Delhi Jal Board Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Delhi Jal Board - DJB Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date15 Mar 2024
Closing Date22 Mar 2024
Tender AmountRefer Documents
Costs
EMD
₹ 6,500Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DJB_256247_1Bid Award Id
ViewTender No
NIT No 24 (2023-24)Tender Authority
Delhi Jal Board ViewPurchaser Address
-Website
http://http://delhijalboard.nic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supply of 450 mm sweep, Pedestal fan. Make: Orient/ Amonard / Khaitan / Crompton/ CG / USHA (SOR item code-20.5.1)
2
-
-
Supply of 1200 mm sweep ceiling fan. Make: Orient/ Amonard / Khaitan / Crompton / Havells/CG/USHA (SOR item Code-20.1.2)
4
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. DSR 2018Item Code 2.3.1) (6 amp-5 Nos,16 amp-10 Nos,32 amp-10 Nos)
Single pole and neutral
27
-
-
Supplying and fixing 63-amp, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required (SOR 2022-23 ITEM CODE-2.12.2)
Double Pole
5
-
-
Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (DSR Electrical 2018: Item Code 1.14.4)
2 X 6 sq. mm + 1 x 6 sq mm earth wire
100
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular with, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(SOR item code-1.3.3 ( Group C)
55
-
-
Supply and installation of PVC Box having 15 Amp Switch Sockets at each Air Circulator & Exhaust Fan for giving the power supply (DSR 2018 item code- )
17
-
-
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep (DSR Electrical 2018: Item Code 1.50.1) The job also includes fixing the louvers/ shutters complete with frame for an exhaust fan of all sizes. (DSR Electrical 2018: Item Code 1.51)
10
-
-
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. (DSR Electrical 2018: Item Code 1.44)
4
-
-
Installation, testing and commissioning of Air Circulation fan on the wall including providing of the consumables required for the job.
7
-
-
Improvement in Internal Lighting System by carrying out the following works
Supply of Surface and wall mounted 4 feet long, 24 W 6500 K LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver. Make: Osram / Havells / Bajaj / Crompton. (SOR ITEM Code-19.3.1)
30
-
-
Supplying and fixing following piano type switch/ socket on existing switch box/ cover including connections etc. as required. (DSR Electrical 2018: Item Code 1.23)
5/6 A switch
60
-
-
15/16 A switch
20
-
-
3 pin 5/6 A socket outlet
20
-
-
6 pin 15/16 A socket outlet
20
-
-
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. Electrical DSR 2018 : Item No 1.25
4
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. Electrical DSR 2018 : Item No 1.17 2 X 1.5 sq. mm
200
-
-
2 X 2.5 sq. mm
200
-
-
2 X 4 sq. mm
200
-
-
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. (DSR Electrical 2018: Item Code 1.30)
25
-
-
Testing & Commissioning of complete work in the presence of Engineer in-charge with full satisfaction
1
-
-