Delhi Transport Corporation Tender
... More
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Delhi Transport Corporation - DTC Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date11 Feb 2025
Closing Date20 Feb 2025
Tender Amount₹ 29,50,747
Costs
EMD
₹ 59,015Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_DTC_268390_1Bid Award Id
ViewTender No
Dy.CGM(Civil)/CED/Elect. /2024-25/35Tender Authority
Delhi Transport Corporation ViewPurchaser Address
-Website
http://http://www.dtc.nic.in/home/delhi-transport-corporation-dtc
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
650
168
109200
... More
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated
copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
300
281
84300
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
-
-
-
... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
500
137
68500
... More
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
125
227
28375
... More
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
250
215
53750
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
-
-
-
... More
5 x 4 sq. mm
300
182
54600
... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
-
-
-
... More
25 mm
300
69
20700
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
-
-
-
... More
5/6 A switch
50
84
4200
... More
15/16 A switch
50
114
5700
... More
3 pin 5/6 A socket outlet
50
81
4050
... More
6 pin 15/16 A socket outlet
50
153
7650
... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
-
-
-
... More
3 Module (100 mmX75 mm)
10
185
1850
... More
6 Module (200 mmX75 mm)
5
258
1290
... More
8 Module (125 mmX125 mm)
5
297
1485
... More
12 Module (200 mmX150 mm)
25
344
8600
... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
80
406
32480
... More
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
457
46
21022
... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
80
288
23040
... More
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
-
-
-
... More
Group C
10
415
4150
... More
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
-
-
-
... More
100 A, 30kA, FPMCCB
6
5360
32160
... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
-
-
-
... More
12-way, Double door
2
1151
2302
... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
-
-
-
... More
6 way (4 + 18), Double door
6
2659
15954
... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
-
-
-
... More
4 way (4 + 12), Double door
2
4502
9004
... More
8 way (4 + 24), Double door
1
5664
5664
... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
... More
Single pole
108
173
18684
... More
Triple pole
16
700
11200
... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
... More
63 A
1
2242
2242
... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
... More
63 A
6
2302
13812
... More
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A, 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
6
627
3762
... More
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
6
980
5880
... More
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A, "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
12
2488
29856
... More
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
8
3672
29376
... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
150
129
19350
... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required.
100
23
2300
... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required.
-
-
-
... More
Upto 35 sq. mm (clamped with 1mm thick saddle)
800
25
20000
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
-
-
-
... More
4 X 16 sq. mm (28mm)
2
255
510
... More
Supply of XLPE insulated PVC Sheathed Armoured Aluminium Conductor cable 1.1KV Grade Conforming to IS-7098 of size 4x16 Sq. mm.
800
356
284800
... More
S/I/T/C of LED Fitting 20 watt 6500k
290
373
108170
... More
S/I/T/C of led panel 36 watts 2'X2' 6500K
16
2171
34736
... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
80
2730
218400
... More
S/I/T/C of LED flood Light 50 watt exclusive innovative die-cast aluminium IP66, 120 lm/W flood light with lens
4
4392
17568
... More
S/I/T/C of LED flood light fitting 100 watt IP -66, 120 lm/W protection with lens
16
5928
94848
... More
S/I/T/C of LED flood light fitting 250 watt IP -66, 120 lm/W protection with lens
18
17564
316152
... More
S/I/T/C of 380mm Exhaust fan heavy duty 1400 RPM single phase
8
4364
34912
... More
S/I/T/C of 300mm Exhaust fan heavy duty 1400 RPM single phase
10
3772
37720
... More
S/I/T/C of 600mm Industrial Wall fan 1440 RPM single phase
15
9790
146850
... More
Supplying, fixing and Installing of 63A TPN rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Three poles and Neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required.
4
2477
9908
... More
S/I/T/C of LED High Bay Flood Light 100 watt IP66 robust highbay LED with PDC housing suitable for ceiling (Surface/Suspended) mounting with system efficacy ? 150 lm/W.
30
10873
326190
... More
Dismantling work of old defective electrical installations (including cable, DB, wiring etc).
1
10000
10000
... More
Repairing of DG panel
1
15000
15000
... More
Servicing of LT Panels and Main Distribution Panels (Cleaning, Painting, megger testing & other requirements as per site).
1
10000
10000
... More
Salvage value of old defective ceiling fan
60
500
-30000
... More
(Total + Add prevailing cost index @ 31.27% On DSR-2016 rate)
1107323
-
346259.9
... More
@9.5% below on (Total + Add prevailing cost index @ 31.27% on DSR-2016 rate)
1453582.9
-
-138090.38
Evaluation Notes How It Works ?
Potential Partner