Delhi Metro Rail Corporation Limited Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Delhi Metro Rail Corporation Limited - DMRC Tender
Civil And Construction
Eprocure
Opening Date12 Mar 2019
Closing Date27 Mar 2019
Tender Amount₹ 1,19,47,078
Costs
EMD
₹ 1,19,471Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_DMRC_454964_1Bid Award Id
ViewTender No
CPM-7/41RTender Authority
Delhi Metro Rail Corporation Limited ViewPurchaser Address
-Website
http://http://www.delhimetrorail.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Made of G.I. wire of dia 4 mm
-
-
561.7
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:
-
-
-
Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
-
-
112.3
Cutting holes upto 30x30 cm in walls including making good the same:
-
-
-
With common burnt clay F.P.S (non modular) bricks
1460
-
219.2
Carriage of materials by manual labour including loading, unloading and staking for lead less than 0.50 KM
-
-
-
Lime, moorum, building rubbish, Rate including upto 9 such additional leads
70
-
-
Carriage of materials by Mechanical Transport including loading, unloading and staking for
-
-
-
Lime, moorum, building rubbish
(lead for 40 Km)
70
-
-
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillers, posts, struts, butresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:
-
-
-
1:11/2:3 (1 Cement:11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size).
70
-
6990.4
Provision for any other DSR 2016 item except above mentioned DSR items.
-
-
-
DESCRIPTION
-
-
-
Providing & fixing brass ball valve with lever. Tested to a pressure of 10 Kg / cm. Including flanges/union, nuts, bolts washer etc Complete as required.
-
-
-
50 mm dia
2
-
-
Providing and fixing C.I. Double flanged Vertical type non return valve of PN 1.6 to 1S:5312 including nut, bolts, 3mm thick compressed asbestose, gasket, companion flanges.
-
-
-
50 mm nominal bore
3
-
-
TUBEWELL AND TUBEWELL PUMPS
-
-
-
Providing and fixing Casing Shoe, well cap clamp and welding complete
2
-
-
Development of tube well to stabilisation and sand free discharge of water with Air compressor complete as per directions of the Engineer.
-
-
-
For a period upto 50 hours.
120
-
-
Providing and fixing single / multistage submersible tubewell pump suitable for 150mm bore with stainless steel casing, NORYL impeller, stainless steel shaft and built in non return valve coupled with submersible squirrel cage motors suitable for 145 V ± 10% volts. 3 phase, 50 cycles AC supply. Capacity 200 1pm
-
-
-
Head 50m , 5.0 HP
2
-
-
50mm dia GI column pipe of Jindal / TT Swastic make heavy class duly flanged.
96
-
-
Providing and fixing gunmetal pressure gauge (100mm dia) of rating (0-10 kg/cm2) with gunmetal isolating cock and connecting pipe.
2
-
-
Providing and fixing 50mm cable clips with nuts & bolts.
100
-
-
Providing and fixing 50mm dia supporting clamps with nuts and bolts.
2
-
-
Providing and fixing 3C - 6 sq.mm submersible cable.
150
-
-
Providing and fixing Butterfly valve of cast body with stainless steel disc and stainless steel stem, teflon bushing and niterite o'rings.
-
-
-
50mm dia
2
-
-
Providing and fixing steel wire rope 6mm dia complete with wire rope clamps for safety of pump set.
100
-
-
Supply, laying, joining, terminating, testing and comssissioning at 1100 v grade armoured FRlSH,XLPE aluminium (AL) Copper (CU) condutor cables on existing trays/.walls/columns indoor including the cost of supports with suitable clamps, saddles, Hooks, bolts etc & in ground / trenches including the cost of proper dressing of cables, markes r providing indentification tags, sand filing etc. (cost of excavation sand & bricks, included here) earthing of glands armouring etc complete as per specification as required and as blelow.
-
-
-
4 Core x 16 sq.mm CU conductor
200
-
-
Providing and fixing dust and vermin proof motor control panel fabricated from 14 SWG MS sheet with stove enamelled paint and comprising of: (for Tubewell pumps)
-
-
-
One feeder of 63 ampere 4 Pole ELCB.
-
-
-
One fully automatic DOL starter with push buttons and indicating lights.
-
-
-
One panel type volt meter 96mm square with Rotary selection switch for reading voltage between phase and neutral or incoming feeder.
-
-
-
Three Neon Phase indicating lights on the incoming Main.
-
-
-
One Ampere meter 96mm square panel type of appropriate range.
-
-
-
Etched plastic identification plates for all switch gears.
-
-
-
Space for liquid level controller.
-
-
-
All internal wiring should be colour coded from incoming main to switchgear, starters, meters, indicating lights. (Compartment light with minimum front area 1.50sqm & 0.30m deep)
12
-
-
Providing and fixing Transistorised liquid level controllers with low voltage Relays and Seamless Steel probes and PVC shroud, including necessary wiring and conduiting from probes to display panel/motor control panels and to provide Audible Alarm for low level for each underground tank. (The cost of all required cabling from probes to Motor control panels to be be including in this rate).
-
-
-
For Domestic over head tank
-
-
-
To start pump at low water level in overhead tank and stop at high water level in overhead tank and low water level in under ground tank.
5
-
-
For Flushing over head tank
-
-
-
To start pump at low water level in under ground tank and stop at high water level in under ground tank.
5
-
-
For Sump Pump
-
-
-
To start Sump pump at High water level in sump and at Low water level in sump
2
-
-
For Borewell
-
-
-
To start pump at low water level in under ground tank and stop at high water level in under ground tank.
3
-
-
Supplying & laying 1.1 KV grade copper conductor PVC insulated cables as required.
-
-
-
3 Core - 1.5sq.mm
2000
-
-
Supplying & laying 1.1 KV grade copper conductor FRLS insulated cables as required.
-
-
-
4 Core - 4sq.mm
500
-
-
Supplying laying testing commissioning of 1.1 KV of FRLS greed XLPE, PVC sheet shed,insulated cu- conductor armoured cables complete as per specification as required in the existing cable tray including on cost of
-
-
-
3 Core - 10sq.mm Copper armoured cable.
600
-
-
Making & Termination copper with double compressor brass gland of XLPE insulated PVC sheathed
25
-
-
Providing and Fixing HILTI mechanical anchor HLC 10*88 bolt for fixing in base plate as per final dawing and as per instruction of Engineer in charge, rate includes all charges for material shifting and making platform for fixing the mechanical anchor bolts.
-
-
126
Total Amount of Schedule-B (NDSR ITEMS) (in Rs.)
-
-
-
Description
-
-
-
Schedule A (DSR-2106 Items)
-
-
-
Schedule B (NDSR Items)
-
-
-
TOTAL QUOTED AMOUNT OF SCHEDULE (A+B) IN FIGURES
-
-
-
TOTAL QUOTED AMOUNT OF SCHEDULE (A+B) IN WORDS ( CONTRACTOR'S TO FILL)
-
-
-
If the tenderer choose to opt At Par under col. 3, then the value in col. 4 in shall be taken as zero percent.
-
-
-
The tenderer shall furnish their rate in terms of % above/below/at par in both schedules A & B.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements