Delhi Transport Corporation Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Delhi Transport Corporation - DTC Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date23 Jun 2022
Closing Date12 Jul 2022
Tender Amount₹ 29,85,816 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

960

-

281

... More
Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.

-

-

-

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

400

-

137

... More
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire

400

-

215

... More
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.

-

-

-

... More
1 Pair

20

-

15

... More
2 Pair

20

-

19

... More
4 Pair

1600

-

28

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
20 mm

400

-

57

... More
25 mm

800

-

69

... More
32 mm

600

-

89

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

-

-

-

... More
5/6 amp switch

100

-

84

... More
15/16 amp switch

100

-

114

... More
3 pin 5/6 amp socket outlet

100

-

81

... More
6 pin 15/16 amp socket outlet

100

-

153

... More
Telephone socket outlet

20

-

96

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required

100

-

24

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

70

-

288

... More
Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular switches in recess etc as required.

-

-

-

... More
1 or 2 Module (75mm X 75mm)

12

-

175

... More
6 Module (200mm X 75mm)

12

-

258

... More
12 Module (200 mmX150 mm)

50

-

344

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.

100

-

406

... More
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.

-

-

-

... More
Group C

160

-

415

... More
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.

-

-

-

... More
125 A, 36kA, FPMCCB

2

-

5449

... More
100 A, 16 kA,TPMCCB

8

-

3218

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)

-

-

-

... More
6 way (4 + 18), Double door

6

-

2659

... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)

-

-

-

... More
4 way (4 + 12), Double door

2

-

4502

... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Single pole

72

-

173

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

20

-

7

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
63 A

18

-

2242

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
63 A

6

-

2302

... More
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.

2

-

3672

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

100

-

129

... More
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.

4

-

304

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For Horizontal run)

250

-

66

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)

200

-

100

... More
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and pring washers etc. complete as required.

50

-

73

... More
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.

150

-

112

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.

-

-

-

... More
Upto 35 sq. mm

150

-

206

... More
Above 35 sq. mm and upto 95 sq. mm

50

-

214

... More
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required.

-

-

-

... More
Upto 35 sq. mm

100

-

141

... More
Upto 35 sq. mm

-

-

-

... More
Upto 35 sq. mm (clamped with 1mm thick saddle)

150

-

25

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.

-

-

-

... More
3½ X 50 sq. mm (35 mm)

4

-

354

... More
4 Core 25 Sqmm

24

-

258

... More
Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.

-

-

-

... More
4 Core 25 Sqmm

8

-

1415

... More
Supplying and fixing 1000 mm x 900 mm wide checkered rubber matting conforming to IS 5424- 1969 complete as required.

-

-

-

... More
1100 V grade size 1000 x 900 x 15 mm thick

2

-

1307.05

... More
Supplying & fixing standard shock treatment charts in English & Hindi duly framed and covered with glass.

2

-

384.43

... More
Supplying and erection of the following equipment at suitable locations in the substation building as required and as per specifications.

-

-

-

... More
2 kg DCP with CO2 gas cartridge fire extinguisher (conforming to IS:2171 with cylinder fully charged).(MMX CO2 2 Kg IS:15683 (Wheel Type) (Fire Rating 21B )

2

-

7139.34

... More
Supplying and installing at approved location approved make 4 nos. fire buckets of 24 gauge galvanized steel, painted white inside and red outside and black on the bottom, inscribed with letters "FIRE" in black and gold including stand fabricated out of sheet metal (16 gauge) shade, platform and associated civil works, painting etc as approved by fire authority.

2

-

1273

... More
Providing first aid box as per IS:2217.

