. mm (22mm)

20

3400

170

... More
3½ X 95 sq. mm (45 mm)

8

3856

482

... More
4 X 16 sq. mm (28mm)

20

5100

255

... More
4 X 25 sq. mm (28mm)

20

5160

258

... More
4 X 35 sq. mm (28mm)

10

2830

283

... More
Supply of XPLE insulated PVC sheathed AL conductor cable 1.1 KV grade conforming to IS-7098 of size 2X16 sq. mm.

550

92400

168

... More
Supply of XPLE insulated PVC sheathed AL conductor cable 1.1 KV grade conforming to IS-7098 of size 4X16 sq. mm.

185

48285

261

... More
Supply of XPLE insulated PVC sheathed AL conductor cable 1.1 KV grade conforming to IS-7098 of size 4X35 sq. mm.

220

95480

434

... More
S/I/T/C of LED tube fitting 20 watt

100

46800

468

... More
S/I/T/C of Ceiling Fan 48" (1200mm) 380RPM

30

85350

2845

... More
S/I/T/C of LED flood Light 100 watt

10

58400

5840

... More
S/I/T/C of LED High Bay flood Light 80 watt

24

145728

6072

... More
Dismantling work of old/Existing electric fittings as required

3

8028

2676

... More
L.T Panel, for Admin block S/I/T/C of following Utility panels suitable for 415 V, 3 phase, 4 wire, 50 Hz power distribution system. The panel shall be Indoor, free standing, floor mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalized design fabricated out of 2mm thick CRCA sheet steel for Load bearing members and 1.6 mm thick for non-load bearing members, complete with colour coded, heat shrinkable PVC insulated, aluminium bus bars and separate earth bus bar of adequate cross section throughout the length of the panel. The incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber (form-3b Construction). The panel shall be complete with name plate, earthing, numbering, danger plate etc. as required and as per specifications and drawings. The panel shall withstand the fault level of as indicated elsewhere or shown in Single Line Diagram. Important Notes: Common for all Switchboard: The BOQ shall be read in conjunction with general notes, specification and Single Line Diagram (attached for Ref.). In case of any discrepancy between specification, BOQ and SLD, the same shall be brought to the notice of Client/Consultant before quoting the rates, otherwise stringent condition shall be deemed to have been considered. Fault current wherever mentioned shall be Ics value. (Ics = 100% Icu). All MCCB shall be provided with door interlocked rotary handle with ON/TRIP/OFF position indicator, continious variable thermal magnetic O/C and S/C releases. All rating MCCB's shall be thermal magnetic type. Incoming MCCBs shall be provided with O/C, S/C, and Earth fault protection releases. Outgoing MCCBs shall be provided with O/C, short circuit protection. All feeder doors shall have pad locking arrangement. All TP feeders shall have solid isolable neutral link. All MCCB used in starter feeder shall be suitable for motor duty application. All power contactors including NIC shall be of AC3 duty. ..................Details shedule of works as per tender document

2

523500

261750

... More
Add cost index @ 22.69% On DSR-2016 rate (Item no. 01 to 21)

680025

154297

0.23

... More
(-)@9.5% below on (DSR-2016 Rate +Add prevailling cost index @ 22.69%0

834322.67

-79260

0.1



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.