Delhi State Industrial And Infrastructure Development Corporation Limited Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Delhi State Industrial And Infrastructure Development Corporation Limited - DSIIDC Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date8 Feb 2024
Closing Date19 Feb 2024
Tender Amount₹ 26,38,882
Costs
EMD
₹ 52,800Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DSIDC_253517_1Bid Award Id
ViewTender No
NIT No-02/23-24 (Recall)Tender Authority
Delhi State Industrial And Infrastructure Development Corporation Limited ViewPurchaser Address
-Website
http://http://www.dsiidc.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc. as required
i) 80 mm dia
2
-
-
ii) 150 mm dia
1
-
-
Supplying and fixing single headed internal hydrant valve with instantaneous Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Stainless Steel cap and chain as required.
i) Single headed Stainless Steel
2
-
-
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type pendant sprinklers of rating 68 degree centigrade with required accessories.
i) Single headed Stainless Steel
10
-
-
Dismantling of existing unworkable ML-4 contactor from starter, disconnection from existing control wiring, providing & fixing L & T make ML-4 contactor i/c re-connection all the wiring complete as reqd. i/c dismantle will be property of contractor.
2
-
-
Providing & fixing 100 mm dia pressure gauge on M.S. pipe line including connection etc. as required. The scope of work include dismantling of existing pressure gauge from pipe line with credit of dismantle pressure gauge to agency.
8
-
-
Reconditioning of the Diesel Engine Set of 75 KVA i/c dismantling from the location, overhauling checking, servicing, greasing and re-fixing the internal defective parts etc as reqd i/c re-testing & commissioning etc complete as reqd fire filter with assembly-02 nos, oil filter-1 set, mobile oil 20 ltr self repairing, nozzle repairing, diesel-40ltrs complete as reqd i/c dismantle will be property of contractor.
1
-
-
Reconditioning of Elect. driven main fire pump set / DG pump having a discharge of 2850 LPM at 70 mtr head include dismantling from the location, checking servicing, greasing and re-fixing the same after effecting necessary repairs of internal defective parts and replacement of the following parts shaft and mechanical seal etc sleeves-6, gasket-3 etc complete as reqd. all the dismantle will be property of contractor.
2
-
-
S/I/T/C of 180 AH, 12 Volt lead acid battery complete with cable terminals, battery lead etc i/c connection, inter connection etc existing diesel engine fire pump complete as reqd i/c dismantle battery will be property of contractor.
2
-
-
Replacement of existing unworkable battery charger, 24 volt, 10 amp i/c dis-connection, re-connection etc complete as reqd. The dismantle battery charger will be property of contractor.
1
-
-
Providing & fixing shut off nozzle for existing fire fighting pipe i/c testing etc complete as reqd.
10
-
-
Supplying and fixing 63 mm dia, stainless steel, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required.
8
-
-
Supplying & fixing 63 mm dia stainless steel short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required.
10
-
-
Refilling of ABC Stored Type Fire Extinguisher Filled with mono ammonium Phospate Dry Chemical ABC Powder complete with specifications
Capacity 6 KG
40
-
-
Refilling of CO2 type Fire Extinguisher Complete as required, Capacity 4.5 KG
40
-
-
Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required.
2
-
-
S/I/T/C of 65 AH, 12 Volt lead acid battery complete with cable terminals, battery lead etc i/c connection, inter connection etc existing diesel engine fire pump complete as reqd i/c dismantle battery will be property of contractor.
2
-
-
Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface
/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
5
-
-
Providing & fixing fire alarm hooter on existing wall i/c connection etc complete as reqd.
5
-
-
Supplying, installation, testing & commissioning of smoke detector with built in LED and mounting base complete with all connections etc. as required.
20
-
-
Supplying & laying of 2x1.5 sq mm fire alarm armored cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armoring & FRLS outer sheath complete as required.
20
-
-
Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required.
10
-
-
Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required.
10
-
-
Repairing of existing unworkable main fire alarm panel having 24 zone, dismantling of all existing control wiring, wiring the same, dismantling of various card / line and re- fixing the same after repair, enabled the supply of speaker, checking supply of all zone, replacement of existing worn-out LED indication lamp, the scope of work included all material which require for start the panel. Dismantle accessories will be credited to contractor.
1
-
-
(A) Supply, Installation, Testing and Commissioning of Electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respect, as required: (Jockey Pump)
(B) Horizontal type, multistage , centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS: 1520.
(C) Suitable HP Squirell Cage Induction Motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC Supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class- 'F' insulation, conforming to IS:325.
