Delhi Transport Corporation Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Delhi Transport Corporation - DTC Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date26 Jul 2024
Closing Date8 Aug 2024
Tender Amount₹ 20,36,714
Costs
EMD
₹ 40,735Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DTC_260150_1Bid Award Id
ViewTender No
Dy.CGM(Civil)/CED/Elect. /2024-25/07Tender Authority
Delhi Transport Corporation ViewPurchaser Address
-Website
http://http://www.dtc.nic.in/home/delhi-transport-corporation-dtc
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
150
42150
281
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
-
-
-
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
150
20550
137
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
150
32250
215
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required.
-
-
-
Group C
50
22600
452
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
-
-
-
3 x 1.5 sq. mm
50
2500
50
5 x 4 sq. mm
200
36400
182
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface /recess including cutting the wall and making good the same in case of recessed conduit as required.
-
-
-
25 mm
250
17250
69
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
-
-
-
5/6 A switch
50
1700
34
15/16 A switch
50
3750
75
3 pin 5/6 A socket outlet
50
2100
42
6 pin 15/16 A socket outlet
50
4300
86
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
50
14400
288
Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 A & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
50
14350
287
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
240
11040
46
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
-
-
-
Group C
40
16600
415
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
-
-
-
100 A, 30kA, FPMCCB
2
10720
5360
125 A, 36kA, FPMCCB
1
5449
5449
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator)
-
-
-
4 way (4 + 12), Double door
2
4396
2198
6 way (4 + 18), Double door
2
5318
2659
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)r)
-
-
-
4 way (4 + 12), Double door
2
9004
4502
8 way (4 + 24), Double door
1
5664
5664
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
Single pole
60
10380
173
Triple pole
16
11200
700
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
63 A
4
9208
2302
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A, “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and
complete with connections, testing and commissioning etc. as required.
15
37320
2488
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
6
22032
3672
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
3
255
85
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
80
10320
129
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering.
-
-
-
Above 35 sq. mm and upto 95 sq. mm
200
21200
106
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required.
-
-
-
Upto 35 sq. mm (clamped with 1mm thick saddle)
200
5000
25
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
-
-
-
4 X 25 sq. mm (28mm)
16
4128
258
3½ X 70 sq. mm (38mm)
6
2364
394
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level)including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
-
-
-
90 mm dia (OD-90 mm & ID-76 mm nominal)
200
32600
163
Supply of XPLE insulated PVC sheathed Armoured AL conductor cable 1.1 KV grade conforming to IS-7098 of size 4X25 sq. mm.
200
93400
467
Supply of XPLE/PVC insulaed PVC sheathed armored cables with aluminum conductor 3.5X70 sq. mm.
200
201400
1007
S/I/T/C of LED flood light fittings 1X100 Watt IP - 66
18
113508
6306
S/I/T/C of LED flood Light 200 watt exclusive innovative die-cast aluminium IP66 flood light
9
75024
8336
S/I/T/C of LED High Bay Flood Light 100 watt IP66 robust highbay LED with PDC housing suitable for ceiling (Surface/Suspended) mounting with system efficacy upto 150 lm/W.
18
107892
5994
S/I/T/C of LED flood light fittings 1X60 Watt IP - 66
25
104675
4187
S/I/T/C of complete LED Tube fitting 20 watt
100
38500
385
S/I/T/C of 48'' Ceiling fan High Speed
50
143500
2870
S/I/T/C of 600mm Industrial Wall fan 1440 RPM single phase
11
156728
14248
S/I/T/C of Exhaust fan 15" (1400RPM)
4
22456
5614
Dismantling and Shifting work of old/existing electric fittings in maintenance shed, workshop shed, etc as required.