1

-

1647.54

... More
Design, manufacture, supply, installation, testing and commissioning of following Utility panels suitable for 415 V, 3 phase, 4 wire, 50 Hz power distribution system. The panel shall be Indoor, free standing, floor mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalized design fabricated out of 2mm thick CRCA sheet steel for Load bearing members and 1.6 mm thick for non-load bearing members, complete with colour coded, heat shrinkable PVC insulated, aluminium bus bars and separate earth bus bar of adequate cross section throughout the length of the panel. The incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber (form-3b Construction). The panel shall be complete with name plate, earthing, numbering, danger plate etc. as required and as per specifications and drawings. The panel shall withstand the fault level of as indicated elsewhere or shown in Single Line Diagram. Important Notes: Common for all Switchboard: The BOQ shall be read inconjunction with general notes, specification and Single Line Diagram (attached for Ref.). Incase of any discrepancy between specification, BOQ and SLD, the same shall be brought to the notice of Client/Consultant before quoting the rates, otherwise stringent condition shall be deemed to have been considered. Fault current wherever mentioned shall be Ics value. (Ics = 100% Icu). All MCCB shall be provided with door interlocked rotary handle with ON/TRIP/OFF position indicator, continious variable thermal magnetic O/C and S/C releases. All rating MCCB's shall be thermalmagnetic type. Incoming MCCBs shall be provided with O/C, S/C, and Earth fault protection releases. Outgoing MCCBs shall be provided with O/C, short circuit protection. All feeder doors shall have pad locking arrangement. All TP feeders shall have solid isolable neutral link. All MCCB used in starter feeder shall be suitable for motor duty application. All power contactors including NIC shall be of AC3 duty. All switchgear used in starter feeder shall be type-2 co-ordinated. Manufacturer is required to submit manufacturers type-2 co-ordination chart for the make used. All meters are digital type. Panel shall be powder coated of approved shade with minimum 60 micron thickness. ACB's/MCCB's in one particular panel shall be of one similar make. Size of Voltmeter / Ammeter for incomer also, 96mm x 96mm flush mounted with shrouded terminal shall be used in the panel. Bus bar chamber shall be kept at top of the all panels. All bus bar shall be insulated with coloured PVC Sleeve i.e.RYB,BK as per colour code. Internal wiring of panel shall be with size 2.5sqmm Flexible Copper Conductor for CT circuit and control wiring with 1.5 sqmm. All Lift Panels transport section should not be more then 1000 mm. In soft starter Vender should supply power contactor with aux. Contactor & All necessary accessories required etc. (As per BOQ & specification ) All indicating light shall be LED type . Each vertical section of floor mounted panel shall have independent base frame (75mm x 40mm) size made out of 3 mm sheet steel (LT Panel & DG Panel). All the makes shall be as per Client approved make list only. Wherever only voltmeter & ammeter are required, the same may be provided in combined meter suitable for both parameter. Two (2) Nos. 400 A FP MCCB . One (1) No. digital multifunction meter for measurement of voltage and currents with selector push buttons (ELF-3259 of conzerv or equivalent) and one set of CTs of ratio 400A /5A, CL 1.0, 15 VA. 3 Nos. phase indication lamps and 3 Nos. status indication lamps for ON/OFF/ Trip with control SP MCB. Busbar : 800A TPN Al. Busbar of short circuit withstand capacity 35kA. Busbar shall be insulated with heat shrinkable sleeves and shall be color coded. Outgoing : All MCCB outgoing feeders shall be of 35 kA breaking capacity and shall be provided with ON/OFF / Trip indication lamps with back up SP MCB. Four (4) Nos. 125A FP MCCB Four (4) Nos. 100A FP MCCB

-

-

-

... More
MDB described as above.

1

-

261750

... More
Supply installation, testing and commissioning of following sizes of PVC sheathed XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade on surface of wall or in existing cable tray /masonary ducts/GI pipe with fixing hardware etc as required. Aluminium Conductor XLPE Armoured Cables:

-

-

-

... More
Supply 4 core 25 sqmm

200

-

228

... More
Supply 3.5 core 50 sqmm

50

-

461

... More
Supply, laying, installation, testing and commissioning of Tagblock in wall recessed / surface mounted.

-

-

-

... More
10 Pair

1

-

711.5

... More
Supplying and fixing following modular switch/ socket with modular plate & switch box including connections etc. as required.

-

-

-

... More
RJ-45 cat-6

25

-

810.35

... More
Supply and drawing of cat 6 Data cable in existing conduit as require.