(D) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.
(E) Suitable cement concrete foundation duly plastered and anti vibration pads. i) 300 lpm at 70m Head
1
-
-
Providing, Laying, Testing & Commissioning of "C" Class heavy duty MS pipe confroming to IS 3589/ IS 1239 including welding, fittings like elbow, tees, flangs, tapers, nut bolts, gaskets etc. and fixing the pipe on the wall/ ceiling with suitable clamp/ support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required
(a) 150 mm
40
-
-
De-Preserving service of 250 Kva DG Set including checking of 250 KVA DG Set of checking of Instrument Panel, Draining Engine Oil and flushing Engine with flushing Oil, Refilling new Oil including the replacement of Oil Filter, Diesel Filter ,Pre-filter etc. as required.
1
-
-
De-Preserving service of 500 Kva DG Set including checking of 500 KVA DG Set of checking of Instrument Panel, Draining Engine Oil and flushing Engine with flushing Oil, Refilling new Oil including the replacement of Oil Filter, Diesel Filter ,Pre-filter etc. as required.
1
-
-
Servicing of Heat Exchanger and replacement of Coolant including draining of Heat Exchanger, Flushing, Re-fitting coolant as required.
2
-
-
Replacement of connecting Hoses Pipe and Screws as may be as required.
2
-
-
Servicing of existing Cooling Tower including cleaning, flushing of cooling tower and replacement of minor material parts and testing of standalone system complete in all respect.
2
-
-
S/I/T/C of 3.7 KW 4 Pole 415 V, 3 Phase Motors for Cooling Mechanism of DG Sets.
5
-
-
Servicing of water circulating pumps, Re-flushing the same complete in all respect.
5
-
-
Replacement of Cooling Tower/ motor/Servicing and re-winding of motor as may be required.
1
-
-
Replacement of circulating water pump as may be required.
1
-
-
Refurbishing of complete cooling tower including shifting on new foundation piping connections etc. as required
1
-
-
Repair of motor and fan of cooling tower.
2
-
-
Providing and laying & wiring of aluminum armored copper control cable of :
i) 25 sq mm x 3.5 core.
40
-
-
Providing controllers with programmable logic control for DG sets including wiring etc. as required
2
-
-
Refurbishing of the control panels starters for cooling tower motors
2
-
-
Refurbishing of control panel pump starters for water circulating pumps.
5
-
-
Providing Coolant & service of Heat Exchanger
2
-
-
Diesel Storage Tank Cleaning Reconnection & re-fixing
2
-
-
Exhaust pipe cleaning and decarbonisation
2
-
-
S/IT/C of Batteries of 500 KVA & 250 KVA DG Genset, Capacity of Battries 180Ah 12 V
4
-
-
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as
required.
4 Pair
200
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Telephone socket outlet
10
-
-
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
1 run of cable
200
-
-
SITC of Digital Signal Processor with 2 x XLR IN, electronically balanced audio input,6 x XLR OUT, electronically balanced audio output with 2 x XLR Thru out ,and 1x XLR AES/EBU IN digital input,with Nominal Input Voltage:1.23V / +4 dBu, maximum input voltage:8.7V / +21 dBu,input impedence :10k Ohm,CMR:-80dB@1kHz,A/D &D/A coversion :24 bit sigma delta,THD+N 0.01%
1
-
-
SITC of class H dual channel amplifier 2x800W at 4ohm, THD0.03%, Crosstalk-80dB, Frequency response @ 10Hz to 40kHz, Signal to Noise ratio106dB, inbuilt Audio limiters, High temperature, DC, HF, Back-EMF, Peak current limiters, Inrush current limiters, Turnon delay
1
-
-
SITC of class AB dual channel amplifier 2x500W at 4ohm, THD0.03%, Crosstalk-80dB, Frequency response @ 10Hz to 40kHz, Signal to Noise ratio106dB, inbuilt Audio limiters, High temperature, DC, HF, Back-EMF, Peak current limiters, Inrush current limiters, Turnon delay
1
-
-
SITC of 16 channel mixer with 16 line inputs(8 mono, 4 stereo), 10 mic input with 48V phantom power, Digital effects processors: 24 “SPX” effects, 24-bit/92kHz 2IN/2OUT USB Audio Interface function, THD @ 0.03%, Frequency response @ 20Hz to 48kHz, Crosstalk @ -78dB
1
-
-
SITC of 5m microphone patch cords complete with connector assembly set
15
-
-
Repairing & Servicing of fixed Bullet IP Camera, IR LED; 5x24 PCS; 20M, board lens ; 3.6 mm, water resistiance: IP66, Anticut Universal ball joint etc. complete in all respect as required at site.