1
5000
5000
Labour charge for lowering and lifting of flood lights of fixed type tower
2
2000
1000
L.T Panel, for Admin block
Design, manufacture, supply, installation, testing and commissioning of following Utility panels suitable for 415 V, 3 phase, 4 wire, 50 Hz power distribution system. The panel shall be Indoor, free standing, floor mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalised design fabricated out of 2mm thick CRCA sheet steel for Load bearing members and 1.6 mm thick for non-load bearing members, complete with colour coded, heat shrinkable PVC insulated, aluminium bus bars and separate earth bus bar of adequate cross section through out the length of the panel. The incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber (form-3b Construction). The panel shall be complete with name plate, earthing, numbering, danger plate etc. as required and as per specifications and drawings. The panel shall withstand the fault level of as indicated elsewhere or shown in Single Line Diagram.
Important Notes: Common for all Switchboard:
The BOQ shall be read inconjunction with general notes, specification and Single Line Diagram (attached for Ref.). Incase of any discrepancy between specification, BOQ and SLD, the same shall be brought to the notice of Client/Consultant before quoting the rates, otherwise stringent condition shall be deemed to have been considered.
Fault current wherever mentioned shall be Ics value. (Ics = 100% Icu).
All MCCB shall be provided with door interlocked rotary handle with ON/TRIP/OFF position indicator, continious variable thermal magnetic O/C and S/C releases. All rating MCCB's shall be thermalmagnetic type.
Incoming MCCBs shall be provided with O/C, S/C, and Earth fault protection releases.
Outgoing MCCBs shall be provided with O/C, short circuit protection.
All feeder doors shall have pad locking arrangement.
All TP feeders shall have solid isolable neutral link.
All MCCB used in starter feeder shall be suitable for motor duty application.
All power contactors including NIC shall be of AC3 duty.
All switchgear used in starter feeder shall be type-2 co-ordinated. Manufacturer is required to submit manufacturers type-2 co-ordination chart for the make used.
All meters are digital type.
Panel shall be powder coated of approved shade with minimum 60 micron thickness.
ACB's/MCCB's in one particular panel shall be of one similar make.
Size of Voltmeter / Ammeter for incomer also, 96mm x 96mm flush mounted with shrouded terminal shall be used in the panel.
Bus bar chamber shall be kept at top of the all panels.
All bus bar shall be insulated with coloured PVC Sleeve i.e.RYB,BK as per colour code.
Internal wiring of panel shall be with size 2.5sqmm Flexible Copper Conductor for CT circuit and control wiring with 1.5 sqmm.
All Lift Panels transport section should not be more then 1000 mm.
In soft starter Vender should supply power contactor with aux. Contactor & All necessary accessories required etc. (As per BOQ & specification )
All indicating light shall be LED type .
Each vertical section of floor mounted panel shall have independent base frame (75mm x 40mm) size made out of 3 mm sheet steel (LT Panel & DG Panel).
All the makes shall be as per Client approved make list only.
Wherever only voltmeter & ammeter are required, the same may be provided in combined meter suitable for both parameter.
Incoming:
One (1) Nos. 250 A FP MCCB, 36 kA thermal megnatic release
One (1) No. digital multifunction meter for measurement of voltage and currents with selector push buttons (ELF-3259 of conzerv or equivalent) and one set of CTs of ratio 250 /5A, CL 0.5, 15 VA.
3 Nos. phase indication lamps and 3 Nos. status indication lamps for ON/OFF/ Trip with control SP MCB.
Busbar :
300A TPN Al. Busbar of short circuit withstand capacity 36kA. Busbar shall be insulated with heat shrinkable sleeves and shall be color coded.
Outgoing :
All MCCB outgoing feeders shall be of 25 kA breaking capacity and shall be provided with ON/OFF / Trip indication lamps with back up SP MCB.
One (1) Nos. 160A FP MCCB
One (1) Nos. 125A FP MCCB
Five (V) Nos. 100A FP MCCB.
MDB described as above. (CPRI Approved)
1
230256
230256
(+) Add prevailing cost index @ 31.27% On DSR-2016 Amount
624898
195405
0.31
(-)@9.5% below on (DSR-2016 Rate+Add prevailing cost index @ 31.27%) (624898.00 + 195405.60)
820303.6
-77928
0.1
Evaluation Notes How It Works ?