Delhi State Industrial And Infrastructure Development Corporation Limited Tender

... More
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Delhi State Industrial And Infrastructure Development Corporation Limited - DSIIDC Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date27 Feb 2025
Closing Date5 Mar 2025
Tender Amount₹ 3,81,456 
Notes
Download

Costs

Summary

Nw-c/o Academic Building, Fashion Centre And Hostel At Nift, Hauz Khas, Delhi. Sh-providing And Fixing Of 123mm Thick Two Hour Fire Rated Dry Wall To Separate Of Basement And Ground Level Staircase And C/o Fire Control Room In Common Mess Area.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.

247.2

22

5537.28

... More
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.

20

120

2411

... More
Charges of disposal C&D waste at approved dumping ground (which will be reimbursed to the contractor on receipt of orgional invoice).

20

304

6080

... More
Providing and Fixing of Hollow metal door at all levels from ISO 9001-2000 certified Manufacturer. Pressed Galvanised steel Single /Double leaf to required sizes which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277 with or without View Glass. Door frame shall be Single rebate profile of size 100 x 58 mm made out of 1.20 mm thick galvanised steel sheet (18 gauge). Frames should be Mitered and field assembled with self tabs.Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement slurry if recommended. Door leaf shall be 47 mm thick fully flush double skin door with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door shall have reinforcements for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware. The edges should be interlocked with lock seam. For pair of doors astragals will be provided as required. View Glass of various sizes as shown in Door Schedule shall be provided.The glass should be 5 mm clear toughnened glass.All door shall be factory made and rate shall include installation, hardwares  like hinges, , door closer,Vision Panel 300mmx 200mm, Glass, Pull Handle 22x300MM, Dead bolt with Pincyclinder with BSKO fixed partitation glass coordinator etc. as desired with necessary reinforcement  and direction of Engineer in charge.

4.5

8292

37314

... More
Providing and Fixing Stainless Steel Letters of 316 SS Grade of Thickness 18Guage Fixing with Nescessary SS Screw etc Complete and Sample approved by Engineer Incharge Size =300 mm NAME PLATES

1

1723

1723

... More
Providing and Fixing Stainless Steel Name Plate of 304 SS Grade of Thickness 18Guage with digital engraving & colouring and Fixing with Nescessary SS Screw etc Complete and Sample approved by Engineer Incharge Size =Varies size SIGN PLATES

2

26705

53410

... More
Providing and Fixing Stainless Steel Toilet Sign of 304 SS Grade of Thickness 18Guage with digital engraving & colouring and Fixing with Nescessary SS Screw etc Complete and Sample approved by Engineer Incharge Size =Varies size LED DISPLAY SIGN

2

26705

53410

... More
Providing and fixing of Electric fire safety led signage of acrylic sheet and Fixing with Nescessary SS Screw/chain etc Complete and Sample approved by Engineer Incharge size= 12'' x 6'' in 8 mm RADIUM SIGNAGE FOR FIRE SAFETY

1

3159

3159

... More
Providing and fixing warning sign of ACP sheet digitally printed 3M radium vinyl (No smoking, fire exit, stairs, No horn, and use dust bin.) with Nescessary SS Screw/chain etc Complete and Sample approved by Engineer Incharge . Size: 12 x 6 inch with3mm thick

2

1321

2642

... More
Providing and fixing Two hour Fire Rated Drywall with estimated STC 52dB which includes Knauf Floor and Ceiling channel (0.55 mm thick, 72mm wide & having two flanges of 30mm each) to the RCC Floor and Slab with 8mm Dia 40mm long Fasteners @ 600 mm c/c. Wall Studs (0.55 mm thick, 70mm wide having one flange of 34mm another of 36 mm) are placed at 610 mm centres in Floor and Ceiling channel. Provide 70x0.50x695mm thick Knauf Noggin Channel behind Horizontal Board Joints with the help of 4.2x13mm wafer head metal to metal screws. Knauf profiles are rolled with G.I Steel (120 GSM & 230 Mpa Yield Strength) conforming to as per IS 277 Provide 70x0.50x695mm thick Knauf Noggin Channel behind Horizontal Board Joints with the help of 4.2x13mm wafer head metal to metal screws. Provide 50mm thick 48kg density Insulation in the cavity with the help of insulation hold strap fixed @ 1200mm c/c. One layer 12.5mm Knauf Firebloc, conforming to IS 2095(Part 1):2023-Type F and second layer 13mm MULTISTOP ™3 Plasterboard, conforming to (Type D, F, I, R as per BSEN 520) & IS 2095(Part 1):2023-Type R1 & R2, screw fixed either side of Metal Framing with the help of 25 mm long Drywall screws at 300 mm centers The screw fixing of gypsum boards to the metal framing at the periphery, openings and cut edges should be at 150 mm centers All the Plasterboard boards must be staggered All joints to be taped finished with 50 mm wide Paper tape

36.25

3591

130173.75

... More
Providing CO2 High Pressure trolley mounted 9 kg Fire Extinguisher, filled with Co2 Gas as per IS 15222, Gross Weight 36 Kg, empty weight 27 Kg, Control discharge mechanism fitted with 2 Meter Wire Braided Hose & Flat Horn with Diffuser Nozzle for dispersed discharge of CO2, Discharge Time 30 Sec, Average Discharge is 95%, applicable on Class B, C and electrically started Fire, Internal coating is not applicable & External coating is of enamel spray painting, Valve Confirm to IS 3224 ISI Marked, CO2 Cylinder construction: hot spinning by seamless pipes & bearing ISI mark, Body confirms to IS 7285 and PESO APPROVED, Extinguishers confirmed to IS 16018 2012 and ISI maked Fire Rating: 55B

1

10150

10150

... More
Add 31.27% enhancement on DSR

1

21950

21950.79

... More
Less 9.5% enhancement on DSR

1

8754

-8754.1



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.