Delhi State Cancer Institute Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
Refer DocumentsDocument Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_DSCI_207371_1Bid Award Id
ViewTender No
06/EE(E)/DSCI/2021-22Tender Authority
Delhi State Cancer Institute ViewPurchaser Address
-Website
http://http://www.dsci.nic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Above 185 sq. mm and upto 400 sq. mm
320
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following sizeon wall surface as required.
-
-
-
Above 185 sq. mm and upto 400 sq. mm
50
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
-
-
-
Above 185 sq. mm and upto 400 sq. mm
320
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
-
-
-
3½ X 185 sq. mm (57 mm)
4
-
-
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
1380
-
-
SITC of floor mounted cubical panel board of size 900 mm x 1300 mm x 300 mm made of CRCA sheet of 02 mm thick (14 SWG) duly powder coated, dust and vermin proof (CPRI approved IP-54) construction in convenient sections to accommodate following switch gears & accessories suitably with Aluminum Bus Bars of 900A. Capacity, 2 No. earths studs and complete with following accessories. & including necessary copper control wiring for Inter connections, earthing etc. as required. As per direction of Engineer in charge. A. 250 Amp FP MCCB of 35KA, -01 No. B. 160 Amp FP MCCB of 35 KA, -3 nos. C. 63 Amp TPN MCB of 16 KA, - 3 nos. D. 32 Amp TPN MCB of 16 KA, -2 nos. E. Digital Ammeter with CTs ON/OFF/Trip Indication Lamp, (Range - 0 - 500 Ams) - 01 no. F. Digital Voltmeter( range – 0 -500 Volt) - 01 no. G. Digital Voltmeter( range – 0 -500 Volt) - 01 no. H. RYB Phase indicating LED Lamps -3 nos selector switch - 02 nos
2
-
-
Wiring forlight point/fan point/exhaust fan point/call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthling the point with 1.5 sq. mm FR PVC insulated copper conductor single core cable etc. as required.
-
-
-
Group C
16
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required . (Make-Polycab/Havells/Finolex)
-
-
-
3 x 4 sq mm
60
-
-
6 x 4sq mm
40
-
-
Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required(Make- Setia/AKG/).
-
-
-
25 mm
100
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc.
as required.(Make Wipro/Legrand/Carbtree)
-
-
-
6 module
10
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. (Make-Wipro/Legrand/ Carbtree)
-
-
-
5/6 Amp switch
10
-
-
15/16 amp switch
10
-
-
3 pin 5/6 Amp socket
10
-
-
6 pin15/16 amp socket
10
-
-
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator). (make- ABB/Schiender/Legrand)
-
-
-
8 way (4 + 24), Double door
1
-
-
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(make-ABB/ Schiender /Legrand)
-
-
-
Single pole
34
-
-
SITC of 18” Exhaust fan 450 mm, 1400 RPM (Heavy duty industrial type) as per direction of Engineer in charge. (Crompton Greavs /Havels//Usha)
10
-
-
SITC of surface ceiling mount 70 watt flood light as required at site.as per direction of Engineer in charg. (Make-Philips/Havels/Crompton/wipro)
6
-
-
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.(As per CPWD specification) (GI pipe makes -Zindal/Prakash/Apollo)
4
-
-
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.
(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm).
20
-
-
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required
-
-
-
200 mm width X 50 mm depth X 1.6 mm thickness