640

-

43.22

... More
Supply, receiving, storing, handling, assembling in position the following light fixtures including lamps as described below complete with all accessories, control gear as required at site.

-

-

-

... More
15W LED 300x300mm SQUARE LIGHT

59

-

1153.28

... More
15W LED CEILING LIGHT

99

-

1318.03

... More
Ceiling Mounted Fans (1200mm Fan)

55

-

2041

... More
10W LED CEILING LIGHT (TOILET)

40

-

849

... More
20 W Tube Light

24

-

457

... More
10 W Mirror Light

8

-

325.11

... More
Exhaust Fan (225 mm Air Flow ) or EQUIVALENT

12

-

2218.69

... More
Providing, laying, Testing & commissioning of C-class heavy duty MS pipes confirming to IS 3589/1239 including welding ,fittings like elbows, Tees, Flanges, tapers, nuts bolts, gaskit etc. Fixing the pipes with suitable clamp/support and painting with two more coats of synthetic enamel paint of required shade as required

-

-

-

... More
80 mm dia

52

-

1122

... More
100 mm dia

6

-

1499

... More
Supply & Fixing of Single Headed Internal hydrant Valve with instantaneous gunmetal/stainless steel coupling of 63 mm dia with cast iron wheel ISI marked confirming to IS 5290 with blank Gun metal/stainless steel Cap and chain as required.

-

-

-

... More
Single headed Gun metal

2

-

7494

... More
Supply, Fixing, testing & commissioning of Butterfly valves of PN 1.6 rating with bronze/gun metal seat duly ISI marked complete with nuts, bolts, washers, gasket confirming to IS 13095.

-

-

-

... More
100 mm dia

2

-

6454

... More
Supply, Fixing, testing & commissioning of Non return valves complete with nuts, bolts, washers, gasket confirming to IS 5312

-

-

-

... More
100 mm dia

1

-

10836

... More
Supply, Fixing, testing & commissioning of Stainless Steel Y-strainer fabricated out of 1.6 mm thick stainless steel grade 304 sheet with 3 mm dia holes with stainless steel flanges

-

-

-

... More
100 mm dia

1

-

6450

... More
Supply& Fixing of 63 mm dia ,15 m long RRL hose pipe with 63 mm dia male and female coupling duly wind with GI wire confirming to IS 636 ( Type-A)

-

-

-

... More
Gun metal

4

-

5188

... More
Supply& Fixing of First-Aid Hose Reel with MS construction spray painted in Post office Red confirming to IS 884 complete with 20 mm water hose thermoplastic IS 12585

-

-

-

... More
30 mtrs

2

-

8413

... More
Supply& Fixing of 63 mm dia gun metal short branch pipe with 20 mm nominal internal dia size nozzle confirming to IS 903

-

-

-

... More
Gun metal

2

-

2402

... More
Providing & fixing of Air vessel 250 mm dia ,8 mm thick MS sheet,1200 mm height with air release valve on top.

1

-

1350

... More
providing & fixing of Pressure switch in MS line including connection

1

-

1508

... More
DCP-4.5 kg

6

-

2700

... More
CO2-4.5 kg

6

-

4800

... More
Supply, Installation, testing & commissioning electric driven Terrace pump suitable for automatic operation & complete in all respect.

1

-

85291

... More
Fire Panel

1

-

24700

... More
Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.

4

-

462

... More
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.

4

-

545

... More
supply, installation, testing & commissioning of fire Control Module

4

-

2990

... More
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.

1

-

8468

... More
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.

115

-

141

... More
Laying & Fixing of PVC insulated and PVC sheathed power cable 1.1 KV grade

200

-

39

... More
Adding 15% contractor profit on MR total 785822.88 from S. No. 33 to 42.7

785822.88

-

0.15

... More
DSR-2016 Total from S. No 1 to 32.1

1549877

-

0.23

... More
Rate -@9.5% below on DSR-2016+Add prevailing cost index @ 22.69%

1901544.09

-

0.1



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.