7
-
-
Repairing & Servicing of vandal proof IR Dome Camera, IR LED 5x24 PCS; 20M,LEN ;3.6 mm, with deep base add USD3 ETC. Complete in all respect as reqd.
6
-
-
Repairing & Servicing of 16 Channel NVR H.264 Main processor H3565 with network backup complete in all respect as reqd.
1
-
-
S/I/T/C Cat-6 UTP cable
300
-
-
S/I/T/C Cat-6 UTP cable patch cord 1 mtr long
13
-
-
S/I/T/C RJ45 Connectors Dlink for NVR POE switch board etc as required
13
-
-
Programing & Software installation including servicing of network system
1
-
-
Dehydration of 11 KV(Voltamp make), 750 KVA Transformer oil i/c filtration at the site with the help of dehydration of machine i/c testing of dielectric strength of transformer oil before & after the dehydration etc complete as reqd
555
-
-
Dehydration of 11 KV(Servokon make),750 KVA Transformer oil i/c filtration at the site with the help of dehydration of machine i/c testing of dielectric strength of transformer oil before & after the dehydration etc complete as reqd.
630
-
-
Supplying and filing of transformer oil (ISI mark) in the existing transformer & topping / replacement i/c testing of dielectric strength of the transformer oil after refilling complete as reqd.
100
-
-
Replacement of existing silicon breather pot complete with nipple reducer for fixing the transformer complete as reqd.
2
-
-
Testing of 11KV/440 Volt transformer after disconnection of HT cable, LT Bus trunking with HT megger , transformer testing equipments & surge supply i/c testing of magnetic current ,IR value of HT & LT winding of transformer etc as reqd.
2
-
-
Servicing of existing bus-bar of HT Panel (main incomer and 02Nos main out going ) feeding from main supply, after disconnection / dismantling of all existing bus-bar and re-assembling of all bus-bar with checking, testing, tightening of nut-volts, reconnection with panel and testing commissioning etc as reqd.
1
-
-
Painting of existing main incomer and main out going panel from inside with double coat epoxy paint i/c removing of existing moisture with hot blower , removing of existing dust and rust particular complete as reqd.
3
-
-
Testing of existing main incomer/ out going cable , VCB , bus-bar chamber with the help of testing kit i/c high voltage test up to 17.5 KV, complete as reqd.
1
-
-
Servicing of Thee phase 11KV, 630 AMP capacity H.T. VCB , Crompton make opening the required parts for servicing, checking, cleaning, testing and rectification of defect, oiling, greasing, moving gear assembly and ARC contact with CR 2 spray and Cadmium solution i/c reassembling re-commissioning in the H.T. panel etc as reqd.
3
-
-
Calibration & testing of relays having 2 nos. over load relays and one no. Earth fault relay in the existing HT panel by secondary injection method cleaning the contacts resetting with reqd. accuracy complete checking & setting of complete wiring i/c fixing of the relay unit etc complete as reqd.
3
-
-
Servicing of 11KV/110volts PT complete i/c removal of the PT from the HT panel board cleaning of dirt particles, soaking the moisture, tightening the connection i/c checking of the top cover assembly, testing and commissioning etc as reqd.
1
-
-
Replacement of existing damaged / unworkable 11KV, 100/50/5/5 (HT) & 50/25/5/5 (LT) amp. CT complete i/c removal of the CT from the HT panel board cleaning of dirt particles, soaking the moisture, tightening the connection , checking of the top cover assembly, testing , commissioning etc as reqd.
1
-
-
Replacement of existing damaged / unworkable following HT /LT Electrical accessories from main incomer and main out going panel i/c testing etc complete as reqd.
(a) bus-bar insulator
26
-
-
(b) bus-bar spout insulator
18
-
-
(c) bus-bar PT Bush
3
-
-
Disconnection of existing power pack installed in existing HT panel and providing reliable make 24 volt power pack, with 02Nos battery back-up i/c connection of existing indicators complete as reqd.
1
-
-
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
10
-
-
Providing and replacement following LED indicator Light in HT/LT panel i/c connection etc complete as reqd.
(a) 24 volt indicator
9
-
-
(b) 110 volt indicator
3
-
-
Evaluation Notes How It Works ?
Potential Partner